1352740000
VPU II 1 LCF 280V/40KA
| Type: | VPU II 1 LCF 280V/40KA |
| Order No.: | 1352740000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase |
| GTIN (EAN): | 4050118157635 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 163 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 1TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 230 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 280 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 40 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 1 µA |
| Temporary surge voltage (over-voltage) - TOV: | 438 V |
| Combined pulse UOC: | 10 kV |
| Number of poles: | 1 |
| Requirements category acc. to IEC 61643-11: | Type II, Type III |
| Requirements class, acc. to EN 61643-11: | T2, T3 |
| Response time: | ≤ 100 ns |
| Signalling contact: | No |
| Wire connection method: | Screw connection |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Single-pole surge voltage arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection in applications acc. to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor in combination with sparkover gaps satisfies the inspection requirements for Class II surge protection systems on the basis of the standards. The leakage current-free arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. The VPU II 1 LCF 280 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protect |
| Short specification: | Class II arrester with In/Imax: 20/40 kA suitable for 230/400 V mains systems. Protection level < 1.8 kV. Type: Weidmüller VPU II 1 LCF 280 V/12.5 kA Order no. 1352740000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VPU II 1 LCF 280V/40KA |
| Order No.: | 1352740000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase |
| GTIN (EAN): | 4050118157635 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 163 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black, orange |
| Design: | Installation housing; 1TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 230 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 280 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 20 kA |
| Discharge current Imax (8/20µs) wire-PE: | 40 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 1 µA |
| Temporary surge voltage (over-voltage) - TOV: | 438 V |
| Combined pulse UOC: | 10 kV |
| Number of poles: | 1 |
| Requirements category acc. to IEC 61643-11: | Type II, Type III |
| Requirements class, acc. to EN 61643-11: | T2, T3 |
| Response time: | ≤ 100 ns |
| Signalling contact: | No |
| Wire connection method: | Screw connection |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 1.5 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 1.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 1.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 1.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 1.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Single-pole surge voltage arrestor according to the requirements of Class II/III acc. to IEC 61643-11, EN61643-11:2013. Consisting of V0 material, the arrestor serves as surge protection in applications acc. to IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a high-performance varistor in combination with sparkover gaps satisfies the inspection requirements for Class II surge protection systems on the basis of the standards. The leakage current-free arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. The VPU II 1 LCF 280 V/40 kA is earthed, in combination with three or four identical arrestors, between the outer conductors (L1, L2, L3 and / or the neutral conductor). Reference is also made here to the 3+1 circuit and the 3+0 / 4+0 circuits. With thermal separation device on the varistor. If protect |
| Short specification: | Class II arrester with In/Imax: 20/40 kA suitable for 230/400 V mains systems. Protection level < 1.8 kV. Type: Weidmüller VPU II 1 LCF 280 V/12.5 kA Order no. 1352740000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,163 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |