Type: PRO MAX 480W 48V 10A
Order No.: 1478250000
Version: Power supply, switch-mode power supply unit, 48 V
GTIN (EAN): 4050118286069
Qty.: 1 pc(s).
Width: 90 mm
Width (inches): 3.543 inch
Height: 130 mm
Height (inches): 5.118 inch
Depth: 150 mm
Depth (inches): 5.905 inch
Net weight: 2,000 g
Humidity at operating temperature: 5...95 %, no condensation
Operating temperature, max.: 70 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...70 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E255651
Altitude: 3000m, 3000-6000m derating, @ 6000m 75% Load
AC current consumption: 2,3A @ 230 VAC / 4,8A @ 115 VAC
AC input voltage range: 85…277 V AC
Connection system: Screw connection
DC current consumption: 1,5A @ 370 VDC / 4.8A @ 120 VDC
DC input voltage range: 80...370 V DC
Frequency range AC: 45…65 Hz
Input fuse (internal): Yes
Inrush current: max. 15 A
Rated input voltage: 100...240 V AC (wide-range input)
Recommended back-up fuse: 16 A, char. B circuit breaker, 10 A, Char. C circuit breaker
Standby power consumption, max.: 1 W
Surge protection: Varistor
Connection system: Screw connection
Continous output current @ UNominal: 12 A @ 45°C, 7,5 A @ 70°C
Current capacity (pulse) @ UNominal: 60 A (2ms)
Nominal output current for Unom: 10 A @ 60 °C
Output power: 480 W
Output voltage: 48 V
Output voltage: 30...56 V (adjustable via potentiometer)
Parallel connection option: yes, max. 5
Protection against inverse voltage: Yes
Rated output voltage: 48 V DC ± 1 %
Reserve capacity @ UNominal: 12 A (1 min), 15 A (4s), 100…240 V AC
AC failure bridging time @ Inom: min. 20 ms
Degree of efficiency: 93%
Derating: > 60°C / 75% @ 70°C
Earth leakage current, max.: 3.5 mA
Housing version: Metal, corrosion resistant
MTBF: >500.000h (25°C, IEC 61709 (SN29500))
Mounting position, installation notice: Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Operating temperature: -25 °C...70 °C
Power factor (approx.): > 0.95 @ 230 V AC
Power loss, idling: 4.8 W
Power loss, nominal load: 36.1 W
Protection against reverse voltages from the load: 58…65 V DC
Protection degree: IP20
Series switching capability: No
Short-circuit protection: Yes
Start-up: ≥ -40 °C
Status indication: LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off)
Surge voltage category: III
Noise emission in accordance with EN55032: Class B
Vibration resistance IEC 60068-2-6: 2.3 g
Interference immunity test acc. to: EN 55024, EN 55032, IEC61000-3-2,-3, IEC61000-4-2,-3,-4,-5,-6,-8,-11
Shock resistance IEC 60068-2-27: 30 g in all directions
Humidity at operating temperature: 5...95 %, no condensation
Insulation voltage input / earth: 3.5 kV
Insulation voltage output / earth: 0.5 kV
Insulation voltage, input/output: 4 kV
Pollution severity: 2
Protection class: I, with PE connection
Surge voltage category: III
Electrical machine equipment: Acc. to EN60204
For use with electronic equipment: Acc. to EN50178 / VDE0160
Protection against dangerous shock currents: Acc. to VDE0106-101
Protective separation / protection against electrical shock: VDE0100-410 / acc. to DIN57100-410
Safety extra-low voltage: SELV according to EN 60950, PELV according to EN 60204, IEC61204
Safety transformers for switch-mode power supplies: According to EN 61558-2-16
Conductor cross-section, AWG/kcmil , max.: 10
Conductor cross-section, AWG/kcmil , min.: 26
Conductor cross-section, flexible , min.: 0.22 mm²
Conductor cross-section, rigid , max.: 6 mm²
Conductor cross-section, rigid , min.: 0.18 mm²
Connection system: Screw connection
Number of terminals: 3 for L/N/PE
Screwdriver blade: 0.8 x 4.0, PZ 1
Tightening torque, max.: 0.6 Nm
Tightening torque, min.: 0.5 Nm
Wire connection cross section, flexible (input), max.: 4 mm²
Conductor cross-section, AWG/kcmil , max.: 10
Conductor cross-section, AWG/kcmil , min.: 26
Conductor cross-section, flexible , max.: 4 mm²
Conductor cross-section, flexible , min.: 0.22 mm²
Conductor cross-section, rigid , max.: 6 mm²
Conductor cross-section, rigid , min.: 0.18 mm²
Connection system: Screw connection
Number of terminals: 8 (++,---,11,13,14)
Screwdriver blade: 0.8 x 4.0, PZ 1
Tightening torque, max.: 0.6 Nm
Tightening torque, min.: 0.5 Nm
Contact load (NO contact): max. 30 V DC / 1 A
Floating contact: Yes
Status indication: LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off)
Certificate No. (GERMLLOYD): TAA00000TT
Certificate no. (cULus): E258476
Certificate no. (cULusEX): E470829
Certificate No. (cURus): E255651
ETIM 6.0: EC002540
ETIM 7.0: EC002540
eClass 9.0: 27-04-07-01
eClass 9.1: 27-04-07-01
eClass 10.0: 27-04-07-01
ROHS: Conform
Type: PRO MAX 480W 48V 10A
Order No.: 1478250000
Version: Power supply, switch-mode power supply unit, 48 V
GTIN (EAN): 4050118286069
Qty.: 1 pc(s).
Width: 90 mm
Width (inches): 3.543 inch
Height: 130 mm
Height (inches): 5.118 inch
Depth: 150 mm
Depth (inches): 5.905 inch
Net weight: 2,000 g
Humidity at operating temperature: 5...95 %, no condensation
Operating temperature, max.: 70 °C
Operating temperature, min.: -25 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -25 °C...70 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E255651
Altitude: 3000m, 3000-6000m derating, @ 6000m 75% Load
AC current consumption: 2,3A @ 230 VAC / 4,8A @ 115 VAC
AC input voltage range: 85…277 V AC
Connection system: Screw connection
DC current consumption: 1,5A @ 370 VDC / 4.8A @ 120 VDC
DC input voltage range: 80...370 V DC
Frequency range AC: 45…65 Hz
Input fuse (internal): Yes
Inrush current: max. 15 A
Rated input voltage: 100...240 V AC (wide-range input)
Recommended back-up fuse: 16 A, char. B circuit breaker, 10 A, Char. C circuit breaker
Standby power consumption, max.: 1 W
Surge protection: Varistor
Connection system: Screw connection
Continous output current @ UNominal: 12 A @ 45°C, 7,5 A @ 70°C
Current capacity (pulse) @ UNominal: 60 A (2ms)
Nominal output current for Unom: 10 A @ 60 °C
Output power: 480 W
Output voltage: 48 V
Output voltage: 30...56 V (adjustable via potentiometer)
Parallel connection option: yes, max. 5
Protection against inverse voltage: Yes
Rated output voltage: 48 V DC ± 1 %
Reserve capacity @ UNominal: 12 A (1 min), 15 A (4s), 100…240 V AC
AC failure bridging time @ Inom: min. 20 ms
Degree of efficiency: 93%
Derating: > 60°C / 75% @ 70°C
Earth leakage current, max.: 3.5 mA
Housing version: Metal, corrosion resistant
MTBF: >500.000h (25°C, IEC 61709 (SN29500))
Mounting position, installation notice: Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Operating temperature: -25 °C...70 °C
Power factor (approx.): > 0.95 @ 230 V AC
Power loss, idling: 4.8 W
Power loss, nominal load: 36.1 W
Protection against reverse voltages from the load: 58…65 V DC
Protection degree: IP20
Series switching capability: No
Short-circuit protection: Yes
Start-up: ≥ -40 °C
Status indication: LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off)
Surge voltage category: III
Noise emission in accordance with EN55032: Class B
Vibration resistance IEC 60068-2-6: 2.3 g
Interference immunity test acc. to: EN 55024, EN 55032, IEC61000-3-2,-3, IEC61000-4-2,-3,-4,-5,-6,-8,-11
Shock resistance IEC 60068-2-27: 30 g in all directions
Humidity at operating temperature: 5...95 %, no condensation
Insulation voltage input / earth: 3.5 kV
Insulation voltage output / earth: 0.5 kV
Insulation voltage, input/output: 4 kV
Pollution severity: 2
Protection class: I, with PE connection
Surge voltage category: III
Electrical machine equipment: Acc. to EN60204
For use with electronic equipment: Acc. to EN50178 / VDE0160
Protection against dangerous shock currents: Acc. to VDE0106-101
Protective separation / protection against electrical shock: VDE0100-410 / acc. to DIN57100-410
Safety extra-low voltage: SELV according to EN 60950, PELV according to EN 60204, IEC61204
Safety transformers for switch-mode power supplies: According to EN 61558-2-16
Conductor cross-section, AWG/kcmil , max.: 10
Conductor cross-section, AWG/kcmil , min.: 26
Conductor cross-section, flexible , min.: 0.22 mm²
Conductor cross-section, rigid , max.: 6 mm²
Conductor cross-section, rigid , min.: 0.18 mm²
Connection system: Screw connection
Number of terminals: 3 for L/N/PE
Screwdriver blade: 0.8 x 4.0, PZ 1
Tightening torque, max.: 0.6 Nm
Tightening torque, min.: 0.5 Nm
Wire connection cross section, flexible (input), max.: 4 mm²
Conductor cross-section, AWG/kcmil , max.: 10
Conductor cross-section, AWG/kcmil , min.: 26
Conductor cross-section, flexible , max.: 4 mm²
Conductor cross-section, flexible , min.: 0.22 mm²
Conductor cross-section, rigid , max.: 6 mm²
Conductor cross-section, rigid , min.: 0.18 mm²
Connection system: Screw connection
Number of terminals: 8 (++,---,11,13,14)
Screwdriver blade: 0.8 x 4.0, PZ 1
Tightening torque, max.: 0.6 Nm
Tightening torque, min.: 0.5 Nm
Contact load (NO contact): max. 30 V DC / 1 A
Floating contact: Yes
Status indication: LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off)
Certificate No. (GERMLLOYD): TAA00000TT
Certificate no. (cULus): E258476
Certificate no. (cULusEX): E470829
Certificate No. (cURus): E255651
ETIM 6.0: EC002540
ETIM 7.0: EC002540
eClass 9.0: 27-04-07-01
eClass 9.1: 27-04-07-01
eClass 10.0: 27-04-07-01
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 2.182 kg
Length: 0.00 m
Width: 0.00 m