Article image 1351620000

Weidmueller 1351620000

VPU I 2 R LCF 280V/25KA

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VPU I 2 R LCF 280V/25KA
Order No.: 1351620000
Version: Surge voltage arrester, Low voltage, with remote contact, Leakage-current-free, Single-phase
GTIN (EAN): 4050118158526
Qty.: 1 pc(s).
Width: 71.2 mm
Width (inches): 2.803 inch
Height: 106 mm
Height (inches): 4.173 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 714 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Connection type: PUSH IN
Stripping length: 8 mm
Cross-section for connected wire, solid core, min.: 0.14 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black, orange
Design: Installation housing; 4TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
Suitable for: Count-in installation (leakage current free)
UL 94 flammability rating: V-0
Version: with remote contact, Leakage-current-free
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 280 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 100 kA
Lightning test current Iimp (10/350 µs) (L-PE): 25 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.6 kV
Leakage current at Un: 1 µA
Temporary surge voltage (over-voltage) - TOV: 438 V
Number of poles: 2
Rated load current IL: 125 A
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 100 ns
Signalling contact: 250 V 1A 1CO
Suitable for: Count-in installation (leakage current free)
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 4 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 2.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 2.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (acc. to IEC 1312-1), the arrestor serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a non-blow-out sparkover gap, in combination with a high-performance varistor, satisfies the inspection requirements for Class I surge protection systems in accordance with the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 2 R LCF 280 V/25 kA is used in the single-phase mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (chang
Short specification: Class I arrester for LPL I with 25 kA suitable for 230/400 V single-phase TN mains systems. Protection level < 1.6 kV. With remote alert Type: Weidmüller VPU I 2 R LCF 280 V/25 kA Order no. 1351620000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform
Type: VPU I 2 R LCF 280V/25KA
Order No.: 1351620000
Version: Surge voltage arrester, Low voltage, with remote contact, Leakage-current-free, Single-phase
GTIN (EAN): 4050118158526
Qty.: 1 pc(s).
Width: 71.2 mm
Width (inches): 2.803 inch
Height: 106 mm
Height (inches): 4.173 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 714 g
Humidity: 5 - 95% rel. humidity
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Connection type: PUSH IN
Stripping length: 8 mm
Cross-section for connected wire, solid core, min.: 0.14 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black, orange
Design: Installation housing; 4TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
Segment: Power distribution
Suitable for: Count-in installation (leakage current free)
UL 94 flammability rating: V-0
Version: with remote contact, Leakage-current-free
Pollution severity: 2
Surge voltage category: IV
Rated voltage (AC): 230 V
Voltage type: AC
Max. continuous voltage, Uc (AC): 280 V
Low voltage network: Single-phase
Discharge current In (8/20µs) wire-PE: 25 kA
Discharge current Imax (8/20µs) wire-PE: 100 kA
Lightning test current Iimp (10/350 µs) (L-PE): 25 kA
Frequency range, max.: 60 Hz
Frequency range, min.: 50 Hz
Fuse: No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Short-circuit current rating ISCCR: 25 kA
Follow-on current extinguishing capability Ifi: Not available due for technical reasons
Standards: IEC61643-11, EN61643-11
Energy coordination (≤10 m): Type I, Type II, Type III
Protection level Up at IN (L/N-PE): ≤ 1.6 kV
Leakage current at Un: 1 µA
Temporary surge voltage (over-voltage) - TOV: 438 V
Number of poles: 2
Rated load current IL: 125 A
Requirements category acc. to IEC 61643-11: Type I, Type II
Requirements class, acc. to EN 61643-11: T1, T2
Response time: ≤ 100 ns
Signalling contact: 250 V 1A 1CO
Suitable for: Count-in installation (leakage current free)
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 4 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 2.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 2.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 2.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (acc. to IEC 1312-1), the arrestor serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. The use of a non-blow-out sparkover gap, in combination with a high-performance varistor, satisfies the inspection requirements for Class I surge protection systems in accordance with the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 2 R LCF 280 V/25 kA is used in the single-phase mains network. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (chang
Short specification: Class I arrester for LPL I with 25 kA suitable for 230/400 V single-phase TN mains systems. Protection level < 1.6 kV. With remote alert Type: Weidmüller VPU I 2 R LCF 280 V/25 kA Order no. 1351620000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-22
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.73 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m