Article image KL9050

Beckhoff KL9050

KL9050 | Terminal bus extension, coupler terminal

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The KL9050 coupler terminal replaces the Bus Coupler on a Bus Terminal block. The KL9050 is the counterpart to the KL9020. The S(F)TP cable (shielded twisted pair) is plugged into the upper socket, providing the logical connection to the Bus Coupler. The extension is fully transparent for the Bus Coupler. All Bus Terminal system functions remain unchanged. The second RJ45 socket allows the system to be extended further. A new KL9050 can be connected to the first coupler terminal. The whole system can thereby be extended by 31 stations. The supply voltage for the field level and the internal electronics can be input separately. Both levels are thereby electrically isolated from one another. In the KL9050 a 400 mA K-bus power supply unit supplies the added Bus Terminals. The internal electronics and the field level can be supplied together from a single voltage source. Three diagnostic LEDs give information about the supply voltage for each Bus Terminal block, internal and field level. The KL9050 can be used as the last coupler terminal in the system or as a bridge between two Bus Terminal blocks. You can switch between these two functions with a selector switch. The switch must be correctly positioned for the system to operate.

Technical parameters

Number of Bus Terminals: 64
Current load: ≤ 10 A
Power LED: green
Defect LED:
Type/number of peripheral signals: Bus Coupler dependency
Distance between stations: max. 5 m between KL9050 and KL9050
Bus interface: 2 x RJ45 socket (input + output)
Power supply: 24 V DC (-15 %/+20 %)
Input current: 70 mA + (total K-bus current)/4, 200 mA max.
Starting current: 2.5 x continuous current
Current consumption K-bus: typ. 70 mA + (total K-bus current)/4, max. 200 mA
Current supply K-bus: up to 400 mA
Power contacts: 24 V DC max./10 A max.
Nominal voltage: 24 V DC (-15 %/+20 %)
Electrical isolation: 500 V (power contact/supply voltage/fieldbus)
PE contact: yes
Shield connection:
Electrical connection to DIN rail:
Special features: coupler terminal for K-bus extension (max. 64 Bus Terminals)
Weight: approx. 75 g
Operating/storage temperature: 0…+55 °C/-25…+85 °C
Relative humidity: 95 %, no condensation
Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos.: IP 20/variable
Approvals: CE, UL, Ex, GL