Article image 1393050000

Weidmueller 1393050000

VPU III 3/280V

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VPU III 3/280V
Order No.: 1393050000
GTIN (EAN): 4050118193862
Qty.: 1 pc(s).
Width: 70 mm
Width (inches): 2.756 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 57 mm
Depth (inches): 2.244 inch
Net weight: 191 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 70 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...70 °C
Rated current IN: 16 A
Connection type: Screw connection
Max. torque: 0.22 Nm
Stripping length: 5 mm
Cross-section for connected wire, solid core, min.: 0.2 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: grey
Design: Installation housing; 1TE, Insta IP 20
Optical function display: Green LED = OK, Red LED = arrester is defective, replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: with remote contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 230 V
Voltage type: 3-phase 230/400 V
Max. continuous voltage, Uc (AC): 275 V
Low voltage network: TN-C, TN-S, TN-C-S
Discharge current Imax (8/20µs) wire-PE: 3 kA
Fuse: 16 A
Short-circuit current rating ISCCR: 1.5 kA
Protection level UP (typ.): < 1000 V
Protection level Up at IN (L/N-PE): ≤ 1.8 kV
Leakage current at Un: 30 µA
Temporary surge voltage (over-voltage) - TOV: 440 V
Combined pulse UOC: 6 kV
Mains frequency at 250 Vmax: 50...60Hz
Number of poles: 1
PE conductor current IPE: 30 µA
Rated current IN: 16 A
Requirements category acc. to IEC 61643-11: Type III
Requirements class, acc. to EN 61643-11: T3
Response time: ≤ 100 ns
Signalling contact: 250 V 10 A 1 NC
Type of connection: Screw connection
Stripping length, rated connection: 7 mm
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.5 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.5 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 2.5 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 2.5 mm²
Long specification: Three-pin surge protection according to the requirements of Class III in accordance with IEC 61643-11, EN61643-11:2013. The arrester serves as surge protection and is used in applications in accordance with IEC 61643-12. The arrester is installed in a standard installation/distributor housing in the vicinity of the equipment that needs protection. The VPU III 3 280 V is earthed between the outer conductors (L1, L2, L3 and the neutral conductor). With thermal separation device on the varistor. If there is no longer any protection, the colour of the LEDs changes from green to red. The functional state is also displayed by a voltage-free signalling contact (NC contact). Rated voltage: 230 V AC In/max (8/20 µs):3 kA protection level < 1.8 kV load current Il: 16A  telecommunication output: contact NC: 250 V/0.5 A 48 V DC/0.1 A Type: Weidmüller VPU  III 3 280 V Order No. 1393050000 or equivalent
Short specification: Class III arrester with Uoc: 6 kV suitable for 230/400 V TN-S mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU III 3 280 V Order no. 1393050000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VPU III 3/280V
Order No.: 1393050000
GTIN (EAN): 4050118193862
Qty.: 1 pc(s).
Width: 70 mm
Width (inches): 2.756 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 57 mm
Depth (inches): 2.244 inch
Net weight: 191 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 70 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...70 °C
Rated current IN: 16 A
Connection type: Screw connection
Max. torque: 0.22 Nm
Stripping length: 5 mm
Cross-section for connected wire, solid core, min.: 0.2 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: grey
Design: Installation housing; 1TE, Insta IP 20
Optical function display: Green LED = OK, Red LED = arrester is defective, replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
UL 94 flammability rating: V-0
Version: with remote contact
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 230 V
Voltage type: 3-phase 230/400 V
Max. continuous voltage, Uc (AC): 275 V
Low voltage network: TN-C, TN-S, TN-C-S
Discharge current Imax (8/20µs) wire-PE: 3 kA
Fuse: 16 A
Short-circuit current rating ISCCR: 1.5 kA
Protection level UP (typ.): < 1000 V
Protection level Up at IN (L/N-PE): ≤ 1.8 kV
Leakage current at Un: 30 µA
Temporary surge voltage (over-voltage) - TOV: 440 V
Combined pulse UOC: 6 kV
Mains frequency at 250 Vmax: 50...60Hz
Number of poles: 1
PE conductor current IPE: 30 µA
Rated current IN: 16 A
Requirements category acc. to IEC 61643-11: Type III
Requirements class, acc. to EN 61643-11: T3
Response time: ≤ 100 ns
Signalling contact: 250 V 10 A 1 NC
Type of connection: Screw connection
Stripping length, rated connection: 7 mm
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.5 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.5 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 2.5 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 2.5 mm²
Long specification: Three-pin surge protection according to the requirements of Class III in accordance with IEC 61643-11, EN61643-11:2013. The arrester serves as surge protection and is used in applications in accordance with IEC 61643-12. The arrester is installed in a standard installation/distributor housing in the vicinity of the equipment that needs protection. The VPU III 3 280 V is earthed between the outer conductors (L1, L2, L3 and the neutral conductor). With thermal separation device on the varistor. If there is no longer any protection, the colour of the LEDs changes from green to red. The functional state is also displayed by a voltage-free signalling contact (NC contact). Rated voltage: 230 V AC In/max (8/20 µs):3 kA protection level < 1.8 kV load current Il: 16A  telecommunication output: contact NC: 250 V/0.5 A 48 V DC/0.1 A Type: Weidmüller VPU  III 3 280 V Order No. 1393050000 or equivalent
Short specification: Class III arrester with Uoc: 6 kV suitable for 230/400 V TN-S mains systems. Protection level < 1.8 kV. With remote alert Type: Weidmüller VPU III 3 280 V Order no. 1393050000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.191 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m