Article image 1421440000

Weidmueller 1421440000

VSSC6 TR SL FG 24VAC/DC EX

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VSSC6 TR SL FG 24VAC/DC EX
Order No.: 1421440000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4050118225228
Qty.: 1 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 0.081 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 54
MTTF: 1,342 years
PFH in 1*10-9 per hour: 1.8
SFF: 96.67 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 0.75 W
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +120 °C) li: 300 mA
Temperature class T5/100°C (-40 ° C ... +85 °C) li: 300 mA
Temperature class T6/85 °C (-40 °C ... +70 °C) li: 300 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 300 mA
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal
Isolating function: Yes
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
Testing option: Functional screw with test plug receptacle, connections 1, 2, 4, 5
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current Iimp (10/350 µs): 1 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Standards: IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): ≤ 1870 V
Protection level on output side Wire-wire 1 kV/µs, typically: 70 V
Protection level, UP GND - PE: 2,200 V
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 42 V
Insertion loss: 250 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 70 V
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 300 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 270 Mhz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 50 A 10/1000 μs
Surge current-carrying capacity D1: 1 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 12.4 mm wide terminal rail module for a floating-ground, intrinsically safe signal circuit with 48 VUC in 2-wire technology. A current loop with max. 0.6 A can be protected here. Each signal path can be opened using an isolator. When the terminal is fitted, a sparkover gap is simultaneously created to the high-impedance earth between the terminal rail (earth) and the reference potential (ground) of the protective circuit. Optical identification of the terminal based on the type of protective circuit and the voltage level. The terminal can be labelled.
Short specification: Surge protection in a one piece, 12.4 mm wide terminal rail module for an intrinsically safe, floating-ground driven signal circuit with 2-wire technology and a common wire. Each signal path can be opened using an isolator. Version: 48 VUC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSSC6 TR SL FG 24VAC/DC EX
Order No.: 1421440000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4050118225228
Qty.: 1 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 88.5 mm
Height (inches): 3.484 inch
Depth: 81 mm
Depth (inches): 3.189 inch
Net weight: 0.081 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 54
MTTF: 1,342 years
PFH in 1*10-9 per hour: 1.8
SFF: 96.67 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 0.75 W
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +120 °C) li: 300 mA
Temperature class T5/100°C (-40 ° C ... +85 °C) li: 300 mA
Temperature class T6/85 °C (-40 °C ... +70 °C) li: 300 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 300 mA
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 2 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal
Isolating function: Yes
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
Testing option: Functional screw with test plug receptacle, connections 1, 2, 4, 5
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Discharge current In (8/20µs) wire-wire: 2.5 kA
Discharge current Imax (8/20µs) wire-wire: 10 kA
Lightning test current Iimp (10/350 µs): 1 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Standards: IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): ≤ 1870 V
Protection level on output side Wire-wire 1 kV/µs, typically: 70 V
Protection level, UP GND - PE: 2,200 V
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 42 V
Insertion loss: 250 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Protection level, UP wire - wire: 70 V
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 300 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 270 Mhz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 50 A 10/1000 μs
Surge current-carrying capacity D1: 1 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 12.4 mm wide terminal rail module for a floating-ground, intrinsically safe signal circuit with 48 VUC in 2-wire technology. A current loop with max. 0.6 A can be protected here. Each signal path can be opened using an isolator. When the terminal is fitted, a sparkover gap is simultaneously created to the high-impedance earth between the terminal rail (earth) and the reference potential (ground) of the protective circuit. Optical identification of the terminal based on the type of protective circuit and the voltage level. The terminal can be labelled.
Short specification: Surge protection in a one piece, 12.4 mm wide terminal rail module for an intrinsically safe, floating-ground driven signal circuit with 2-wire technology and a common wire. Each signal path can be opened using an isolator. Version: 48 VUC
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.081 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m