7760054165
ACT20P-VMR-3PH-ILP-H-S
| Type: | ACT20P-VMR-3PH-ILP-H-S |
| Order No.: | 7760054165 |
| Version: | Limit value monitoring, Input: 3-phase voltage, Relay output |
| GTIN (EAN): | 6944169689086 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 |
| Width (inches): | 0.886 inch |
| Height: | 117 mm |
| Height (inches): | 4.606 inch |
| Depth: | 114.3 mm |
| Depth (inches): | 4.5 inch |
| Net weight: | 233 g |
| Humidity: | 5...85 % rel. humidity, no condensation |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -25 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -25 °C...60 °C |
| Storage temperature: | -40 °C...85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (cURus): | E469563 |
| Number of inputs: | 1 |
| Type: | 3-phase, AC voltage |
| Input voltage: | 180…500 VAC |
| Input resistance, voltage: | ≥1,8MΩ |
| Input measurement range: | 200…480 VAC |
| Input frequency: | 40…60 Hz |
| Configuration: | DIP switch and potentiometer |
| Galvanic isolation: | 2-way isolator, between input/output |
| Power consumption: | ≤ 3VA |
| Rail: | TS 35 |
| Step response time: | ≤ 100 ms |
| Temperature coefficient: | 350 ppm/K |
| Unbalanced: | Hysteresis: 5%, Phase imbalance in range of adjustment: 5...25%, OFF |
| Voltage supply: | supplied from voltage measurement inputs |
| EMC standards: | EN 61326-1 |
| Galvanic isolation: | 2-way isolator, between input/output |
| Impulse withstand voltage: | 6 kV (input - output), 4 kV (output 1- output 2), 1.2/50 µs |
| Insulation voltage: | 2.5 kV (input / output) |
| Pollution severity: | 2 |
| Rated voltage: | 600 VAC (input - output), 300 VAC (output 1 - output 2) |
| Surge voltage category: | III |
| Alarm function: | Top and bottom limit values, window range, Holding function can be activated, Phase error, Phase sequence, Asymmetry, Alarm delay: 0…10 s |
| Hysteresis: | 5 % @ Phase asymmetry |
| Number of digital outputs: | 2 |
| Type: | 2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted |
| Max. switching voltage, DC: | 30 V |
| Max. switching voltage, AC: | 250 V |
| Rated switching current: | 5 A |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.6 Nm |
| Clamping range, rated connection: | 1.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 12 |
| ETIM 6.0: | EC002654 |
| ETIM 7.0: | EC002654 |
| eClass 9.0: | 27-21-01-22 |
| eClass 9.1: | 27-21-01-22 |
| eClass 10.0: | 27-21-01-22 |
| ROHS: | Conform |
| Type: | ACT20P-VMR-3PH-ILP-H-S |
| Order No.: | 7760054165 |
| Version: | Limit value monitoring, Input: 3-phase voltage, Relay output |
| GTIN (EAN): | 6944169689086 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 |
| Width (inches): | 0.886 inch |
| Height: | 117 mm |
| Height (inches): | 4.606 inch |
| Depth: | 114.3 mm |
| Depth (inches): | 4.5 inch |
| Net weight: | 233 g |
| Humidity: | 5...85 % rel. humidity, no condensation |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -25 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -25 °C...60 °C |
| Storage temperature: | -40 °C...85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (cURus): | E469563 |
| Number of inputs: | 1 |
| Type: | 3-phase, AC voltage |
| Input voltage: | 180…500 VAC |
| Input resistance, voltage: | ≥1,8MΩ |
| Input measurement range: | 200…480 VAC |
| Input frequency: | 40…60 Hz |
| Configuration: | DIP switch and potentiometer |
| Galvanic isolation: | 2-way isolator, between input/output |
| Power consumption: | ≤ 3VA |
| Rail: | TS 35 |
| Step response time: | ≤ 100 ms |
| Temperature coefficient: | 350 ppm/K |
| Unbalanced: | Hysteresis: 5%, Phase imbalance in range of adjustment: 5...25%, OFF |
| Voltage supply: | supplied from voltage measurement inputs |
| EMC standards: | EN 61326-1 |
| Galvanic isolation: | 2-way isolator, between input/output |
| Impulse withstand voltage: | 6 kV (input - output), 4 kV (output 1- output 2), 1.2/50 µs |
| Insulation voltage: | 2.5 kV (input / output) |
| Pollution severity: | 2 |
| Rated voltage: | 600 VAC (input - output), 300 VAC (output 1 - output 2) |
| Surge voltage category: | III |
| Alarm function: | Top and bottom limit values, window range, Holding function can be activated, Phase error, Phase sequence, Asymmetry, Alarm delay: 0…10 s |
| Hysteresis: | 5 % @ Phase asymmetry |
| Number of digital outputs: | 2 |
| Type: | 2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted |
| Max. switching voltage, DC: | 30 V |
| Max. switching voltage, AC: | 250 V |
| Rated switching current: | 5 A |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.6 Nm |
| Clamping range, rated connection: | 1.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 12 |
| ETIM 6.0: | EC002654 |
| ETIM 7.0: | EC002654 |
| eClass 9.0: | 27-21-01-22 |
| eClass 9.1: | 27-21-01-22 |
| eClass 10.0: | 27-21-01-22 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.233 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |