Article image 1351420000

Weidmueller 1351420000

VPU II 3 PV 1200V DC

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Delivery status: This article will no longer be available in the future.
Available until: 2020-05-01
Type: VPU II 3 PV 1200V DC
Order No.: 1351420000
Version: Surge voltage arrester, Low voltage, 1200 V, without telecomm. contact
GTIN (EAN): 4050118158670
Qty.: 1 pc(s).
Width: 53.4 mm
Width (inches): 2.102 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 402 g
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 3TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Conditions and requirements: EN 50539-11
Discharge current In (8/20 µs): 20 kA
Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE: 1,200 V DC
PV system voltage, max. Ucpv: 1,200 V
Protection level Up mode (+/- , -/PE , +/PE): ≤ 4.4 kV
Requirements class: Type II
Short-circuit curent ISCPV: 200 A
Standards: EN 50539-11
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pole surge voltage arrestor according to the requirements of Class II acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection in applications acc. to IEC 50539-12 in unearthed PV systems. The use of a high-performance varistor consisting of V0 material meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 1200 VDC In/max (8/20 µs): 20/40 kA, protection level < 4.4 kV, type: Weidmüller VPU II 3 PV 1200 V/40 kA, Order No. 1351420000 or equivalent
Short specification: Class II arrester with In/Imax: 20/40 kA suitable for unearthed PV systems. Protection level < 4.4 kV. Type: Weidmüller VPU II 3 PV 1200 V/40 kA Order no. 1351420000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Delivery status: This article will no longer be available in the future.
Available until: 2020-05-01
Type: VPU II 3 PV 1200V DC
Order No.: 1351420000
Version: Surge voltage arrester, Low voltage, 1200 V, without telecomm. contact
GTIN (EAN): 4050118158670
Qty.: 1 pc(s).
Width: 53.4 mm
Width (inches): 2.102 inch
Height: 94 mm
Height (inches): 3.701 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 402 g
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Colour: black, orange
Design: Installation housing; 3TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: without telecomm. contact
Pollution severity: 2
Surge voltage category: III
Conditions and requirements: EN 50539-11
Discharge current In (8/20 µs): 20 kA
Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE: 1,200 V DC
PV system voltage, max. Ucpv: 1,200 V
Protection level Up mode (+/- , -/PE , +/PE): ≤ 4.4 kV
Requirements class: Type II
Short-circuit curent ISCPV: 200 A
Standards: EN 50539-11
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pole surge voltage arrestor according to the requirements of Class II acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection in applications acc. to IEC 50539-12 in unearthed PV systems. The use of a high-performance varistor consisting of V0 material meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. Rated voltage: 1200 VDC In/max (8/20 µs): 20/40 kA, protection level < 4.4 kV, type: Weidmüller VPU II 3 PV 1200 V/40 kA, Order No. 1351420000 or equivalent
Short specification: Class II arrester with In/Imax: 20/40 kA suitable for unearthed PV systems. Protection level < 4.4 kV. Type: Weidmüller VPU II 3 PV 1200 V/40 kA Order no. 1351420000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.402 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m