Article image 1375510000

Weidmueller 1375510000

ACT20M-RTI-AO-S

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: ACT20M-RTI-AO-S
Order No.: 1375510000
Version: Temperature converter, 2-/3-/4- wire RTD, With galvanic isolation, Input : Temperature, Output : I / U
GTIN (EAN): 4050118259667
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 89 g
Humidity: 95 %, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 152 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: PT100 / 2-/3-/4-wire
Influence of the sensor cable resistance: < 0.002 Ω⁄Ω (@ 3⁄4-wire)
Input measurement range: PT100 -200…+850 °C
Line resistance in measuring circuit: ≤ 50 Ω
Temperature input range: Configurable, min. measurement range 10°C (RTD)
Number of outputs: 1
Output signal limit: < 4 mA (average), < 60 mA (pulse current), low duty cycle
Output voltage, note: configurable, 0(2)...10 V, 0(1)...5 V
Output current: configurable, 0...20 mA, 4...20 mA
Wire break detection: 3.5 mA ⁄ 23 mA ⁄ none
load impedance voltage: ≥ 10 kΩ
Load impedance current: ≤ 600 Ω
Accuracy: absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.1°C
Configuration: DIP switch
Setting parameters: Output
Configuration: 4...20 mA
Setting parameters: Sensor error detection
Configuration: enabled
Setting parameters: Output error level
Configuration: downscale
Setting parameters: Noise suppression
Configuration: 50 Hz
Setting parameters: Step response time
Configuration: < 30 ms
Setting parameters: Start temperature
Configuration: -200 °C
Setting parameters: End temperature
Configuration: 0 °C
Galvanic isolation: 3-way isolator
Power consumption, max.: 0.7 W
Power consumption, typ.: 0.49 W
Rail: TS 35
Step response time: ≤ 30 ms
Temperature coefficient: ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: 3-way isolator
Pollution severity: 2
Surge voltage category: II
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
Product information: The ACT20M-RTI-AO-S configurable temperature transducer isolates and converts analogue signals. An analogue RTD input signal (Type Pt100) is linearly converted into an analogue output signal and galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation) and this is done with direct wiring or over the Weidmüller rail bus.
ETIM 6.0: EC002919
ETIM 7.0: EC002919
eClass 9.0: 27-21-01-29
eClass 9.1: 27-21-01-29
eClass 10.0: 27-21-01-29
ROHS: Conform
Type: ACT20M-RTI-AO-S
Order No.: 1375510000
Version: Temperature converter, 2-/3-/4- wire RTD, With galvanic isolation, Input : Temperature, Output : I / U
GTIN (EAN): 4050118259667
Qty.: 1 pc(s).
Width: 6.1
Width (inches): 0.24 inch
Height: 112.5 mm
Height (inches): 4.429 inch
Depth: 114.3 mm
Depth (inches): 4.5 inch
Net weight: 89 g
Humidity: 95 %, no condensation
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Ambient temperature: -25 °C...+70 °C
Storage temperature: -40 °C...85 °C
MTBF: 152 Years
REACH SVHC: Lead 7439-92-1
Number of inputs: 1
Sensor: PT100 / 2-/3-/4-wire
Influence of the sensor cable resistance: < 0.002 Ω⁄Ω (@ 3⁄4-wire)
Input measurement range: PT100 -200…+850 °C
Line resistance in measuring circuit: ≤ 50 Ω
Temperature input range: Configurable, min. measurement range 10°C (RTD)
Number of outputs: 1
Output signal limit: < 4 mA (average), < 60 mA (pulse current), low duty cycle
Output voltage, note: configurable, 0(2)...10 V, 0(1)...5 V
Output current: configurable, 0...20 mA, 4...20 mA
Wire break detection: 3.5 mA ⁄ 23 mA ⁄ none
load impedance voltage: ≥ 10 kΩ
Load impedance current: ≤ 600 Ω
Accuracy: absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.1°C
Configuration: DIP switch
Setting parameters: Output
Configuration: 4...20 mA
Setting parameters: Sensor error detection
Configuration: enabled
Setting parameters: Output error level
Configuration: downscale
Setting parameters: Noise suppression
Configuration: 50 Hz
Setting parameters: Step response time
Configuration: < 30 ms
Setting parameters: Start temperature
Configuration: -200 °C
Setting parameters: End temperature
Configuration: 0 °C
Galvanic isolation: 3-way isolator
Power consumption, max.: 0.7 W
Power consumption, typ.: 0.49 W
Rail: TS 35
Step response time: ≤ 30 ms
Temperature coefficient: ≤0.01 % of the measurement range⁄°C or 0.02 °C ⁄ °C
Voltage supply: 24 V DC ± 30 %
EMC standards: IEC 61326-1, NE 21
Galvanic isolation: 3-way isolator
Pollution severity: 2
Surge voltage category: II
Marking: II 3 G Ex nA IIC T4 Gc
Type of connection: Screw connection
Tightening torque, min.: 0.4 Nm
Tightening torque, max.: 0.6 Nm
Clamping range, rated connection: 2.5 mm²
Clamping range, min.: 0.5 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 30
Wire connection cross section AWG, max.: AWG 14
Product information: The ACT20M-RTI-AO-S configurable temperature transducer isolates and converts analogue signals. An analogue RTD input signal (Type Pt100) is linearly converted into an analogue output signal and galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation) and this is done with direct wiring or over the Weidmüller rail bus.
ETIM 6.0: EC002919
ETIM 7.0: EC002919
eClass 9.0: 27-21-01-29
eClass 9.1: 27-21-01-29
eClass 10.0: 27-21-01-29
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.09 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m