8951660000
VSPC MOV 2CH 230V R
| Type: | VSPC MOV 2CH 230V R |
| Order No.: | 8951660000 |
| Version: | Surge protection for instrumentation and control, 230 V, 230 V, 10 A, IEC 61643-21 |
| GTIN (EAN): | 4032248742905 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 98 mm |
| Height (inches): | 3.858 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 47 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 77.2 |
| MTTF: | 1,479 Years |
| PFH in 1*10-9 per hour: | 0 |
| SFF: | 100 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 385 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | orange |
| Design: | Terminal, miscellaneous |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | with warning function / function indicator |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 230 V |
| Rated voltage (DC): | 230 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 275 V |
| Max. continuous voltage, Uc (DC): | 350 V |
| Discharge current In (8/20µs) GND-PE: | 1 kA |
| Discharge current Imax (8/20µs) GND-PE: | 1 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current In (8/20µs) wire-wire: | 1 kA |
| Discharge current Imax (8/20µs) wire-wire: | 1 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 0.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 0.2 kA |
| Fuse: | 10A |
| Standards: | IEC 61643-21 |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 600 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 700 V |
| Capacitance: | 720 pF |
| Number of poles: | 1 |
| Overload - failure mode: | Mode 1 |
| Protection level, UP wire - wire: | 850 V |
| Rated current IN: | 10 A |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 1 kA 8/20 μs |
| Surge current-carrying capacity C3: | 50 A 10/1000 μs |
| Surge current-carrying capacity D1: | 0.5 kA 10/350 μs |
| Volume resistance: | 0.20 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Product information: | External wire bridges must be used for connection to PE. |
| Long specification: | Surge protection plug for base element VSPC BASE 2/4CH, common mode voltage protection for two paired cables with integrated status display and remote monitoring option. Version: 230 V AC Single-stage protective circuitry in plug, consisting of varistor protection between the signal wires. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug. |
| Short specification: | Surge protection plug for base element VSPC BASE 2/4CH, common mode voltage protection for two paired cables with integrated status display and remote monitoring option. Version: 230 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSPC MOV 2CH 230V R |
| Order No.: | 8951660000 |
| Version: | Surge protection for instrumentation and control, 230 V, 230 V, 10 A, IEC 61643-21 |
| GTIN (EAN): | 4032248742905 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 98 mm |
| Height (inches): | 3.858 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 47 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 77.2 |
| MTTF: | 1,479 Years |
| PFH in 1*10-9 per hour: | 0 |
| SFF: | 100 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 385 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | orange |
| Design: | Terminal, miscellaneous |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | with warning function / function indicator |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 230 V |
| Rated voltage (DC): | 230 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 275 V |
| Max. continuous voltage, Uc (DC): | 350 V |
| Discharge current In (8/20µs) GND-PE: | 1 kA |
| Discharge current Imax (8/20µs) GND-PE: | 1 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current In (8/20µs) wire-wire: | 1 kA |
| Discharge current Imax (8/20µs) wire-wire: | 1 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 0.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 0.2 kA |
| Fuse: | 10A |
| Standards: | IEC 61643-21 |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 600 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 700 V |
| Capacitance: | 720 pF |
| Number of poles: | 1 |
| Overload - failure mode: | Mode 1 |
| Protection level, UP wire - wire: | 850 V |
| Rated current IN: | 10 A |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 1 kA 8/20 μs |
| Surge current-carrying capacity C3: | 50 A 10/1000 μs |
| Surge current-carrying capacity D1: | 0.5 kA 10/350 μs |
| Volume resistance: | 0.20 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Product information: | External wire bridges must be used for connection to PE. |
| Long specification: | Surge protection plug for base element VSPC BASE 2/4CH, common mode voltage protection for two paired cables with integrated status display and remote monitoring option. Version: 230 V AC Single-stage protective circuitry in plug, consisting of varistor protection between the signal wires. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug. |
| Short specification: | Surge protection plug for base element VSPC BASE 2/4CH, common mode voltage protection for two paired cables with integrated status display and remote monitoring option. Version: 230 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.047 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |