Phoenix Contact 3049013

RT 3

По запросу. Пожалуйста, отправьте нам письмо, чтобы узнать цену и наличие.
"ucnguBrctvdgcxgt0eqo"

Описание

Технические характеристики

Note: Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories).
Number of levels: 1
Number of connections: 2
Potentials: 1
Nominal cross section: 2.5 mm²
Color: gray
Insulating material: PA
Flammability rating according to UL 94: V0
Area of application: Railway industry
Rated surge voltage: 8 kV
Degree of pollution: 3
Overvoltage category: III
Insulating material group: I
Maximum power dissipation for nominal condition: 0.77 W
Maximum load current: 24 A (with a 2.5 mm² conductor cross section)
Nominal current IN: 24 A
Nominal voltage UN: 1000 V (Rated voltage for open disconnect point 500 V)
Open side panel: Yes
Ambient temperature (operation): -60 °C ... 85 °C
Ambient temperature (storage/transport): -25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C)
Permissible humidity (storage/transport): 30 % ... 70 %
Ambient temperature (assembly): -5 °C ... 70 °C
Ambient temperature (actuation): -5 °C ... 70 °C
Shock protection test specification: DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection: guaranteed
Finger protection: guaranteed
Note regarding shock protection: Electric shock protection only with insulated cable lug and closed wing flap guaranteed.
Result of surge voltage test: Test passed
Result of power-frequency withstand voltage test: Test passed
Power frequency withstand voltage setpoint: 2.2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection): Test passed
Result of tight fit on support: Test passed
Tight fit on carrier: NS 35
Setpoint: 1 N
Result of voltage-drop test: Test passed
Result of temperature-rise test: Test passed
Requirement temperature-rise test: Increase in temperature ≤ 45 K
Short circuit stability result: Test passed
Conductor cross section short circuit testing: 2.5 mm²
Short-time current: 0.3 kA
Result of thermal test: Test passed
Proof of thermal characteristics (needle flame) effective duration: 30 s
Oscillation, broadband noise test result: Test passed
Test specification, oscillation, broadband noise: DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum: Service life test category 1, class B, body mounted
Test frequency: f1 = 5 Hz to f2 = 150 Hz
ASD level: 1.857 (m/s2)2/Hz
Acceleration: 0,8 g
Test duration per axis: 5 h
Test directions: X-, Y- and Z-axis
Shock test result: Test passed
Test specification, shock test: DIN EN 50155 (VDE 0115-200):2008-03
Shock form: Half-sine
Acceleration: 5g
Shock duration: 30 ms
Number of shocks per direction: 3
Test directions: X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B): 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130 °C
Static insulating material application in cold: -60 °C
Surface flammability NFPA 130 (ASTM E 162): passed
Specific optical density of smoke NFPA 130 (ASTM E 662): passed
Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C): passed
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
Width: 12.3 mm
End cover width: 2.2 mm
Length: 66 mm
Height NS 35/7,5: 51 mm
Height NS 35/15: 58.5 mm
Connection: 1 level
Connection method: Bolt connection
Stripping length: The stripping length depends on the specification provided by the cable lug manufacturer.
Connection in acc. with standard: IEC 60947-7-1
Cable lug connection according to standard: DIN 46234:1980-03
Min. cross section for cable lug connection: 0.5 mm²
Max. cross section for cable lug connection: 2.5 mm²
AWG min: 20
AWG max: 14
Hole diameter, min.: 3.2 mm
Cable lug width, max.: 6 mm
Bolt diameter: 3 mm
Screw thread: M3
Tightening torque, min: 0.6 Nm
Tightening torque max: 0.8 Nm
Cable lug connection according to standard: DIN 46237:1970-07
Min. cross section for cable lug connection: 1 mm²
Max. cross section for cable lug connection: 2.5 mm²
AWG min: 18
AWG max: 14
Hole diameter, min.: 3.2 mm
Cable lug width, max.: 6 mm
Bolt diameter: 3 mm
Screw thread: M3
Tightening torque, min: 0.6 Nm
Tightening torque max: 0.8 Nm
Connection in acc. with standard: CUL
Flammability rating according to UL 94: V0
REACh SVHC: Lead 7439-92-1
China RoHS: Environmentally friendly use period: unlimited = EFUP-e
eCl@ss 10.0.1: 27141120
eCl@ss 4.0: 27141100
eCl@ss 4.1: 27141100
eCl@ss 5.0: 27141100
eCl@ss 5.1: 27141100
eCl@ss 6.0: 27141100
eCl@ss 7.0: 27141120
eCl@ss 8.0: 27141120
eCl@ss 9.0: 27141120
ETIM 2.0: EC000897
ETIM 3.0: EC000897
ETIM 4.0: EC000897
ETIM 5.0: EC000897
ETIM 6.0: EC000897
ETIM 7.0: EC000897
UNSPSC 6.01: 30211811
UNSPSC 7.0901: 39121410
UNSPSC 11: 39121410
UNSPSC 12.01: 39121410
UNSPSC 13.2: 39121410
UNSPSC 18.0: 39121410
UNSPSC 19.0: 39121410
UNSPSC 20.0: 39121410
UNSPSC 21.0: 39121410

Логистические характеристики

ТН ВЭД:
Страна происхождения: CN
EAN:
Вес: 0,024 kg
Длина: 0,00 m
Ширина: 0,00 m
Высота: 0,00 m