Article image 7760054165

Weidmueller 7760054165

ACT20P-VMR-3PH-ILP-H-S

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ACT20P-VMR-3PH-ILP-H-S
Order No.: 7760054165
Version: Limit value monitoring, Input: 3-phase voltage, Relay output
GTIN (EAN): 6944169689086
Qty.: 1 pc(s).
Width: 22.5
Width (inches): 0.886 inch
Height: 117 mm
Height (inches): 4.606 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 233 g
Humidity: 5...85 % rel. humidity, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E469563
Number of inputs: 1
Type: 3-phase, AC voltage
Input voltage: 180…500 VAC
Input resistance, voltage: ≥1,8MΩ
Input measurement range: 200…480 VAC
Input frequency: 40…60 Hz
Configuration: DIP switch and potentiometer
Galvanic isolation: 2-way isolator, between input/output
Power consumption: ≤ 3VA
Rail: TS 35
Step response time: ≤ 100 ms
Temperature coefficient: 350 ppm/K
Unbalanced: Hysteresis: 5%, Phase imbalance in range of adjustment: 5...25%, OFF
Voltage supply: supplied from voltage measurement inputs
EMC standards: EN 61326-1
Galvanic isolation: 2-way isolator, between input/output
Impulse withstand voltage: 6 kV (input - output), 4 kV (output 1- output 2), 1.2/50 µs
Insulation voltage: 2.5 kV (input / output)
Pollution severity: 2
Rated voltage: 600 VAC (input - output), 300 VAC (output 1 - output 2)
Surge voltage category: III
Alarm function: Top and bottom limit values, window range, Holding function can be activated, Phase error, Phase sequence, Asymmetry, Alarm delay: 0…10 s
Hysteresis: 5 % @ Phase asymmetry
Number of digital outputs: 2
Type: 2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted
Max. switching voltage, DC: 30 V
Max. switching voltage, AC: 250 V
Rated switching current: 5 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002654
ETIM 7.0: EC002654
eClass 9.0: 27-21-01-22
eClass 9.1: 27-21-01-22
eClass 10.0: 27-21-01-22
ROHS: Conform
Type: ACT20P-VMR-3PH-ILP-H-S
Order No.: 7760054165
Version: Limit value monitoring, Input: 3-phase voltage, Relay output
GTIN (EAN): 6944169689086
Qty.: 1 pc(s).
Width: 22.5
Width (inches): 0.886 inch
Height: 117 mm
Height (inches): 4.606 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 233 g
Humidity: 5...85 % rel. humidity, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E469563
Number of inputs: 1
Type: 3-phase, AC voltage
Input voltage: 180…500 VAC
Input resistance, voltage: ≥1,8MΩ
Input measurement range: 200…480 VAC
Input frequency: 40…60 Hz
Configuration: DIP switch and potentiometer
Galvanic isolation: 2-way isolator, between input/output
Power consumption: ≤ 3VA
Rail: TS 35
Step response time: ≤ 100 ms
Temperature coefficient: 350 ppm/K
Unbalanced: Hysteresis: 5%, Phase imbalance in range of adjustment: 5...25%, OFF
Voltage supply: supplied from voltage measurement inputs
EMC standards: EN 61326-1
Galvanic isolation: 2-way isolator, between input/output
Impulse withstand voltage: 6 kV (input - output), 4 kV (output 1- output 2), 1.2/50 µs
Insulation voltage: 2.5 kV (input / output)
Pollution severity: 2
Rated voltage: 600 VAC (input - output), 300 VAC (output 1 - output 2)
Surge voltage category: III
Alarm function: Top and bottom limit values, window range, Holding function can be activated, Phase error, Phase sequence, Asymmetry, Alarm delay: 0…10 s
Hysteresis: 5 % @ Phase asymmetry
Number of digital outputs: 2
Type: 2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted
Max. switching voltage, DC: 30 V
Max. switching voltage, AC: 250 V
Rated switching current: 5 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002654
ETIM 7.0: EC002654
eClass 9.0: 27-21-01-22
eClass 9.1: 27-21-01-22
eClass 10.0: 27-21-01-22
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.233 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m