2456820000
ACT20P-BRIDGE-P
| Type: | ACT20P-BRIDGE-P |
| Order No.: | 2456820000 |
| Version: | Measuring bridge converter, Resistance measuring bridge, 0(4)-20 mA |
| GTIN (EAN): | 4050118471762 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.1 mm |
| Height (inches): | 5.004 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Net weight: | 157 g |
| Humidity: | 10…90 %, no condensation |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Sensor: | Resistance measuring bridge, Total resistance of all parallel resistance measuring bridges: min. 87Ω |
| Sensor supply: | 120 mA @ 10 V (= 4 x 350 Ω bridge resistors) |
| Input measurement range: | ± 10 mV / ± 20 mV / ± 30 mV / ± 50 mV (adjustable) |
| Bridge supply voltage: | 5 V or 10 V |
| Bridge sensitivity: | 1.0 mV / V to 5.0 mV / V |
| Type: | Voltage and current output (configurable) |
| Output voltage, note: | 0…11 V (adjustable) |
| Output current: | 0…22 mA (adjustable) |
| load impedance voltage: | 600 Ω |
| Load impedance current: | ≤ 600 Ω |
| Configuration: | DIP switch and button |
| Linearity: | Typically ± 0.05 % of signal range |
| Long-term drift: | 0.1 % / 10.000 h |
| Power consumption: | 3 W @ 24 V DC |
| Rail: | TS 35 |
| Repeat accuracy: | ± 0.05 % of final value |
| Step response time: | < 400 ms (10…90 %) |
| Temperature coefficient: | typ. 0.005 % / °C |
| Voltage supply: | 10…60 V DC |
| EMC standards: | EN 61326 |
| Insulation voltage: | 5.7 kV (input / output, input / supply) |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Type (analogue output): | Voltage and current output (configurable) |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| Approvals: | CULUS; |
| ROHS: | Conform |
| Type: | ACT20P-BRIDGE-P |
| Order No.: | 2456820000 |
| Version: | Measuring bridge converter, Resistance measuring bridge, 0(4)-20 mA |
| GTIN (EAN): | 4050118471762 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.1 mm |
| Height (inches): | 5.004 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Net weight: | 157 g |
| Humidity: | 10…90 %, no condensation |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Sensor: | Resistance measuring bridge, Total resistance of all parallel resistance measuring bridges: min. 87Ω |
| Sensor supply: | 120 mA @ 10 V (= 4 x 350 Ω bridge resistors) |
| Input measurement range: | ± 10 mV / ± 20 mV / ± 30 mV / ± 50 mV (adjustable) |
| Bridge supply voltage: | 5 V or 10 V |
| Bridge sensitivity: | 1.0 mV / V to 5.0 mV / V |
| Type: | Voltage and current output (configurable) |
| Output voltage, note: | 0…11 V (adjustable) |
| Output current: | 0…22 mA (adjustable) |
| load impedance voltage: | 600 Ω |
| Load impedance current: | ≤ 600 Ω |
| Configuration: | DIP switch and button |
| Linearity: | Typically ± 0.05 % of signal range |
| Long-term drift: | 0.1 % / 10.000 h |
| Power consumption: | 3 W @ 24 V DC |
| Rail: | TS 35 |
| Repeat accuracy: | ± 0.05 % of final value |
| Step response time: | < 400 ms (10…90 %) |
| Temperature coefficient: | typ. 0.005 % / °C |
| Voltage supply: | 10…60 V DC |
| EMC standards: | EN 61326 |
| Insulation voltage: | 5.7 kV (input / output, input / supply) |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Type (analogue output): | Voltage and current output (configurable) |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| Approvals: | CULUS; |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.198 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |