1510240000
ACT20C-CMT-10-AO-RC-S
| Type: | ACT20C-CMT-10-AO-RC-S |
| Order No.: | 1510240000 |
| Version: | Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay |
| GTIN (EAN): | 4050118319460 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 |
| Width (inches): | 0.886 inch |
| Height: | 117.2 mm |
| Height (inches): | 4.614 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Weight: | 180 g |
| Net weight: | 154 g |
| Humidity: | 5...95 %, no condensation |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -25 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -25 °C...60 °C |
| Ambient temperature: | -25 °C...+60 °C |
| Storage temperature: | -40 °C...85 °C |
| MTTF: | 130 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Configuration: | With FDT/DTM software, via gateway (ACT20C-GTW-100-MTCP-S), Addressing via DIP switches |
| Interface: | Communication via CH20M rail bus with gateway (ACT20C-GTW-100-MTCP-S) |
| Input signal: | Current-carrying cable in feed-through hole, Diameter 10.5 mm |
| Input measurement range: | configurable, 0…5/10 A AC (RMS) or DC |
| Input frequency: | AC: 15…700 Hz |
| Accuracy: | < 0.75 % FSR |
| Configuration: | With FDT/DTM software, via gateway (ACT20C-GTW-100-MTCP-S), Addressing via DIP switches |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Power consumption, max.: | 2.2 W |
| Rail: | TS 35 |
| Step response time: | < 300 ms |
| Temperature coefficient: | typ. 0.04 % / K, max. 0.09 % / K |
| Voltage supply: | via the system bus |
| EMC standards: | IEC 61326-1 |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Impulse withstand voltage: | 6.4 kV (1.2/50 µs) |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Load resistance current: | ≤ 600 Ω |
| Load resistance voltage: | ≥ 10 kΩ |
| Output current: | Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA |
| Output voltage: | Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V |
| Type (analogue output): | Voltage and current output (configurable) |
| Type: | Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s |
| Max. switching voltage, DC: | 24 V |
| Max. switching voltage, AC: | 250 V |
| Rated switching current: | 6 A |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 3.5 Lb In |
| Clamping range, rated connection: | 1.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 30 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| ETIM 6.0: | EC002475 |
| ETIM 7.0: | EC002475 |
| eClass 9.0: | 27-21-01-23 |
| eClass 9.1: | 27-21-01-23 |
| eClass 10.0: | 27-21-01-23 |
| ROHS: | Conform |
| Type: | ACT20C-CMT-10-AO-RC-S |
| Order No.: | 1510240000 |
| Version: | Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay |
| GTIN (EAN): | 4050118319460 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 |
| Width (inches): | 0.886 inch |
| Height: | 117.2 mm |
| Height (inches): | 4.614 inch |
| Depth: | 113.6 mm |
| Depth (inches): | 4.472 inch |
| Weight: | 180 g |
| Net weight: | 154 g |
| Humidity: | 5...95 %, no condensation |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -25 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -25 °C...60 °C |
| Ambient temperature: | -25 °C...+60 °C |
| Storage temperature: | -40 °C...85 °C |
| MTTF: | 130 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Configuration: | With FDT/DTM software, via gateway (ACT20C-GTW-100-MTCP-S), Addressing via DIP switches |
| Interface: | Communication via CH20M rail bus with gateway (ACT20C-GTW-100-MTCP-S) |
| Input signal: | Current-carrying cable in feed-through hole, Diameter 10.5 mm |
| Input measurement range: | configurable, 0…5/10 A AC (RMS) or DC |
| Input frequency: | AC: 15…700 Hz |
| Accuracy: | < 0.75 % FSR |
| Configuration: | With FDT/DTM software, via gateway (ACT20C-GTW-100-MTCP-S), Addressing via DIP switches |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Power consumption, max.: | 2.2 W |
| Rail: | TS 35 |
| Step response time: | < 300 ms |
| Temperature coefficient: | typ. 0.04 % / K, max. 0.09 % / K |
| Voltage supply: | via the system bus |
| EMC standards: | IEC 61326-1 |
| Galvanic isolation: | 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay |
| Impulse withstand voltage: | 6.4 kV (1.2/50 µs) |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Load resistance current: | ≤ 600 Ω |
| Load resistance voltage: | ≥ 10 kΩ |
| Output current: | Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA |
| Output voltage: | Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V |
| Type (analogue output): | Voltage and current output (configurable) |
| Type: | Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s |
| Max. switching voltage, DC: | 24 V |
| Max. switching voltage, AC: | 250 V |
| Rated switching current: | 6 A |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 3.5 Lb In |
| Clamping range, rated connection: | 1.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 30 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| ETIM 6.0: | EC002475 |
| ETIM 7.0: | EC002475 |
| eClass 9.0: | 27-21-01-23 |
| eClass 9.1: | 27-21-01-23 |
| eClass 10.0: | 27-21-01-23 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.198 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |