Pepperl+Fuchs 084406

NCN20+U4+N0

Inductive sensor

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Series: VariKont ®, Housing material: PBT, Output type: 2-wire, Installation: non-flush, Type of voltage: DC, Connection type: screw terminals, Degree of protection: IP68fa

Technical parameters

Switching function: Normally closed (NC)
Output type: NAMUR
Rated operating distance: 20 mm
Installation: non-flush
Assured operating distance: 0 ... 16.2 mm
Actual operating distance: 18 ... 22 mm
Reduction factor rAl: 0.37
Reduction factor rCu: 0.35
Reduction factor r304: 0.79
Output type: 2-wire
Installation conditions: A: 5 mm
Nominal voltage: 8.2 V (Ri approx. 1 kΩ)
Switching frequency: 0 ... 250 Hz
Hysteresis: 1 ... 15 typ. 5 %
Reverse polarity protection: reverse polarity protected
Short-circuit protection: yes
Current consumption: Measuring plate not detected: min. 3 mA
Current consumption: Measuring plate detected: ≤ 1 mA
Switching state indicator: LED, yellow
MTTFd: 3387 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
Standard conformity: NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999
Standard conformity: Electromagnetic compatibility: NE 21:2007
Standard conformity: Standards: EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
IECEx approval: Equipment protection level Ga: IECEx PTB 11.0021X
IECEx approval: Equipment protection level Gb: IECEx PTB 11.0021X
IECEx approval: Equipment protection level Da: IECEx PTB 11.0021X
ATEX approval: Equipment protection level Ga: PTB 00 ATEX 2032 X
ATEX approval: Equipment protection level Gb: PTB 00 ATEX 2032 X
ATEX approval: Equipment protection level Da: PTB 00 ATEX 2032 X
UL approval: Ordinary Location: E87056
UL approval: Hazardous Location: E501628
UL approval: Control drawing: 116-0451
CSA approval: cCSAus Listed, General Purpose
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: -25 ... 100 °C (-13 ... 212 °F)
Storage temperature: -40 ... 100 °C (-40 ... 212 °F)
Connection type: screw terminals
Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross-section: up to 2.5 mm2
UL approval: Minimum core cross-section: without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
UL approval: Maximum core cross-section: without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing material: PBT
Sensing face: PBT
Degree of protection: IP68
Note: Tightening torque: 1.8 Nm (housing)
Use in the hazardous area: see instruction manuals

Logistic parameters

ECCN:
Country of Origin: ID
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m