1354790000
VSSC6TRSL24VAC/DC0.5A
| Type: | VSSC6TRSL24VAC/DC0.5A |
| Order No.: | 1354790000 |
| Version: | Surge protection for instrumentation and control, 24 V, 34 V, 500 mA, IEC 61643-21 |
| GTIN (EAN): | 4050118156744 |
| Qty.: | 10 pc(s). |
| Width: | 6.2 mm |
| Width (inches): | 0.244 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 47 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 54 |
| MTTF: | 1,358 years |
| PFH in 1*10-9 per hour: | 1.8 |
| SFF: | 96.67 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Altitude: | ≤ 2000 m |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 500 mA |
| Input voltage, max. Ui: | 42 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Altitude: | ≤ 2000 m |
| Colour: | black |
| Design: | Terminal |
| Isolating function: | Yes |
| Optical function display: | No |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| Testing option: | Functional screw with test plug receptacle, connections 1, 2, 4, 5 |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 34 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 30 V |
| Max. continuous voltage, Uc (DC): | 42 V |
| Discharge current, max. (8/20 µs): | 20 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Lightning test current Iimp (10/350 µs): | 1 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 1 kA |
| Fuse: | 0.5 A |
| Standards: | IEC 61643-21 |
| Protection level UP (typ.): | 150 V |
| Protection level UP for C1 with 500V/250A (wire-PE): | 60 V |
| Protection level UP for C2 with 10kV/5kA (wire-PE): | 108 V |
| Protection level UP for C2 with 10kV/5kA (wire-wire): | 204 V |
| Protection level UP for C3 with 1kV/µs (wire-PE): | 55 V |
| Protection level UP for C3 with 1kV/µs (wire-wire): | 106 V |
| Protection level UP for D1 with 0.5kA (wire-wire): | 194 V |
| Leakage current at Un: | 2.8 mA |
| Insertion loss: | 3.12 Mhz |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Protection level UP for C1 with 500V/250A (wire-wire): | 116 V |
| Pulse-reset capacity: | ≤ 20 ms |
| Rated current IN: | 500 mA |
| Requirements category acc. to IEC 61643-21: | C2, C3, D1 |
| Signal transmission properties (-3 dB): | 3.2 MHz |
| Surge current-carrying capacity C2: | 2.5 kA 8/20 µs 5 kV 1.2/50 µs |
| Surge current-carrying capacity C3: | 10 A 10/1000 µs |
| Surge current-carrying capacity D1: | 1 kA 10/350 μs |
| Volume resistance: | 1.8 Ω 10 % |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits with 24 V UC. Each signal path can be opened using an isolator. Signal indication via a green LED. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits. Each signal path can be opened using an isolator. Signal indication via a green LED. Version: 24V UC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSSC6TRSL24VAC/DC0.5A |
| Order No.: | 1354790000 |
| Version: | Surge protection for instrumentation and control, 24 V, 34 V, 500 mA, IEC 61643-21 |
| GTIN (EAN): | 4050118156744 |
| Qty.: | 10 pc(s). |
| Width: | 6.2 mm |
| Width (inches): | 0.244 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 47 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 54 |
| MTTF: | 1,358 years |
| PFH in 1*10-9 per hour: | 1.8 |
| SFF: | 96.67 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Altitude: | ≤ 2000 m |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 500 mA |
| Input voltage, max. Ui: | 42 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Altitude: | ≤ 2000 m |
| Colour: | black |
| Design: | Terminal |
| Isolating function: | Yes |
| Optical function display: | No |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| Testing option: | Functional screw with test plug receptacle, connections 1, 2, 4, 5 |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 34 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 30 V |
| Max. continuous voltage, Uc (DC): | 42 V |
| Discharge current, max. (8/20 µs): | 20 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Lightning test current Iimp (10/350 µs): | 1 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 1 kA |
| Fuse: | 0.5 A |
| Standards: | IEC 61643-21 |
| Protection level UP (typ.): | 150 V |
| Protection level UP for C1 with 500V/250A (wire-PE): | 60 V |
| Protection level UP for C2 with 10kV/5kA (wire-PE): | 108 V |
| Protection level UP for C2 with 10kV/5kA (wire-wire): | 204 V |
| Protection level UP for C3 with 1kV/µs (wire-PE): | 55 V |
| Protection level UP for C3 with 1kV/µs (wire-wire): | 106 V |
| Protection level UP for D1 with 0.5kA (wire-wire): | 194 V |
| Leakage current at Un: | 2.8 mA |
| Insertion loss: | 3.12 Mhz |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Protection level UP for C1 with 500V/250A (wire-wire): | 116 V |
| Pulse-reset capacity: | ≤ 20 ms |
| Rated current IN: | 500 mA |
| Requirements category acc. to IEC 61643-21: | C2, C3, D1 |
| Signal transmission properties (-3 dB): | 3.2 MHz |
| Surge current-carrying capacity C2: | 2.5 kA 8/20 µs 5 kV 1.2/50 µs |
| Surge current-carrying capacity C3: | 10 A 10/1000 µs |
| Surge current-carrying capacity D1: | 1 kA 10/350 μs |
| Volume resistance: | 1.8 Ω 10 % |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits with 24 V UC. Each signal path can be opened using an isolator. Signal indication via a green LED. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits. Each signal path can be opened using an isolator. Signal indication via a green LED. Version: 24V UC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.047 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |