Article image 1510440000

Weidmueller 1510440000

ACT20P-CMT-60-AO-RC-S

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ACT20P-CMT-60-AO-RC-S
Order No.: 1510440000
Version: Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, Screw connection, Input measurement range: configurable, 0…40/50/60 A AC or DC
GTIN (EAN): 4050118319620
Qty.: 1 pc(s).
Width: 22.5 mm
Width (inches): 0.886 inch
Height: 119.2 mm
Height (inches): 4.693 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 158 g
Humidity: 5...95 %, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Storage temperature: -40 °C...85 °C
MTTF: 158 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Input signal: Current-carrying cable in feed-through hole, Diameter 10.5 mm
Input measurement range: configurable, 0…40/50/60 A AC or DC
Input frequency: AC: 15…700 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Accuracy: < 0.75 % FSR, < 1.5 % FSR with measurement range 50/60 A AC
Configuration: DIP switch and potentiometer
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.: 2.2 W
Rail: TS 35
Step response time: ≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient: 0.01%/K @ 0...40 A, 0.10%/K @ 40...55 A, 0.30%/K @ 55...60 A
Voltage supply: 16,8 V…31,2 V
EMC standards: IEC 61326-1, IEC 61010-2-201
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage: 6.4 kV (1.2/50 µs)
Pollution severity: 2
Surge voltage category: III
Load resistance current: ≤ 600 Ω
Load resistance voltage: ≥ 10 kΩ
Output current: Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage: Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output): Voltage and current output (configurable)
Alarm function: Surge current, Under-current, Alarm delay: 0…10 s, Hysteresis 5% / 10%
Number of digital outputs: 1
Type: Relay, 1 CO contact, normal / inverse adjustment
Max. switching voltage, DC: 24 V
Max. switching voltage, AC: 250 V
Rated switching current: 6 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002475
ETIM 7.0: EC002475
eClass 9.0: 27-21-01-23
eClass 9.1: 27-21-01-23
eClass 10.0: 27-21-01-23
ROHS: Conform
Type: ACT20P-CMT-60-AO-RC-S
Order No.: 1510440000
Version: Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Analogue output, Screw connection, Input measurement range: configurable, 0…40/50/60 A AC or DC
GTIN (EAN): 4050118319620
Qty.: 1 pc(s).
Width: 22.5 mm
Width (inches): 0.886 inch
Height: 119.2 mm
Height (inches): 4.693 inch
Depth: 113.6 mm
Depth (inches): 4.472 inch
Net weight: 158 g
Humidity: 5...95 %, no condensation
Operating temperature, max.: 60 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...60 °C
Storage temperature: -40 °C...85 °C
MTTF: 158 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Input signal: Current-carrying cable in feed-through hole, Diameter 10.5 mm
Input measurement range: configurable, 0…40/50/60 A AC or DC
Input frequency: AC: 15…700 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Accuracy: < 0.75 % FSR, < 1.5 % FSR with measurement range 50/60 A AC
Configuration: DIP switch and potentiometer
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.: 2.2 W
Rail: TS 35
Step response time: ≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient: 0.01%/K @ 0...40 A, 0.10%/K @ 40...55 A, 0.30%/K @ 55...60 A
Voltage supply: 16,8 V…31,2 V
EMC standards: IEC 61326-1, IEC 61010-2-201
Galvanic isolation: 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage: 6.4 kV (1.2/50 µs)
Pollution severity: 2
Surge voltage category: III
Load resistance current: ≤ 600 Ω
Load resistance voltage: ≥ 10 kΩ
Output current: Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage: Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output): Voltage and current output (configurable)
Alarm function: Surge current, Under-current, Alarm delay: 0…10 s, Hysteresis 5% / 10%
Number of digital outputs: 1
Type: Relay, 1 CO contact, normal / inverse adjustment
Max. switching voltage, DC: 24 V
Max. switching voltage, AC: 250 V
Rated switching current: 6 A
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 12
ETIM 6.0: EC002475
ETIM 7.0: EC002475
eClass 9.0: 27-21-01-23
eClass 9.1: 27-21-01-23
eClass 10.0: 27-21-01-23
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.207 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m