Article image 1481960000

Weidmueller 1481960000

ACT20P-PRO DCDC II-P

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ACT20P-PRO DCDC II-P
Order No.: 1481960000
Version: Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
GTIN (EAN): 4050118291025
Qty.: 1 pc(s).
Width: 12.5 mm
Width (inches): 0.492 inch
Height: 127.1 mm
Height (inches): 5.004 inch
Depth: 113.7 mm
Depth (inches): 4.476 inch
Weight: 130 g
Net weight: 20 g
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Input signal: Voltage source, Current source
Input voltage: configurable, ±40 mV…±300 V, Measuring range. min 40 mV
Input resistance, voltage: approx. 1 MΩ
Input current: configurable, ± 0.1mA...± 100 mA, Measuring range min. 200 µA
Input resistance, current: < 5 mA: approx. 100 Ω; >5 mA: approx. 5 Ω
Output voltage, note: Adjustable, 0...±10 V
Output current: Adjustable, 0...±20 mA
Cut-off frequency (-3 dB): > 10 kHz/ < 10 Hz
load impedance voltage: ≥ 1 kΩ
Load impedance current: ≤ 600 Ω
Offset voltage: < 10 mV
Offset current: 20 µA
Status indicator: Green LED
Type: Dot-matrix display with ticker text, green
Display value: current measured value, Configuration data
Accuracy: < 0.05 % of measuring range
Configuration: DIP switch, or via display and push-buttons
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Power consumption: ≤2.3 W
Rail: TS 35
Step response time: ≤50 µs
Temperature coefficient: ≤0.01% of the output measurement range ⁄ °C
Voltage supply: 24…230 V DC ±20 %, 24…230 V AC ±10 % @ 48…62 Hz
EMC standards: EN 60079-0, EN 60079-15, EN 61010-1, EN 61140, EN 61326-1, UL 61010-1, SN29500 for MTBF
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage: 5 kV (1.2/50 µs)
Pollution severity: 2
Rated voltage: 600 V
Surge voltage category: II
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-20
eClass 10.0: 27-21-01-20
Approvals: CULUS;GERMLLOYD;
ROHS: Conform
Type: ACT20P-PRO DCDC II-P
Order No.: 1481960000
Version: Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
GTIN (EAN): 4050118291025
Qty.: 1 pc(s).
Width: 12.5 mm
Width (inches): 0.492 inch
Height: 127.1 mm
Height (inches): 5.004 inch
Depth: 113.7 mm
Depth (inches): 4.476 inch
Weight: 130 g
Net weight: 20 g
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Input signal: Voltage source, Current source
Input voltage: configurable, ±40 mV…±300 V, Measuring range. min 40 mV
Input resistance, voltage: approx. 1 MΩ
Input current: configurable, ± 0.1mA...± 100 mA, Measuring range min. 200 µA
Input resistance, current: < 5 mA: approx. 100 Ω; >5 mA: approx. 5 Ω
Output voltage, note: Adjustable, 0...±10 V
Output current: Adjustable, 0...±20 mA
Cut-off frequency (-3 dB): > 10 kHz/ < 10 Hz
load impedance voltage: ≥ 1 kΩ
Load impedance current: ≤ 600 Ω
Offset voltage: < 10 mV
Offset current: 20 µA
Status indicator: Green LED
Type: Dot-matrix display with ticker text, green
Display value: current measured value, Configuration data
Accuracy: < 0.05 % of measuring range
Configuration: DIP switch, or via display and push-buttons
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Power consumption: ≤2.3 W
Rail: TS 35
Step response time: ≤50 µs
Temperature coefficient: ≤0.01% of the output measurement range ⁄ °C
Voltage supply: 24…230 V DC ±20 %, 24…230 V AC ±10 % @ 48…62 Hz
EMC standards: EN 60079-0, EN 60079-15, EN 61010-1, EN 61140, EN 61326-1, UL 61010-1, SN29500 for MTBF
Galvanic isolation: 3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage: 5 kV (1.2/50 µs)
Pollution severity: 2
Rated voltage: 600 V
Surge voltage category: II
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: PUSH IN
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.2 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.2 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 2.5 mm²
ETIM 6.0: EC002653
ETIM 7.0: EC002653
eClass 9.0: 27-21-01-20
eClass 9.1: 27-21-01-20
eClass 10.0: 27-21-01-20
Approvals: CULUS;GERMLLOYD;
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.183 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m