Article image 1334890000

Weidmueller 1334890000

UR20-FBC-CAN

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: UR20-FBC-CAN
Order No.: 1334890000
Version: Remote I/O fieldbus coupler, IP20, CANopen
GTIN (EAN): 4050118138313
Qty.: 1 pc(s).
Width: 52
Width (inches): 2.047 inch
Height: 120 mm
Height (inches): 4.724 inch
Depth: 76 mm
Depth (inches): 2.992 inch
Mounting dimension - height: 128 mm
Weight: 227 g
Net weight: 220 g
Operating temperature, max.: 60 °C
Operating temperature, min.: -20 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -20 °C ... +60 °C
Storage temperature: -40 °C ... +85 °C
REACH SVHC: Lead 7439-92-1
Type of connection: PUSH IN
Wire connection cross section, finely stranded, max.: 1.5 mm²
Wire connection cross-section, finely stranded, min.: 0.14 mm²
Wire cross-section, finely stranded, max. (AWG): AWG 16
Wire cross-section, finely stranded, min. (AWG): AWG 26
Wire cross-section, solid, max.: 1.5 mm²
Wire cross-section, solid, max. (AWG): AWG 16
Wire cross-section, solid, min.: 0.14 mm²
Wire cross-section, solid, min. (AWG): AWG 26
Air humidity (operation): 10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (storage): 10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport): 10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation): ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity: 2
Shock: 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage category: II
Test voltage: 500 V
UL 94 flammability rating: V-0
Vibration resistance: 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Current consumption from IIN (power segment of the field bus coupler), typ.: 90 mA
Feed current for IIN (input current path) , max.: 10 A
Feed current for IOUT (output current path) , max.: 10 A
Feed current for the system, max.: 4 A
Supply voltage for outputs: 24 V DC +20 %/ -15 %
Supply voltage system and inputs: 24 V DC +20 %/ -15 %
Voltage supply: 24 V DC +20 %/ -15 %, via the system bus
Configuration interface: Micro USB 2.0
Connection type: 9-pole SUB-D connector (male)
Diagnostic data: 244 Byte
Field bus protocol: CANopen
Interface: u-remote system bus
Module type: Bus coupler
Parameter data: 244 Byte
Process data: 488 Byte
Transmission speed of system bus, max.: 48 Mbit/s
max. number of modules: 64 ???U150???
ETIM 6.0: EC001603
ETIM 7.0: EC001603
eClass 9.0: 27-24-26-07
eClass 9.1: 27-24-26-07
eClass 10.0: 27-24-26-07
ROHS: Conform
Type: UR20-FBC-CAN
Order No.: 1334890000
Version: Remote I/O fieldbus coupler, IP20, CANopen
GTIN (EAN): 4050118138313
Qty.: 1 pc(s).
Width: 52
Width (inches): 2.047 inch
Height: 120 mm
Height (inches): 4.724 inch
Depth: 76 mm
Depth (inches): 2.992 inch
Mounting dimension - height: 128 mm
Weight: 227 g
Net weight: 220 g
Operating temperature, max.: 60 °C
Operating temperature, min.: -20 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -20 °C ... +60 °C
Storage temperature: -40 °C ... +85 °C
REACH SVHC: Lead 7439-92-1
Type of connection: PUSH IN
Wire connection cross section, finely stranded, max.: 1.5 mm²
Wire connection cross-section, finely stranded, min.: 0.14 mm²
Wire cross-section, finely stranded, max. (AWG): AWG 16
Wire cross-section, finely stranded, min. (AWG): AWG 26
Wire cross-section, solid, max.: 1.5 mm²
Wire cross-section, solid, max. (AWG): AWG 16
Wire cross-section, solid, min.: 0.14 mm²
Wire cross-section, solid, min. (AWG): AWG 26
Air humidity (operation): 10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (storage): 10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport): 10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation): ≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport): 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity: 2
Shock: 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage category: II
Test voltage: 500 V
UL 94 flammability rating: V-0
Vibration resistance: 5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Current consumption from IIN (power segment of the field bus coupler), typ.: 90 mA
Feed current for IIN (input current path) , max.: 10 A
Feed current for IOUT (output current path) , max.: 10 A
Feed current for the system, max.: 4 A
Supply voltage for outputs: 24 V DC +20 %/ -15 %
Supply voltage system and inputs: 24 V DC +20 %/ -15 %
Voltage supply: 24 V DC +20 %/ -15 %, via the system bus
Configuration interface: Micro USB 2.0
Connection type: 9-pole SUB-D connector (male)
Diagnostic data: 244 Byte
Field bus protocol: CANopen
Interface: u-remote system bus
Module type: Bus coupler
Parameter data: 244 Byte
Process data: 488 Byte
Transmission speed of system bus, max.: 48 Mbit/s
max. number of modules: 64 ???U150???
ETIM 6.0: EC001603
ETIM 7.0: EC001603
eClass 9.0: 27-24-26-07
eClass 9.1: 27-24-26-07
eClass 10.0: 27-24-26-07
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.316 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m