Article image 1473440000

Weidmueller 1473440000

VPU II 1 1000V/40KA AC

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VPU II 1 1000V/40KA AC
Order No.: 1473440000
Version: Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase
GTIN (EAN): 4050118279689
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 194.22 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 1TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 830 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 1000 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 40 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Protection level Up at IN (L/N-PE): ≤ 3.8 kV
Leakage current at Un: 0.7 mA
Temporary surge voltage (over-voltage) - TOV: 1,205 V
Number of poles: 1
Requirements category acc. to IEC 61643-11: Type II
Requirements class, acc. to EN 61643-11: T2
Response time: ≤ 25 ns
Signalling contact: No
Wire connection method: Screw connection
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pole lightning arrester in accordance with level II requirements (IEC 61643-11, EN61643-11:2013). The arrester provides overvoltage protection in applications in acc. with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for level II surge protection devices (SPD) on the basis of the standards. The arrester is installed in the vicinity of the power supply for the equipment requiring protection, in a commercially available installation/electrical distribution housing. The VPU II 1 1000 V/40 kA AC is used in the single-phase mains network. With thermal cut-off mechanism on the varistor. In case of insufficient protection, the colour in the display window changes from green to red. Rated voltage: 1000V AC In/max (8/20µs): 20/40 kA protection level < 3.8 kV 25 kA short-circuit strength with max. backup fuse of 250A of the same type: Weidmüller VPU II 1 1000V/40KA AC Order no. 1473440000 or equivalent.
Short specification: Class II arrester with In/Imax: 20/40 kA, suitable for single-phase 1000 V mains systems. Protection level < 3.8 kV. Type: Weidmüller VPU II 1 1000V/40KA AC, Order no. 1473440000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VPU II 1 1000V/40KA AC
Order No.: 1473440000
Version: Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase
GTIN (EAN): 4050118279689
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 194.22 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 1TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 830 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 1000 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 20 kA
Discharge current Imax (8/20µs) wire-PE: 40 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: 125 A gL > (if back up fuse > 125 A), No Fuse neccessary ≤125 A gG
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Protection level Up at IN (L/N-PE): ≤ 3.8 kV
Leakage current at Un: 0.7 mA
Temporary surge voltage (over-voltage) - TOV: 1,205 V
Number of poles: 1
Requirements category acc. to IEC 61643-11: Type II
Requirements class, acc. to EN 61643-11: T2
Response time: ≤ 25 ns
Signalling contact: No
Wire connection method: Screw connection
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pole lightning arrester in accordance with level II requirements (IEC 61643-11, EN61643-11:2013). The arrester provides overvoltage protection in applications in acc. with IEC 61643-12. The use of a high-performance varistor meets the inspection requirements for level II surge protection devices (SPD) on the basis of the standards. The arrester is installed in the vicinity of the power supply for the equipment requiring protection, in a commercially available installation/electrical distribution housing. The VPU II 1 1000 V/40 kA AC is used in the single-phase mains network. With thermal cut-off mechanism on the varistor. In case of insufficient protection, the colour in the display window changes from green to red. Rated voltage: 1000V AC In/max (8/20µs): 20/40 kA protection level < 3.8 kV 25 kA short-circuit strength with max. backup fuse of 250A of the same type: Weidmüller VPU II 1 1000V/40KA AC Order no. 1473440000 or equivalent.
Short specification: Class II arrester with In/Imax: 20/40 kA, suitable for single-phase 1000 V mains systems. Protection level < 3.8 kV. Type: Weidmüller VPU II 1 1000V/40KA AC, Order no. 1473440000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.213 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m