1435590000
ACT20M-RTCI-CO-OLP-S
| Type: | ACT20M-RTCI-CO-OLP-S |
| Order No.: | 1435590000 |
| Version: | Temperature converter, 2-/3-/4- wire RTD, Thermocouple, Input : Temperature, Output : 4-20 mA, (loop powered) |
| GTIN (EAN): | 4050118240641 |
| Qty.: | 1 pc(s). |
| Width: | 6.1 |
| Width (inches): | 0.24 inch |
| Height: | 112.5 mm |
| Height (inches): | 4.429 inch |
| Depth: | 114.3 mm |
| Depth (inches): | 4.5 inch |
| Net weight: | 80 g |
| Humidity: | 40 °C / 93 % rel. humidity, no condensation |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Ambient temperature: | -25 °C...+70 °C |
| Storage temperature: | -40 °C...85 °C |
| MTBF: | 207 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Sensor: | PT100 / 2-/3-/4-wire, Thermocouple acc. to IEC 584, type: J, Thermocouple acc. to IEC 584, type: K |
| Influence of the sensor cable resistance: | < 0.002 Ω⁄Ω |
| Input measurement range: | PT100 -200…+850 °C, Thermocouple type J -100…+1200°C, Thermocouple type K -200…+1370°C |
| Line resistance in measuring circuit: | 50 Ω@ RTD (Pt100), 10 kΩ @ TC (J, K) |
| Temperature input range: | Configurable, min. measurement range 10°C (RTD), min. measurement range 50°C (TC) |
| Number of outputs: | 1 |
| Output current: | configurable, 4...20 mA, 20…4 mA |
| Wire break detection: | 3.5 mA ⁄ 23 mA ⁄ none |
| cold junction compensation: | configurable internal or external cold-junction compensation (thermocouple) |
| Supply voltage (output): | 16,8 V…31,2 V |
| Accuracy: | absolute accuracy: < ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: < ±0.1 °C of the measurement range, TC (J,K) Basic accuracy: < ±0.5 °C of the measurement range |
| Cold-junction compensation error: | ±(2.0 °C + 0.4 °C x Δt) Δt = inside temperature – ambient temperature |
| Configuration: | DIP switch |
| Setting parameters: | Output |
| Configuration: | 4...20 mA (loop) |
| Setting parameters: | Sensor error detection |
| Configuration: | enabled |
| Setting parameters: | Output error level |
| Configuration: | downscale |
| Setting parameters: | Noise suppression |
| Configuration: | 50 Hz |
| Setting parameters: | Step response time |
| Configuration: | < 30 ms |
| Setting parameters: | Start temperature |
| Configuration: | -200 °C |
| Setting parameters: | End temperature |
| Configuration: | 0 °C |
| Galvanic isolation: | 2-way isolator |
| Power consumption, max.: | 0.8 W |
| Power consumption, typ.: | 0.5 W |
| Rail: | TS 35 |
| Step response time: | ≤ 30 ms, < 300 ms |
| Temperature coefficient: | RTD (PT100) ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C, TC (J,K) 0.1 °C ⁄ °C |
| Voltage supply: | Output loop powered, 6…35 V |
| EMC standards: | IEC 61326-1, NE 21 |
| Galvanic isolation: | 2-way isolator |
| Pollution severity: | 2 |
| Surge voltage category: | II |
| Marking: | II 3 G Ex nA IIC T4 Gc |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.6 Nm |
| Clamping range, rated connection: | 2.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 30 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Product information: | The ACT20M-RTCI-CO-OLP-S passive configurable temperature transducer isolates and converts analogue signals. An analogue RTD (Type Pt100) or TC (Type J, K) input signal is linearly converted into an analogue output signal and galvanically isolated. Power is supplied through the output measurement circuit (output- loop powered). |
| ETIM 6.0: | EC002919 |
| ETIM 7.0: | EC002919 |
| eClass 9.0: | 27-21-01-29 |
| eClass 9.1: | 27-21-01-29 |
| eClass 10.0: | 27-21-01-29 |
| ROHS: | Conform |
| Type: | ACT20M-RTCI-CO-OLP-S |
| Order No.: | 1435590000 |
| Version: | Temperature converter, 2-/3-/4- wire RTD, Thermocouple, Input : Temperature, Output : 4-20 mA, (loop powered) |
| GTIN (EAN): | 4050118240641 |
| Qty.: | 1 pc(s). |
| Width: | 6.1 |
| Width (inches): | 0.24 inch |
| Height: | 112.5 mm |
| Height (inches): | 4.429 inch |
| Depth: | 114.3 mm |
| Depth (inches): | 4.5 inch |
| Net weight: | 80 g |
| Humidity: | 40 °C / 93 % rel. humidity, no condensation |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -40 °C |
| Ambient temperature: | -25 °C...+70 °C |
| Storage temperature: | -40 °C...85 °C |
| MTBF: | 207 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Number of inputs: | 1 |
| Sensor: | PT100 / 2-/3-/4-wire, Thermocouple acc. to IEC 584, type: J, Thermocouple acc. to IEC 584, type: K |
| Influence of the sensor cable resistance: | < 0.002 Ω⁄Ω |
| Input measurement range: | PT100 -200…+850 °C, Thermocouple type J -100…+1200°C, Thermocouple type K -200…+1370°C |
| Line resistance in measuring circuit: | 50 Ω@ RTD (Pt100), 10 kΩ @ TC (J, K) |
| Temperature input range: | Configurable, min. measurement range 10°C (RTD), min. measurement range 50°C (TC) |
| Number of outputs: | 1 |
| Output current: | configurable, 4...20 mA, 20…4 mA |
| Wire break detection: | 3.5 mA ⁄ 23 mA ⁄ none |
| cold junction compensation: | configurable internal or external cold-junction compensation (thermocouple) |
| Supply voltage (output): | 16,8 V…31,2 V |
| Accuracy: | absolute accuracy: < ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: < ±0.1 °C of the measurement range, TC (J,K) Basic accuracy: < ±0.5 °C of the measurement range |
| Cold-junction compensation error: | ±(2.0 °C + 0.4 °C x Δt) Δt = inside temperature – ambient temperature |
| Configuration: | DIP switch |
| Setting parameters: | Output |
| Configuration: | 4...20 mA (loop) |
| Setting parameters: | Sensor error detection |
| Configuration: | enabled |
| Setting parameters: | Output error level |
| Configuration: | downscale |
| Setting parameters: | Noise suppression |
| Configuration: | 50 Hz |
| Setting parameters: | Step response time |
| Configuration: | < 30 ms |
| Setting parameters: | Start temperature |
| Configuration: | -200 °C |
| Setting parameters: | End temperature |
| Configuration: | 0 °C |
| Galvanic isolation: | 2-way isolator |
| Power consumption, max.: | 0.8 W |
| Power consumption, typ.: | 0.5 W |
| Rail: | TS 35 |
| Step response time: | ≤ 30 ms, < 300 ms |
| Temperature coefficient: | RTD (PT100) ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C, TC (J,K) 0.1 °C ⁄ °C |
| Voltage supply: | Output loop powered, 6…35 V |
| EMC standards: | IEC 61326-1, NE 21 |
| Galvanic isolation: | 2-way isolator |
| Pollution severity: | 2 |
| Surge voltage category: | II |
| Marking: | II 3 G Ex nA IIC T4 Gc |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.4 Nm |
| Tightening torque, max.: | 0.6 Nm |
| Clamping range, rated connection: | 2.5 mm² |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 2.5 mm² |
| Wire connection cross section AWG, min.: | AWG 30 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Product information: | The ACT20M-RTCI-CO-OLP-S passive configurable temperature transducer isolates and converts analogue signals. An analogue RTD (Type Pt100) or TC (Type J, K) input signal is linearly converted into an analogue output signal and galvanically isolated. Power is supplied through the output measurement circuit (output- loop powered). |
| ETIM 6.0: | EC002919 |
| ETIM 7.0: | EC002919 |
| eClass 9.0: | 27-21-01-29 |
| eClass 9.1: | 27-21-01-29 |
| eClass 10.0: | 27-21-01-29 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.088 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |