Type: VPU II 1 LCF 280V/40KA
Order No.: 1352740000
Version: Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase
GTIN (EAN): 4050118157635
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 163 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 1TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 280 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 40 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.8 kV
Leakage current at Un: 1 µA
Temporary surge voltage (over-voltage) - TOV: 438 V
Combined pulse UOC: 10 kV
Number of poles: 1
Requirements category acc. to IEC 61643-11: Type II, Type III
Requirements class, acc. to EN 61643-11: T2, T3
Response time: ≤ 100 ns
Signalling contact: No
Wire connection method: Screw connection
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Single-pole surge voltage arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection in applications acc. to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor in combination with sparkover gaps satisfies the inspection requirements for Class II surge protection systems on the basis of the standards. The leakage current-free arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. The VPU II 1 LCF 280 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protect
Short specification: Class II arrester with In/Imax: 20/40 kA suitable for 230/400 V mains systems. Protection level < 1.8 kV.  Type: Weidmüller VPU II 1 LCF 280 V/12.5 kA Order no. 1352740000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VPU II 1 LCF 280V/40KA
Order No.: 1352740000
Version: Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase
GTIN (EAN): 4050118157635
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 163 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 1TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 280 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 40 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.8 kV
Leakage current at Un: 1 µA
Temporary surge voltage (over-voltage) - TOV: 438 V
Combined pulse UOC: 10 kV
Number of poles: 1
Requirements category acc. to IEC 61643-11: Type II, Type III
Requirements class, acc. to EN 61643-11: T2, T3
Response time: ≤ 100 ns
Signalling contact: No
Wire connection method: Screw connection
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Single-pole surge voltage arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection in applications acc. to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor in combination with sparkover gaps satisfies the inspection requirements for Class II surge protection systems on the basis of the standards. The leakage current-free arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. The VPU II 1 LCF 280 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protect
Short specification: Class II arrester with In/Imax: 20/40 kA suitable for 230/400 V mains systems. Protection level < 1.8 kV.  Type: Weidmüller VPU II 1 LCF 280 V/12.5 kA Order no. 1352740000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.163 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m