3049013
RT 3
| Note: | Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories). |
| Number of levels: | 1 |
| Number of connections: | 2 |
| Potentials: | 1 |
| Nominal cross section: | 2.5 mm² |
| Color: | gray |
| Insulating material: | PA |
| Flammability rating according to UL 94: | V0 |
| Area of application: | Railway industry |
| Rated surge voltage: | 8 kV |
| Degree of pollution: | 3 |
| Overvoltage category: | III |
| Insulating material group: | I |
| Maximum power dissipation for nominal condition: | 0.77 W |
| Maximum load current: | 24 A (with a 2.5 mm² conductor cross section) |
| Nominal current IN: | 24 A |
| Nominal voltage UN: | 1000 V (Rated voltage for open disconnect point 500 V) |
| Open side panel: | Yes |
| Ambient temperature (operation): | -60 °C ... 85 °C |
| Ambient temperature (storage/transport): | -25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C) |
| Permissible humidity (storage/transport): | 30 % ... 70 % |
| Ambient temperature (assembly): | -5 °C ... 70 °C |
| Ambient temperature (actuation): | -5 °C ... 70 °C |
| Shock protection test specification: | DIN EN 50274 (VDE 0660-514):2002-11 |
| Back of the hand protection: | guaranteed |
| Finger protection: | guaranteed |
| Note regarding shock protection: | Electric shock protection only with insulated cable lug and closed wing flap guaranteed. |
| Result of surge voltage test: | Test passed |
| Result of power-frequency withstand voltage test: | Test passed |
| Power frequency withstand voltage setpoint: | 2.2 kV |
| Result of the test for mechanical stability of terminal points (5 x conductor connection): | Test passed |
| Result of tight fit on support: | Test passed |
| Tight fit on carrier: | NS 35 |
| Setpoint: | 1 N |
| Result of voltage-drop test: | Test passed |
| Result of temperature-rise test: | Test passed |
| Requirement temperature-rise test: | Increase in temperature ≤ 45 K |
| Short circuit stability result: | Test passed |
| Conductor cross section short circuit testing: | 2.5 mm² |
| Short-time current: | 0.3 kA |
| Result of thermal test: | Test passed |
| Proof of thermal characteristics (needle flame) effective duration: | 30 s |
| Oscillation, broadband noise test result: | Test passed |
| Test specification, oscillation, broadband noise: | DIN EN 50155 (VDE 0115-200):2008-03 |
| Test spectrum: | Service life test category 1, class B, body mounted |
| Test frequency: | f1 = 5 Hz to f2 = 150 Hz |
| ASD level: | 1.857 (m/s2)2/Hz |
| Acceleration: | 0,8 g |
| Test duration per axis: | 5 h |
| Test directions: | X-, Y- and Z-axis |
| Shock test result: | Test passed |
| Test specification, shock test: | DIN EN 50155 (VDE 0115-200):2008-03 |
| Shock form: | Half-sine |
| Acceleration: | 5g |
| Shock duration: | 30 ms |
| Number of shocks per direction: | 3 |
| Test directions: | X-, Y- and Z-axis (pos. and neg.) |
| Relative insulation material temperature index (Elec., UL 746 B): | 130 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): | 130 °C |
| Static insulating material application in cold: | -60 °C |
| Surface flammability NFPA 130 (ASTM E 162): | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662): | passed |
| Calorimetric heat release NFPA 130 (ASTM E 1354): | 28 MJ/kg |
| Smoke gas toxicity NFPA 130 (SMP 800C): | passed |
| Fire protection for rail vehicles (DIN EN 45545-2) R22: | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23: | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24: | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26: | HL 1 - HL 3 |
| Width: | 12.3 mm |
| End cover width: | 2.2 mm |
| Length: | 66 mm |
| Height NS 35/7,5: | 51 mm |
| Height NS 35/15: | 58.5 mm |
| Connection: | 1 level |
| Connection method: | Bolt connection |
| Stripping length: | The stripping length depends on the specification provided by the cable lug manufacturer. |
| Connection in acc. with standard: | IEC 60947-7-1 |
| Cable lug connection according to standard: | DIN 46234:1980-03 |
| Min. cross section for cable lug connection: | 0.5 mm² |
| Max. cross section for cable lug connection: | 2.5 mm² |
| AWG min: | 20 |
| AWG max: | 14 |
| Hole diameter, min.: | 3.2 mm |
| Cable lug width, max.: | 6 mm |
| Bolt diameter: | 3 mm |
| Screw thread: | M3 |
| Tightening torque, min: | 0.6 Nm |
| Tightening torque max: | 0.8 Nm |
| Cable lug connection according to standard: | DIN 46237:1970-07 |
| Min. cross section for cable lug connection: | 1 mm² |
| Max. cross section for cable lug connection: | 2.5 mm² |
| AWG min: | 18 |
| AWG max: | 14 |
| Hole diameter, min.: | 3.2 mm |
| Cable lug width, max.: | 6 mm |
| Bolt diameter: | 3 mm |
| Screw thread: | M3 |
| Tightening torque, min: | 0.6 Nm |
| Tightening torque max: | 0.8 Nm |
| Connection in acc. with standard: | CUL |
| Flammability rating according to UL 94: | V0 |
| REACh SVHC: | Lead 7439-92-1 |
| China RoHS: | Environmentally friendly use period: unlimited = EFUP-e |
| eCl@ss 10.0.1: | 27141120 |
| eCl@ss 4.0: | 27141100 |
| eCl@ss 4.1: | 27141100 |
| eCl@ss 5.0: | 27141100 |
| eCl@ss 5.1: | 27141100 |
| eCl@ss 6.0: | 27141100 |
| eCl@ss 7.0: | 27141120 |
| eCl@ss 8.0: | 27141120 |
| eCl@ss 9.0: | 27141120 |
| ETIM 2.0: | EC000897 |
| ETIM 3.0: | EC000897 |
| ETIM 4.0: | EC000897 |
| ETIM 5.0: | EC000897 |
| ETIM 6.0: | EC000897 |
| ETIM 7.0: | EC000897 |
| UNSPSC 6.01: | 30211811 |
| UNSPSC 7.0901: | 39121410 |
| UNSPSC 11: | 39121410 |
| UNSPSC 12.01: | 39121410 |
| UNSPSC 13.2: | 39121410 |
| UNSPSC 18.0: | 39121410 |
| UNSPSC 19.0: | 39121410 |
| UNSPSC 20.0: | 39121410 |
| UNSPSC 21.0: | 39121410 |
| ECCN: | |
| Country of Origin: | CN |
| EAN: | |
| Weight: | 0.024 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |