241266
VDM100-150-P/G2
Distance sensor
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, PROFIBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa. Series VDM 100 laser distance measurement devices are designed for high distances. They have a repeat accuracy of 0.5 mm. SSI and fieldbusses are used as value interfaces. These devices are used for precise positioning of rack operating units, gantry cranes, railbound vehicles, elevators and other linear movable units.
| Measurement range: | 0.3 ... 150 m |
| Reference target: | Foil reflector 500 mm x 500 mm |
| Light source: | laser diode |
| Laser nominal ratings: Note: | VISIBLE AND INVISIBLE LASER RADIATION , DO NOT STARE INTO BEAM |
| Laser nominal ratings: Laser class: | Measurement laser: 1 Alignment laser: 2 |
| Laser nominal ratings: Wave length: | Measurement laser: 905 nm Alignment laser: 660 nm |
| Laser nominal ratings: Beam divergence: | Measurement laser: 2 mrad Alignment laser: 1 mrad |
| Laser nominal ratings: Pulse length: | Measurement laser: 4 ns |
| Laser nominal ratings: Repetition rate: | Measurement laser: 20 kHz |
| Laser nominal ratings: Maximum optical power output: | Alignment laser: 0.6 mW |
| Laser nominal ratings: max. pulse energy: | Measurement laser: 12 nJ |
| Measuring method: | Pulse Ranging Technology (PRT) |
| Max. Motion velocity: | 15 m/s |
| Alignment aid: | Laser pointer |
| Life span: | > 100000 h |
| Diameter of the light spot: | < 35 cm at 150 m |
| Ambient light limit: | > 100000 Lux |
| Resolution: | 0.1 mm , adjustable |
| Temperature influence: | 0.03 mm/K |
| MTTFd: | 89 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Function indicator: | 4 LEDs |
| Control elements: | Control panel (4 membrane keys) for setting parameters |
| Parameterization indicator: | Illuminated display for displaying measured values and parameterization |
| Operating voltage: | 18 ... 30 V DC |
| No-load supply current: | 250 mA (18 V) ... 150 mA (30 V) |
| Protection class: | III (operating voltage 50 V) |
| Time delay before availability: | < 10 s |
| Interface type: | PROFIBUS DP acc. to EN 50170 |
| Transfer rate: | 9.6 kbit/s ... 12 Mbit/s , adjustable |
| Input/output type: | 2 PNP inputs/outputs, independent configuration, short-circuit protected, reverse polarity protected |
| Switching threshold: | low: Ue < 6 V, high: Ue > 16 V |
| Switching threshold: | low: Ua < 1 V, high: Ua > Ub - 1 V |
| Switching current: | 200 mA per output |
| Product standard: | EN 60947-5-2 |
| Laser safety: | IEC 60825-1:2007 |
| Measured value output: | 1 ms |
| Average data age: | 3 ms , 6 ms , 12 ms , 25 ms , 50 ms , adjustable |
| Offset: | max. 2 mm (between two devices) |
| Absolute accuracy: | ± 2.5 mm (> 3 m); ± 3.5 mm (0.3 m to 3 m) |
| Repeat accuracy: | < 0.5 mm |
| UL approval: | cULus Listed, Class 2 Power Source, Type 1 enclosure |
| FDA approval: | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 |
| Ambient temperature: | -10 ... 50 °C (14 ... 122 °F) |
| Storage temperature: | -20 ... 70 °C (-4 ... 158 °F) |
| Relative humidity: | 95 % , no moisture condensation |
| Housing width: | 140 mm |
| Housing height: | 100 mm |
| Degree of protection: | IP65 |
| Connection: | 4-pin, M12x1 connector, standard (supply) , 5-pin, M12x1 connector, B-coded (Bus In) , 5-pin, M12x1 socket, B-coded (Bus Out) , 8-pin, M12x1 connector, service |
| Material: Housing: | ABS / PC |
| Material: Optical face: | PMMA , hard coated |
| Mass: | approx. 700 g |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |