Article image 1375520000

Weidmueller 1375520000

ACT20M-RTI-AO-E-S

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ACT20M-RTI-AO-E-S
Order No.: 1375520000
Version: Temperature converter, 2-/3-/4- wire RTD, Without galvanic isolation, Input : Temperature, Output : I / U
GTIN (EAN): 4050118259681
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 86 g
Humidity: 95 %, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 195 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: PT100 / 2-/3-/4-wire
Influence of the sensor cable resistance: < 0.002 Ω⁄Ω (@ 3⁄4-wire)
Input measurement range: PT100 -200…+850 °C
Line resistance in measuring circuit: ≤ 50 Ω
Temperature input range: Configurable, min. measurement range 10°C (RTD)
Number of outputs: 1
Output signal limit: < 4 mA (average), < 60 mA (pulse current), low duty cycle
Output voltage, note: configurable, 0(2)...10 V, 0(1)...5 V
Output current: configurable, 0...20 mA, 4...20 mA
Wire break detection: 3.5 mA ⁄ 23 mA ⁄ none
load impedance voltage: ≥ 10 kΩ
Load impedance current: ≤ 600 Ω
Accuracy: absolute accuracy: < ±0.1 % of the measurement range
Configuration: DIP switch
Setting parameters: Output
Configuration: 4...20 mA
Setting parameters: Sensor error detection
Configuration: enabled
Setting parameters: Output error level
Configuration: downscale
Setting parameters: Noise suppression
Configuration: 50 Hz
Setting parameters: Step response time
Configuration: < 30 ms
Setting parameters: Start temperature
Configuration: -200 °C
Setting parameters: End temperature
Configuration: 0 °C
Galvanic isolation: Without isolation
Power consumption, max.: 0.5 W
Power consumption, typ.: 0.37 W
Rail: TS 35
Step response time: ≤ 30 ms
Temperature coefficient: ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: Without isolation
Pollution severity: 2
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
ETIM 6.0: EC002919
ETIM 7.0: EC002919
eClass 9.0: 27-21-01-29
eClass 9.1: 27-21-01-29
eClass 10.0: 27-21-01-29
ROHS: Conform
Type: ACT20M-RTI-AO-E-S
Order No.: 1375520000
Version: Temperature converter, 2-/3-/4- wire RTD, Without galvanic isolation, Input : Temperature, Output : I / U
GTIN (EAN): 4050118259681
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 86 g
Humidity: 95 %, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 195 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: PT100 / 2-/3-/4-wire
Influence of the sensor cable resistance: < 0.002 Ω⁄Ω (@ 3⁄4-wire)
Input measurement range: PT100 -200…+850 °C
Line resistance in measuring circuit: ≤ 50 Ω
Temperature input range: Configurable, min. measurement range 10°C (RTD)
Number of outputs: 1
Output signal limit: < 4 mA (average), < 60 mA (pulse current), low duty cycle
Output voltage, note: configurable, 0(2)...10 V, 0(1)...5 V
Output current: configurable, 0...20 mA, 4...20 mA
Wire break detection: 3.5 mA ⁄ 23 mA ⁄ none
load impedance voltage: ≥ 10 kΩ
Load impedance current: ≤ 600 Ω
Accuracy: absolute accuracy: < ±0.1 % of the measurement range
Configuration: DIP switch
Setting parameters: Output
Configuration: 4...20 mA
Setting parameters: Sensor error detection
Configuration: enabled
Setting parameters: Output error level
Configuration: downscale
Setting parameters: Noise suppression
Configuration: 50 Hz
Setting parameters: Step response time
Configuration: < 30 ms
Setting parameters: Start temperature
Configuration: -200 °C
Setting parameters: End temperature
Configuration: 0 °C
Galvanic isolation: Without isolation
Power consumption, max.: 0.5 W
Power consumption, typ.: 0.37 W
Rail: TS 35
Step response time: ≤ 30 ms
Temperature coefficient: ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: Without isolation
Pollution severity: 2
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
ETIM 6.0: EC002919
ETIM 7.0: EC002919
eClass 9.0: 27-21-01-29
eClass 9.1: 27-21-01-29
eClass 10.0: 27-21-01-29
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.086 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m