2495690000
ACT20P-UI-2RCO-AC-P
| Type: | ACT20P-UI-2RCO-AC-P |
| Order No.: | 2495690000 |
| Version: | Limit value monitoring, universal, Input: temperature, R, U, I, Relay output, 24…230 V AC/DC power supply |
| GTIN (EAN): | 4050118505979 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.1 mm |
| Height (inches): | 5.004 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Net weight: | 208 g |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Sensor: | Thermocouples: B, E, J, K, L, N, R, S, T, U, RTD: PT100, PT200, PT1000, Ni120, Cu10, 2-/3-/4-wire |
| Sensor supply: | 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable |
| Influence of the sensor cable resistance: | 5 Ω @ RTD- Kabel |
| Input voltage: | configurable, ±150 mV DC, ± 600mV DC, ±30 V DC, ±300 V DC |
| Input resistance, voltage: | 2 MΩ, > 10 MΩ |
| Input current: | configurable, ± 25 mA DC, ±5 A DC |
| Input resistance, current: | 40 Ω |
| Cable-length compensation: | < ±0.002 Ω per cable resistance Ω |
| Temperature input range: | B: +100…+1820 °C, E: -270…+1000 °C, J: (-210…+1200 °C), K: -270…+1372 °C, L: +100…+900 °C, N: (-180…+1300 °C), R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C |
| Resistance: | 0…10 kΩ, 0…12 kΩ, 0…15 kΩ |
| Potentiometer: | 1.2…500 kΩ |
| Configuration: | With FDT/DTM software, or via 7-segment display, push-buttons and rotary encoder on the device itself |
| Rail: | TS 35 |
| Voltage supply: | 90…264 V AC |
| Alarm function: | configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s, Hysteresis adjustable, auto / manual reset |
| Number of digital outputs: | 2 |
| Type: | 2 CO contacts, normal / inverse adjustment, Switching frequency 20 Hz |
| Max. switching voltage, DC: | 110 V |
| Max. switching voltage, AC: | 240 V |
| Rated switching current: | 200mA @ 110Vdc, 6A @ 24Vdc / 240Vac |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002654 |
| ETIM 7.0: | EC002654 |
| eClass 9.0: | 27-21-01-22 |
| eClass 9.1: | 27-21-01-22 |
| eClass 10.0: | 27-21-01-22 |
| ROHS: | Conform |
| Type: | ACT20P-UI-2RCO-AC-P |
| Order No.: | 2495690000 |
| Version: | Limit value monitoring, universal, Input: temperature, R, U, I, Relay output, 24…230 V AC/DC power supply |
| GTIN (EAN): | 4050118505979 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.1 mm |
| Height (inches): | 5.004 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Net weight: | 208 g |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Sensor: | Thermocouples: B, E, J, K, L, N, R, S, T, U, RTD: PT100, PT200, PT1000, Ni120, Cu10, 2-/3-/4-wire |
| Sensor supply: | 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable |
| Influence of the sensor cable resistance: | 5 Ω @ RTD- Kabel |
| Input voltage: | configurable, ±150 mV DC, ± 600mV DC, ±30 V DC, ±300 V DC |
| Input resistance, voltage: | 2 MΩ, > 10 MΩ |
| Input current: | configurable, ± 25 mA DC, ±5 A DC |
| Input resistance, current: | 40 Ω |
| Cable-length compensation: | < ±0.002 Ω per cable resistance Ω |
| Temperature input range: | B: +100…+1820 °C, E: -270…+1000 °C, J: (-210…+1200 °C), K: -270…+1372 °C, L: +100…+900 °C, N: (-180…+1300 °C), R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C |
| Resistance: | 0…10 kΩ, 0…12 kΩ, 0…15 kΩ |
| Potentiometer: | 1.2…500 kΩ |
| Configuration: | With FDT/DTM software, or via 7-segment display, push-buttons and rotary encoder on the device itself |
| Rail: | TS 35 |
| Voltage supply: | 90…264 V AC |
| Alarm function: | configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s, Hysteresis adjustable, auto / manual reset |
| Number of digital outputs: | 2 |
| Type: | 2 CO contacts, normal / inverse adjustment, Switching frequency 20 Hz |
| Max. switching voltage, DC: | 110 V |
| Max. switching voltage, AC: | 240 V |
| Rated switching current: | 200mA @ 110Vdc, 6A @ 24Vdc / 240Vac |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002654 |
| ETIM 7.0: | EC002654 |
| eClass 9.0: | 27-21-01-22 |
| eClass 9.1: | 27-21-01-22 |
| eClass 10.0: | 27-21-01-22 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,236 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |