Type: ACT20P-UI-AO-DO-LP-P
Order No.: 2456850000
Version: Limit value monitoring, Input: temperature, R, U, I, Output: 4 - 20 mA, Output current loop powered, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered)
GTIN (EAN): 4050118471786
Qty.: 1 pc(s).
Width: 12.5 mm
Width (inches): 0.492 inch
Height: 127.1 mm
Height (inches): 5.004 inch
Depth: 113.7 mm
Depth (inches): 4.476 inch
Net weight: 80 g
Humidity: 10…90 %, no condensation
Operating temperature, max.: 70 °C
Operating temperature, min.: -20 °C
Storage temperature, max.: 70 °C
Storage temperature, min.: -20 °C
Operating temperature: -20 °C...70 °C
Ambient temperature: -20 °C...+70 °C
Storage temperature: -20 °C...70 °C
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Type: Universal signal isolator / signal amplifier, thermocouple, RTD
Sensor: PT100 (2-/3- wire), PT1000 (2-/3- wire), PT200, N120, Cu 10, Thermocouples: B, E, J, K, L, N, R, S, T, U
Sensor supply: 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable
Influence of the sensor cable resistance: 5 Ω @ RTD- Kabel
Input voltage: configurable, -150…+150 mV DC (min. measurement range15 mV), -600…+600 mV DC (min. measurement range 50 mV), ± 12 V DC (min. measurement range 1 V), ± 28 V DC (min. measurement range 2 V), ± 300 V DC (min. measurement range 100 V), 0…1 V AC (min. measurement range300 mV), 0…250 V AC (min. measurement range 100 V)
Input resistance, voltage: > 10 MΩ @ 600 mV, 2 MΩ
Input current: configurable, ± 5 A DC (min. measurement range 0.5 A)
Input resistance, current: 40 Ω
Cable-length compensation: < ±0.002 Ω per cable resistance Ω
Temperature input range: CU10: -100…+260 °C, Ni120: -80 °C…+320 °C, PT100 / 200 / 1000: -200 °C…+850 °C, B: +100…+1820 °C, E: -270…+1000 °C, J: -270…+1200 °C, K: -270…+1372 °C, L: +100…+900 °C, N: -180…+1300 °C, R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C
Resistance: 0…750 Ω, 0…1.5 kΩ, 0…12 kΩ
Potentiometer: 1.2…500 kΩ
Accuracy: < 0.1 % of measuring range
Cold-junction compensation error: ±1.0°C @ -20° C - 65°C
Configuration: With FDT/DTM software
Galvanic isolation: 2-way isolator, between input/output
Rail: TS 35
Step response time: 450 ms
Temperature coefficient: < 0.02 °C of measuring range / °C
Voltage supply: Output loop powered, (10…45 V)
Galvanic isolation: 2-way isolator, between input/output
Impulse withstand voltage: 4 kV (1.2/50 µs)
Insulation voltage: 3.51 kV between input and output
Pollution severity: 2
Surge voltage category: III
Output current: 4...20 mA (current loop)
Signal output: direct or inverted
Alarm function: configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s
Hysteresis: ≥ 0.1 % of FS
Number of digital outputs: 1
Type: Transistor, open collector
Rated switching current: 20 mA
Rated switching voltage: ≤ 30 V DC
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform
Type: ACT20P-UI-AO-DO-LP-P
Order No.: 2456850000
Version: Limit value monitoring, Input: temperature, R, U, I, Output: 4 - 20 mA, Output current loop powered, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered)
GTIN (EAN): 4050118471786
Qty.: 1 pc(s).
Width: 12.5 mm
Width (inches): 0.492 inch
Height: 127.1 mm
Height (inches): 5.004 inch
Depth: 113.7 mm
Depth (inches): 4.476 inch
Net weight: 80 g
Humidity: 10…90 %, no condensation
Operating temperature, max.: 70 °C
Operating temperature, min.: -20 °C
Storage temperature, max.: 70 °C
Storage temperature, min.: -20 °C
Operating temperature: -20 °C...70 °C
Ambient temperature: -20 °C...+70 °C
Storage temperature: -20 °C...70 °C
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Type: Universal signal isolator / signal amplifier, thermocouple, RTD
Sensor: PT100 (2-/3- wire), PT1000 (2-/3- wire), PT200, N120, Cu 10, Thermocouples: B, E, J, K, L, N, R, S, T, U
Sensor supply: 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable
Influence of the sensor cable resistance: 5 Ω @ RTD- Kabel
Input voltage: configurable, -150…+150 mV DC (min. measurement range15 mV), -600…+600 mV DC (min. measurement range 50 mV), ± 12 V DC (min. measurement range 1 V), ± 28 V DC (min. measurement range 2 V), ± 300 V DC (min. measurement range 100 V), 0…1 V AC (min. measurement range300 mV), 0…250 V AC (min. measurement range 100 V)
Input resistance, voltage: > 10 MΩ @ 600 mV, 2 MΩ
Input current: configurable, ± 5 A DC (min. measurement range 0.5 A)
Input resistance, current: 40 Ω
Cable-length compensation: < ±0.002 Ω per cable resistance Ω
Temperature input range: CU10: -100…+260 °C, Ni120: -80 °C…+320 °C, PT100 / 200 / 1000: -200 °C…+850 °C, B: +100…+1820 °C, E: -270…+1000 °C, J: -270…+1200 °C, K: -270…+1372 °C, L: +100…+900 °C, N: -180…+1300 °C, R: -50…+1768 °C, S: -50…+1768 °C, T: -270…+400 °C, U: -200…+600 °C
Resistance: 0…750 Ω, 0…1.5 kΩ, 0…12 kΩ
Potentiometer: 1.2…500 kΩ
Accuracy: < 0.1 % of measuring range
Cold-junction compensation error: ±1.0°C @ -20° C - 65°C
Configuration: With FDT/DTM software
Galvanic isolation: 2-way isolator, between input/output
Rail: TS 35
Step response time: 450 ms
Temperature coefficient: < 0.02 °C of measuring range / °C
Voltage supply: Output loop powered, (10…45 V)
Galvanic isolation: 2-way isolator, between input/output
Impulse withstand voltage: 4 kV (1.2/50 µs)
Insulation voltage: 3.51 kV between input and output
Pollution severity: 2
Surge voltage category: III
Output current: 4...20 mA (current loop)
Signal output: direct or inverted
Alarm function: configurable, Top and bottom limit values, window range, Alarm delay: 0…99 s
Hysteresis: ≥ 0.1 % of FS
Number of digital outputs: 1
Type: Transistor, open collector
Rated switching current: 20 mA
Rated switching voltage: ≤ 30 V DC
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-90
eClass 10.0: 27-21-01-20
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN: