Article image 8953640000

Weidmueller 8953640000

VSPC 2SL 48VAC EX

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VSPC 2SL 48VAC EX
Order No.: 8953640000
Version: Surge protection for instrumentation and control, 48 V, 68 V, 250 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248745791
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 47 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 43
MTTF: 2,665 Years
PFH in 1*10-9 per hour: 8.9
SFF: 79.3 %
SIL in compliance with IEC 61508: 2
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Certificate No. (ATEX): KEMA10ATEX0148X
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 3 W
Input voltage, max. Ui: 75 V
Internal capacity, max. CI: < 4 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +85°C) li: 350 mA
Temperature class T5/100°C (-40 ° C ... +75°C) li: 250 mA
Temperature class T6/85 °C (-40 °C ... +60°C) li: 250 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input voltage, max. Ui: 75 V
Internal capacity, max. CI: 4 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal, miscellaneous
Optical function display: No
Protection degree: IP20
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: without warning function / function indicator
protected binary signals: 2
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 48 V
Rated voltage (DC): 68 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 60 V
Max. continuous voltage, Uc (DC): 75 V
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current, Iimp (10/350 µs) GND-PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire: 2.5 kA
Standards: IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): ≤ 300 V
Protection level on output side Wire-PE 1kV/µs, typically: 85 V
Protection level on output side Wire-wire 1 kV/µs, typically: 80 V
Protection level on output side Wire-wire 8/20 µs, typically: 80 V
Protection level, UP GND - PE: 450 V
Protection level, UP wire - PE: 80 V
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 75 V
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 60 ms
Rated current IN: 250 mA
Requirements category acc. to IEC 61643-21: C1, C2, C3, D1
Signal transmission properties (-3 dB): 2.7 MHz
Signalling contact: No
Surge current-carrying capacity C1: < 1 kA 8/20 μs
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: 4.7 Ω
Type of connection: Pluggable in VSPC BASE
Long specification: Surge protection plug for use in connection with the base element VSPC BASE 2SL FG for two wires with a common ground. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Suitable for intrinsically safe powered signal cables EX ia. Version: mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
Short specification: Surge protection plugs for base element VSPC BASE 2SL FG, coarse and fine common mode voltage protection for two wires with a common signal ground for intrinsically safe signal cables EX ia. Version: 48 V AC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSPC 2SL 48VAC EX
Order No.: 8953640000
Version: Surge protection for instrumentation and control, 48 V, 68 V, 250 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248745791
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 47 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 43
MTTF: 2,665 Years
PFH in 1*10-9 per hour: 8.9
SFF: 79.3 %
SIL in compliance with IEC 61508: 2
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Certificate No. (ATEX): KEMA10ATEX0148X
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 3 W
Input voltage, max. Ui: 75 V
Internal capacity, max. CI: < 4 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +85°C) li: 350 mA
Temperature class T5/100°C (-40 ° C ... +75°C) li: 250 mA
Temperature class T6/85 °C (-40 °C ... +60°C) li: 250 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input voltage, max. Ui: 75 V
Internal capacity, max. CI: 4 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal, miscellaneous
Optical function display: No
Protection degree: IP20
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: without warning function / function indicator
protected binary signals: 2
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 48 V
Rated voltage (DC): 68 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 60 V
Max. continuous voltage, Uc (DC): 75 V
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current, Iimp (10/350 µs) GND-PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire: 2.5 kA
Standards: IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): ≤ 300 V
Protection level on output side Wire-PE 1kV/µs, typically: 85 V
Protection level on output side Wire-wire 1 kV/µs, typically: 80 V
Protection level on output side Wire-wire 8/20 µs, typically: 80 V
Protection level, UP GND - PE: 450 V
Protection level, UP wire - PE: 80 V
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 75 V
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 60 ms
Rated current IN: 250 mA
Requirements category acc. to IEC 61643-21: C1, C2, C3, D1
Signal transmission properties (-3 dB): 2.7 MHz
Signalling contact: No
Surge current-carrying capacity C1: < 1 kA 8/20 μs
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: 4.7 Ω
Type of connection: Pluggable in VSPC BASE
Long specification: Surge protection plug for use in connection with the base element VSPC BASE 2SL FG for two wires with a common ground. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Suitable for intrinsically safe powered signal cables EX ia. Version: mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
Short specification: Surge protection plugs for base element VSPC BASE 2SL FG, coarse and fine common mode voltage protection for two wires with a common signal ground for intrinsically safe signal cables EX ia. Version: 48 V AC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.047 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m