Article image 1351370000

Weidmueller 1351370000

VPU II 2 R PV 600V DC

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VPU II 2 R PV 600V DC
Order No.: 1351370000
Version: Surge voltage arrester, Low voltage, 600 V, with remote contact
GTIN (EAN): 4050118158717
Qty.: 1 pc(s).
Width: 35.6 mm
Width (inches): 1.402 inch
Height: 106 mm
Height (inches): 4.173 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 0.304 g
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Connection type: PUSH IN
Stripping length: 8 mm
Cross-section for connected wire, solid core, min.: 0.14 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black, orange
Design: Installation housing; 2TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: with remote contact
Pollution severity: 2
Surge voltage category: III
Conditions and requirements: EN 50539-11
Discharge current In (8/20 µs): 12.5 kA
Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE: 600 V DC
PV system voltage, max. Ucpv: 600 V
Protection level Up mode (+/-): ≤ 4.4 kV
Protection level Up mode (-/PE): ≤ 2.2 kV
Protection level Up mode(+/PE): ≤ 2.2 kV
Requirements class: Type II
Short-circuit curent ISCPV: 200 A
Standards: EN 50539-11
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pole surge voltage arrestor according to the requirements of Class II acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection and is used in applications according to IEC 50539-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (CO contact). Rated voltage: 600 VDC In/max (8/20 µs): 20/40 kA, protection level < 2.2 kV, telecommunication output: contact: 250 V/0.5 A 48 VDC/0.1 A, type: Weidmüller VPU II 2 R PV 600 V/40 kA, Order No. 1351370000 or equivalent
Short specification: Class II arrester with In/Imax: 20/40 kA suitable for PV systems. Protection level < 2.2 kV. With remote alert Type: Weidmüller VPU II 2 R PV 600 V/40 kA Order no. 1351370000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VPU II 2 R PV 600V DC
Order No.: 1351370000
Version: Surge voltage arrester, Low voltage, 600 V, with remote contact
GTIN (EAN): 4050118158717
Qty.: 1 pc(s).
Width: 35.6 mm
Width (inches): 1.402 inch
Height: 106 mm
Height (inches): 4.173 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Mounting dimension - height: 75 mm
Net weight: 0.304 g
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
Connection type: PUSH IN
Stripping length: 8 mm
Cross-section for connected wire, solid core, min.: 0.14 mm²
Cross-section for connected wire, solid core, max.: 1.5 mm²
Colour: black, orange
Design: Installation housing; 2TE, Insta IP 20
Optical function display: green = OK; red = arrester is defective - replace
Protection degree: IP20
Rail: TS 35
UL 94 flammability rating: V-0
Version: with remote contact
Pollution severity: 2
Surge voltage category: III
Conditions and requirements: EN 50539-11
Discharge current In (8/20 µs): 12.5 kA
Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE: 600 V DC
PV system voltage, max. Ucpv: 600 V
Protection level Up mode (+/-): ≤ 4.4 kV
Protection level Up mode (-/PE): ≤ 2.2 kV
Protection level Up mode(+/PE): ≤ 2.2 kV
Requirements class: Type II
Short-circuit curent ISCPV: 200 A
Standards: EN 50539-11
Type of connection: Screw connection
Stripping length, rated connection: 15 mm
Tightening torque, min.: 2 Nm
Tightening torque, max.: 3 Nm
Clamping range, rated connection: 16 mm²
Clamping range, min.: 1.5 mm²
Clamping range, max.: 35 mm²
Wire cross-section, solid, min.: 1.5 mm²
Wire cross-section, solid, max.: 16 mm²
Wire connection cross-section, finely stranded, min.: 1.5 mm²
Wire connection cross section, finely stranded, max.: 25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 50 mm²
Connection cross-section, stranded, min.: 1.5 mm²
Connection cross-section, stranded, max.: 50 mm²
Long specification: Multi-pole surge voltage arrestor according to the requirements of Class II acc. to IEC 50539-11. Consisting of V0 material, the arrestor serves as overvoltage protection and is used in applications according to IEC 50539-12. The use of a high-performance varistor meets the inspection requirements for Class II surge protection systems on the basis of the standards. The arrestor is installed in the vicinity of the equipment that needs protection, in a commercially available installation/electrical distribution enclosure. With thermal separation device on the varistor. If protection is no longer available, the colour in the display window changes from green to red. The functional state is also displayed by a voltage-free signalling contact (CO contact). Rated voltage: 600 VDC In/max (8/20 µs): 20/40 kA, protection level < 2.2 kV, telecommunication output: contact: 250 V/0.5 A 48 VDC/0.1 A, type: Weidmüller VPU II 2 R PV 600 V/40 kA, Order No. 1351370000 or equivalent
Short specification: Class II arrester with In/Imax: 20/40 kA suitable for PV systems. Protection level < 2.2 kV. With remote alert Type: Weidmüller VPU II 2 R PV 600 V/40 kA Order no. 1351370000 or equivalent
ETIM 6.0: EC000941
ETIM 7.0: EC000941
eClass 9.0: 27-13-08-05
eClass 9.1: 27-13-08-05
eClass 10.0: 27-13-08-05
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.304 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m