8951690000
VSPC 2CL HF 12VDC R
| Type: | VSPC 2CL HF 12VDC R |
| Order No.: | 8951690000 |
| Version: | Surge protection for instrumentation and control, 12 V, 450 mA, IEC 61643-21, HART-compatible |
| GTIN (EAN): | 4032248742936 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 98 mm |
| Height (inches): | 3.858 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 48 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 45 |
| MTTF: | 2,537 Years |
| PFH in 1*10-9 per hour: | 4.7 |
| SFF: | 94.28 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 15 V |
| Internal capacity, max. CI: | 10 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | orange |
| Design: | Terminal, miscellaneous |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | with warning function / function indicator |
| protected current loops: | 2 |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 12 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 15 V |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 2 x 10 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 10 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 2.5 kA |
| Fuse: | 0.5 A |
| Standards: | IEC 61643-21, HART-compatible |
| Protection level UP (typ.): | < 800 V |
| Protection level on output side Wire-PE 1kV/µs, typically: | 450 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 25 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 25 V |
| Protection level, UP GND - PE: | 800 V |
| Protection level, UP wire - PE: | 450 V |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Protection level, UP wire - wire: | 25 V |
| Pulse-reset capacity: | ≤ 80 ms |
| Rated current IN: | 450 mA |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Signal transmission properties (-3 dB): | 104 MHz |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 5 kA 8/20 μs |
| Surge current-carrying capacity C3: | 100 A 10/1000 μs |
| Surge current-carrying capacity D1: | 2.5 kA 10/350 μs |
| Volume resistance: | 2.20 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Long specification: | Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. With integrated status display and remote monitoring option. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug. |
| Short specification: | Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use, 12 V DC and with integrated status display and remote monitoring option. |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSPC 2CL HF 12VDC R |
| Order No.: | 8951690000 |
| Version: | Surge protection for instrumentation and control, 12 V, 450 mA, IEC 61643-21, HART-compatible |
| GTIN (EAN): | 4032248742936 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 98 mm |
| Height (inches): | 3.858 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 48 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 45 |
| MTTF: | 2,537 Years |
| PFH in 1*10-9 per hour: | 4.7 |
| SFF: | 94.28 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 15 V |
| Internal capacity, max. CI: | 10 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | orange |
| Design: | Terminal, miscellaneous |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | with warning function / function indicator |
| protected current loops: | 2 |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 12 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 15 V |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 2 x 10 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 10 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 2.5 kA |
| Fuse: | 0.5 A |
| Standards: | IEC 61643-21, HART-compatible |
| Protection level UP (typ.): | < 800 V |
| Protection level on output side Wire-PE 1kV/µs, typically: | 450 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 25 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 25 V |
| Protection level, UP GND - PE: | 800 V |
| Protection level, UP wire - PE: | 450 V |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Protection level, UP wire - wire: | 25 V |
| Pulse-reset capacity: | ≤ 80 ms |
| Rated current IN: | 450 mA |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Signal transmission properties (-3 dB): | 104 MHz |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 5 kA 8/20 μs |
| Surge current-carrying capacity C3: | 100 A 10/1000 μs |
| Surge current-carrying capacity D1: | 2.5 kA 10/350 μs |
| Volume resistance: | 2.20 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Long specification: | Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. With integrated status display and remote monitoring option. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug. |
| Short specification: | Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use, 12 V DC and with integrated status display and remote monitoring option. |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.048 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |