Pepperl+Fuchs 211734

WHA-UT-F7B1-0-PP-Z1-Ex2

WirelessHART

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The device is designed to connect RTDs or thermocouples from the hazardous area and provide the according temperature values into a WirelessHART network. It has an internal cold junction compensation for thermocouples. A fault is indicated by a red flashing LED per NAMUR NE44. The unit is easily configurable with a configuration tool (DTM). For additional information, refer to the manual and www.pepperl-fuchs.com.

Technical parameters

Rated voltage: 3.6 V DC , battery operated
Power dissipation/power consumption: < 0.09 W
Connection: terminals 1, 2, 3, 4
RTD: type Pt100, Pt1000 (IEC 751: 1995; GOST: alpha = 0.391)
: Connection: 2-wire: 2 sensors, 3- or 4-wire: 1 sensor
: Lead resistance: max. 10 Ω
: Measurement loop monitoring: sensor breakage
Thermocouples: type E, J, K, T (IEC 584-1)
: Cold junction compensation: internal , external
: Measurement loop monitoring: sensor breakage
: Measurement range: type K: -270 ... 1370 °C type T: -270 ... 400 °C type E: -270 ... 1000 °C type J: -210 ... 1200 °C
Resistor: Measurement range: 0 ... 500 Ω , 0 ... 4000 Ω
Voltage: mV Input
Resistor: Measurement range: -100 ... 100 mV , 0 ... 300 mV
Input resistance: ≥ 1 MΩ
Interface: internal antenna
Output variables: PV: input 1 (°C, Ω, mV) SV: input 2 (°C, Ω, mV) TV: CJC temperature (°C) estimated battery life (days) battery voltage (volts) residual battery capacity (%)
Communication: WirelessHART specifications - physical layer: IEEE 802.15.4.2006 - frequency band: 2.4 GHz (ISM band, licence free) - transmission rate: 250 kBit/s - maximum transmit power: +10 dBm (EIRP) - transmission range: outdoor 250 m, indoor 50 m (under reference conditions) - communication standard: WirelessHART
Temperature measuring range: sensor type: - TC type E: -200 ... 1000 °C, accuracy ± 0,5 °C - TC type J: -200 ... 750 °C, accuracy ± 1 °C - TC type T: -200 ... 400 °C, accuracy ± 1 °C - TC type K: -140 ... 1300 °C, accuracy ± 1 °C - RTD type Pt100: -200 ... 850 °C, accuracy ± 0,5 °C - 100 mV, accuracy ± 20 µV - 300 mV, accuracy ± 40 µV
Accuracy: - internal cold junction compensation error ± 1,5 °C (typ. acc. to IEC 61298-3) - external cold junction compensation error ± 1 °C (typ.) - resolution error < 0.1 °C - accuracy TC ± 20 µV - accuracy RTD: ± 100 mΩ
Display elements: LED PWR (battery status), one green LED LED COM (communication status), one yellow LED LED FLT (fault signal), one red LED
Control elements: 2 push buttons: - power On/Off - Join Trigger - Device Status Trigger - 2-wire RTD Wire Compensation - battery replacement confirmation
Configuration: wired interface: - HART 7.1, FSK compatible - transmission rate: 1200 Bit/s - used for device commissioning with an handheld terminal or a configuration tool (DTM)
Parameter assignment: - sampling period: 1, 2, 5, 10, 30 seconds or 1, 2, 5, 10, 30, 60 minutes - transmit power: configurable 0 dBm or 10 dBm (EIRP) - sensor type - mapping of input measuring values 1 and 2 into primary variable (PV) and secondary variable (SV) - publishing of up to three messages from the device, transmission rate selectable from 4 seconds to 60 minutes
Electromagnetic compatibility: Directive 2004/108/EC: EN 61326-1:2006
Radio and telecommunication terminal equipment: The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Electromagnetic compatibility: Directive 99/5/EC: ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
Electromagnetic compatibility: FCC CFR47 Part 15 B and C: ANSI C63.4-2003 , FCC ID: SJC-M2140
Degree of protection: IEC 60529
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Accuracy: IEC 61298-3
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -20 ... 70 °C (-4 ... 158 °F)
Relative humidity: 5 ... 95 %, noncondensing
Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60
Degree of protection: IP65
Mass: approx. 1000 g
Dimensions: 77 x 129 x 177 mm (3 x 5.08 x 6.97 inch)
Mounting: panel or pole mounting
EU-type examination certificate: IMQ 09 ATEX 008X
Electromagnetic compatibility: Marking: II 2(1)G Ex ia [ia] IIC T4
Directive conformity: Directive 94/9/EC: EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007
FM approval: CoC 3042534
IECEx approval: IECEx INE 09.0025X
Directive conformity: Approved for: Ex ia IIC T4
Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Designation: battery W-BAT-B1-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F7MK External cold junction compensation W-ACC-CJC

Logistic parameters

ECCN:
Country of Origin: Deutschland
EAN: 4050143061563
Weight: 0.74 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m