Type: ACT20C-CML-10-AO-RC-S
Order No.: 2044840000
Version: Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
GTIN (EAN): 4050118409826
Qty.: 1 pc(s).
Width: 17.5
Width (inches): 0.689 inch
Height: 117.2 mm
Height (inches): 4.614 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 134 g
Humidity: 5...95 %, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTTF: 130 Years
REACH SVHC: Lead 7439-92-1
Configuration: for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software
Input signal: Power cable can be connected to the terminals
Input measurement range: configurable, 0…1/5/10 A AC (RMS) or DC
Input frequency: AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Accuracy: ≤ ±0.3 % @ 1 A ⁄ 5 A, ≤ ±0.6 % @ 10 A
Configuration: for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.: 2.2 W
Rail: TS 35
Step response time: ≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient: ≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, IEC 61010-2-201
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage: 6 kV (1.2/50 µs)
Pollution severity: 2
Surge voltage category: III
Load resistance current: ≤ 600 Ω
Load resistance voltage: ≥ 10 kΩ
Output current: Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage: Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output): Voltage and current output (configurable)
Type: Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s
Max. switching voltage, DC: 24 V
Max. switching voltage, AC: 250 V
Rated switching current: 2 A
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 3.5 Lb In
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 2.5 mm²
ETIM 6.0: EC002475
ETIM 7.0: EC002475
eClass 9.0: 27-21-01-23
eClass 9.1: 27-21-01-23
eClass 10.0: 27-21-01-23
ROHS: Conform
Type: ACT20C-CML-10-AO-RC-S
Order No.: 2044840000
Version: Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
GTIN (EAN): 4050118409826
Qty.: 1 pc(s).
Width: 17.5
Width (inches): 0.689 inch
Height: 117.2 mm
Height (inches): 4.614 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 134 g
Humidity: 5...95 %, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTTF: 130 Years
REACH SVHC: Lead 7439-92-1
Configuration: for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software
Input signal: Power cable can be connected to the terminals
Input measurement range: configurable, 0…1/5/10 A AC (RMS) or DC
Input frequency: AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Accuracy: ≤ ±0.3 % @ 1 A ⁄ 5 A, ≤ ±0.6 % @ 10 A
Configuration: for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.: 2.2 W
Rail: TS 35
Step response time: ≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient: ≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, IEC 61010-2-201
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage: 6 kV (1.2/50 µs)
Pollution severity: 2
Surge voltage category: III
Load resistance current: ≤ 600 Ω
Load resistance voltage: ≥ 10 kΩ
Output current: Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage: Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output): Voltage and current output (configurable)
Type: Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s
Max. switching voltage, DC: 24 V
Max. switching voltage, AC: 250 V
Rated switching current: 2 A
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 3.5 Lb In
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 2.5 mm²
ETIM 6.0: EC002475
ETIM 7.0: EC002475
eClass 9.0: 27-21-01-23
eClass 9.1: 27-21-01-23
eClass 10.0: 27-21-01-23
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.194 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m