Article image 2495690000

Weidmueller 2495690000

ACT20P-UI-2RCO-AC-P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ACT20P-UI-2RCO-AC-P
Order No.: 2495690000
Version: Limit value monitoring, universal, Input: temperature, R, U, I, Relay output, 24…230 V AC/DC power supply
GTIN (EAN): 4050118505979
Qty.: 1 pc(s).
Width: 22.5 mm
Width (inches): 0.886 inch
Height: 127.1 mm
Height (inches): 5.004 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 208 g
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: Thermocouples: B, E, J, K, L, N, R, S, T, U, RTD: PT100, PT200, PT1000, Ni120, Cu10, 2-/3-/4-wire
Sensor supply: 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable
Influence of the sensor cable resistance: 5 Ω @ RTD- Kabel
Input voltage: configurable, ±150 mV DC, ± 600mV DC, ±30 V DC, ±300 V DC
Input resistance, voltage: 2 MΩ, > 10 MΩ
Input current: configurable, ± 25 mA DC, ±5 A DC
Input resistance, current: 40 Ω
Cable-length compensation: < ±0.002 Ω per cable resistance Ω
Temperature input range: B: +100…+1820 °C, E: -270…+1000 °C, J: (-210…+1200 °C), K: -270…+1372 °C, L: +100…+900 °C, N: (-180…+1300 °C), R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C
Resistance: 0…10 kΩ, 0…12 kΩ, 0…15 kΩ
Potentiometer: 1.2…500 kΩ
Configuration: With FDT/DTM software, or via 7-segment display, push-buttons and rotary encoder on the device itself
Rail: TS 35
Voltage supply: 90…264 V AC
Alarm function: configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s, Hysteresis adjustable, auto / manual reset
Number of digital outputs: 2
Type: 2 CO contacts, normal / inverse adjustment, Switching frequency 20 Hz
Max. switching voltage, DC: 110 V
Max. switching voltage, AC: 240 V
Rated switching current: 200mA @ 110Vdc, 6A @ 24Vdc / 240Vac
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002654
ETIM 7.0: EC002654
eClass 9.0: 27-21-01-22
eClass 9.1: 27-21-01-22
eClass 10.0: 27-21-01-22
ROHS: Conform
Type: ACT20P-UI-2RCO-AC-P
Order No.: 2495690000
Version: Limit value monitoring, universal, Input: temperature, R, U, I, Relay output, 24…230 V AC/DC power supply
GTIN (EAN): 4050118505979
Qty.: 1 pc(s).
Width: 22.5 mm
Width (inches): 0.886 inch
Height: 127.1 mm
Height (inches): 5.004 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 208 g
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: Thermocouples: B, E, J, K, L, N, R, S, T, U, RTD: PT100, PT200, PT1000, Ni120, Cu10, 2-/3-/4-wire
Sensor supply: 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable
Influence of the sensor cable resistance: 5 Ω @ RTD- Kabel
Input voltage: configurable, ±150 mV DC, ± 600mV DC, ±30 V DC, ±300 V DC
Input resistance, voltage: 2 MΩ, > 10 MΩ
Input current: configurable, ± 25 mA DC, ±5 A DC
Input resistance, current: 40 Ω
Cable-length compensation: < ±0.002 Ω per cable resistance Ω
Temperature input range: B: +100…+1820 °C, E: -270…+1000 °C, J: (-210…+1200 °C), K: -270…+1372 °C, L: +100…+900 °C, N: (-180…+1300 °C), R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C
Resistance: 0…10 kΩ, 0…12 kΩ, 0…15 kΩ
Potentiometer: 1.2…500 kΩ
Configuration: With FDT/DTM software, or via 7-segment display, push-buttons and rotary encoder on the device itself
Rail: TS 35
Voltage supply: 90…264 V AC
Alarm function: configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s, Hysteresis adjustable, auto / manual reset
Number of digital outputs: 2
Type: 2 CO contacts, normal / inverse adjustment, Switching frequency 20 Hz
Max. switching voltage, DC: 110 V
Max. switching voltage, AC: 240 V
Rated switching current: 200mA @ 110Vdc, 6A @ 24Vdc / 240Vac
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002654
ETIM 7.0: EC002654
eClass 9.0: 27-21-01-22
eClass 9.1: 27-21-01-22
eClass 10.0: 27-21-01-22
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.236 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m