1351350000
VPU I 1 LCF 280V/35KA
Surge voltage arrester, Low voltage, without telecomm. contact, Leakage-current-free, Single-phase
| Type: | VPU I 1 LCF 280V/35KA |
| Order No.: | 1351350000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, Leakage-current-free, Single-phase |
| GTIN (EAN): | 4050118158724 |
| Qty.: | 1 pc(s). |
| Width: | 71.2 mm |
| Width (inches): | 2.803 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 520 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black |
| Design: | Installation housing; 4TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Power distribution |
| Suitable for: | Count-in installation (leakage current free) |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact, Leakage-current-free |
| Pollution severity: | 2 |
| Surge voltage category: | IV |
| Rated voltage (AC): | 230 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 280 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 25 kA |
| Discharge current Imax (8/20µs) wire-PE: | 100 kA |
| Lightning test current Iimp (10/350 µs) (L-PE): | 35 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | No Fuse neccessary ≤315 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type I, Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 1 µA |
| Temporary surge voltage (over-voltage) - TOV: | 440 V |
| Number of poles: | 1 |
| Rated load current IL: | 100 A |
| Requirements category acc. to IEC 61643-11: | Type I, Type II |
| Requirements class, acc. to EN 61643-11: | T1, T2 |
| Response time: | ≤ 100 ns |
| Signalling contact: | No |
| Suitable for: | Count-in installation (leakage current free) |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 4 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 2.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 2.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 2.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Single-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (acc. to IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a non-blow-out sparkover gap, in combination with a high-power varistor, satisfies the inspection requirements for Class I surge protection systems in accordance with the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 1 R LCF 280 V/35 kA is earthed, in combination with three or four identical arrestors, between the outer conductors ( L1, L2, L3 and / or the neutral conduct |
| Short specification: | Class I arrester for LPL 1 with 35 kA suitable for 230/400 V mains systems. Protection level < 2.5 kV. Type: Weidmüller VPU I 1 LCF 280 V/35 kA Order no. 1351350000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-22 |
| ROHS: | Conform |
| Type: | VPU I 1 LCF 280V/35KA |
| Order No.: | 1351350000 |
| Version: | Surge voltage arrester, Low voltage, without telecomm. contact, Leakage-current-free, Single-phase |
| GTIN (EAN): | 4050118158724 |
| Qty.: | 1 pc(s). |
| Width: | 71.2 mm |
| Width (inches): | 2.803 inch |
| Height: | 94 mm |
| Height (inches): | 3.701 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Mounting dimension - height: | 75 mm |
| Net weight: | 520 g |
| Humidity: | 5 - 95% rel. humidity |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| Colour: | black |
| Design: | Installation housing; 4TE, Insta IP 20 |
| Optical function display: | green = OK; red = arrester is defective - replace |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Power distribution |
| Suitable for: | Count-in installation (leakage current free) |
| UL 94 flammability rating: | V-0 |
| Version: | without telecomm. contact, Leakage-current-free |
| Pollution severity: | 2 |
| Surge voltage category: | IV |
| Rated voltage (AC): | 230 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 280 V |
| Low voltage network: | Single-phase |
| Discharge current In (8/20µs) wire-PE: | 25 kA |
| Discharge current Imax (8/20µs) wire-PE: | 100 kA |
| Lightning test current Iimp (10/350 µs) (L-PE): | 35 kA |
| Frequency range, max.: | 60 Hz |
| Frequency range, min.: | 50 Hz |
| Fuse: | No Fuse neccessary ≤315 A gG |
| Short-circuit current rating ISCCR: | 25 kA |
| Follow-on current extinguishing capability Ifi: | Not available due for technical reasons |
| Standards: | IEC61643-11, EN61643-11 |
| Energy coordination (≤10 m): | Type I, Type II, Type III |
| Protection level Up at IN (L/N-PE): | ≤ 1.8 kV |
| Leakage current at Un: | 1 µA |
| Temporary surge voltage (over-voltage) - TOV: | 440 V |
| Number of poles: | 1 |
| Rated load current IL: | 100 A |
| Requirements category acc. to IEC 61643-11: | Type I, Type II |
| Requirements class, acc. to EN 61643-11: | T1, T2 |
| Response time: | ≤ 100 ns |
| Signalling contact: | No |
| Suitable for: | Count-in installation (leakage current free) |
| Type of connection: | Screw connection |
| Stripping length, rated connection: | 15 mm |
| Tightening torque, min.: | 2 Nm |
| Tightening torque, max.: | 3 Nm |
| Clamping range, rated connection: | 16 mm² |
| Clamping range, min.: | 4 mm² |
| Clamping range, max.: | 35 mm² |
| Wire cross-section, solid, min.: | 2.5 mm² |
| Wire cross-section, solid, max.: | 16 mm² |
| Wire connection cross-section, finely stranded, min.: | 2.5 mm² |
| Wire connection cross section, finely stranded, max.: | 25 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 2.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 50 mm² |
| Connection cross-section, stranded, min.: | 2.5 mm² |
| Connection cross-section, stranded, max.: | 50 mm² |
| Long specification: | Single-pin lightning arrestor according to the requirements of Class I in accordance with IEC 61643-11, EN61643-11:2013. On interface transition from 0 to 1 (acc. to IEC 1312-1), the arrestor, made from V0 material, serves as lightning protection providing equipotential bonding and is used in applications in accordance with IEC 61643-12. Surge protection is used in the TN, TT and IT mains system types in combination with several lightning protectors. The use of a non-blow-out sparkover gap, in combination with a high-power varistor, satisfies the inspection requirements for Class I surge protection systems in accordance with the VDEW (Association of German Power Stations) directive. The arrestor is installed in the vicinity of the power supply for the equipment that needs protection, in a standard installation/electrical distribution enclosure. The VPU I 1 R LCF 280 V/35 kA is earthed, in combination with three or four identical arrestors, between the outer conductors ( L1, L2, L3 and / or the neutral conduct |
| Short specification: | Class I arrester for LPL 1 with 35 kA suitable for 230/400 V mains systems. Protection level < 2.5 kV. Type: Weidmüller VPU I 1 LCF 280 V/35 kA Order no. 1351350000 or equivalent |
| ETIM 6.0: | EC000941 |
| ETIM 7.0: | EC000941 |
| eClass 9.0: | 27-13-08-05 |
| eClass 9.1: | 27-13-08-05 |
| eClass 10.0: | 27-13-08-05 |
| UNSPSC: | 30-21-19-22 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |