1161180000
VSPC 4SL 24VAC EX
| Type: | VSPC 4SL 24VAC EX |
| Order No.: | 1161180000 |
| Version: | Surge protection for instrumentation and control, 24 V, 34 V, 300 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248950119 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 90 mm |
| Height (inches): | 3.543 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 53 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 43 |
| MTTF: | 2,665 Years |
| PFH in 1*10-9 per hour: | 8.9 |
| SFF: | 79.3 % |
| SIL in compliance with IEC 61508: | 2 |
| REACH SVHC: | Lead 7439-92-1 |
| ATEX - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| ATEX - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Certificate No. (ATEX): | KEMA10ATEX0148X |
| IECEx - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| IECEx - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Input power, max. PI: | 3 W |
| Input voltage, max. Ui: | 38 V |
| Internal capacity, max. CI: | < 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Temperature class T4/135°C (-40°C ... +85°C) li: | 350 mA |
| Temperature class T5/100°C (-40 ° C ... +75°C) li: | 250 mA |
| Temperature class T6/85 °C (-40 °C ... +60°C) li: | 250 mA |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 38 V |
| Internal capacity, max. CI: | 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | Light Blue |
| Design: | Terminal, miscellaneous |
| Optical function display: | No |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | without warning function / function indicator |
| protected binary signals: | 4 |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 34 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 28 V |
| Max. continuous voltage, Uc (DC): | 38 V |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 10 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 2.5 kA |
| Standards: | IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Protection level UP (typ.): | 250 V |
| Protection level on output side Wire-PE 1kV/µs, typically: | 60 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 110 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 80 V |
| Protection level, UP GND - PE: | 60 V |
| Protection level, UP wire - PE: | 60 V |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Input voltage, max. Ui: | 38 V |
| Number of poles: | 2 |
| Overload - failure mode: | Modus 2 |
| Protection level, UP wire - wire: | 80 V |
| Pulse-reset capacity: | ≤ 30 ms |
| Rated current IN: | 300 mA |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Signal transmission properties (-3 dB): | 2.7 MHz |
| Signalling contact: | No |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 5 kA 8/20 μs |
| Surge current-carrying capacity C3: | 100 A 10/1000 μs |
| Surge current-carrying capacity D1: | 2.5 kA 10/350 μs |
| Volume resistance: | 4.7 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Long specification: | Surge protection plug for use in connection with the base element VSPC BASE 4SL FG for four floating-ground driven, intrinsically safe signal cables EX ia. Two-stage protection consisting of coarse and fine protection between all signal cables as well as coarse common mode voltage protection to signal ground/earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug. |
| Short specification: | Surge protection plug for base element VSPC BASE 4SL FG, transverse voltage coarse and fine protection for four floating-ground powered, intrinsically safe signal cables EX ia, coarse common mode voltage protection to earth. Version: 24 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSPC 4SL 24VAC EX |
| Order No.: | 1161180000 |
| Version: | Surge protection for instrumentation and control, 24 V, 34 V, 300 mA, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| GTIN (EAN): | 4032248950119 |
| Qty.: | 1 pc(s). |
| Width: | 17.8 mm |
| Width (inches): | 0.701 inch |
| Height: | 90 mm |
| Height (inches): | 3.543 inch |
| Depth: | 69 mm |
| Depth (inches): | 2.717 inch |
| Net weight: | 53 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 43 |
| MTTF: | 2,665 Years |
| PFH in 1*10-9 per hour: | 8.9 |
| SFF: | 79.3 % |
| SIL in compliance with IEC 61508: | 2 |
| REACH SVHC: | Lead 7439-92-1 |
| ATEX - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| ATEX - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Certificate No. (ATEX): | KEMA10ATEX0148X |
| IECEx - dust labelling: | II 1 D Ex ia IIIC T135 °C …T85 °C Da |
| IECEx - gas labelling: | II 1 G Ex ia IIC T4… T6 Ga |
| Input power, max. PI: | 3 W |
| Input voltage, max. Ui: | 38 V |
| Internal capacity, max. CI: | < 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Temperature class T4/135°C (-40°C ... +85°C) li: | 350 mA |
| Temperature class T5/100°C (-40 ° C ... +75°C) li: | 250 mA |
| Temperature class T6/85 °C (-40 °C ... +60°C) li: | 250 mA |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input voltage, max. Ui: | 38 V |
| Internal capacity, max. CI: | 4 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | Light Blue |
| Design: | Terminal, miscellaneous |
| Optical function display: | No |
| Protection degree: | IP20 |
| Segment: | Measurement - Monitoring - Setting |
| UL 94 flammability rating: | V-0 |
| Version: | without warning function / function indicator |
| protected binary signals: | 4 |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 34 V |
| Voltage type: | AC |
| Max. continuous voltage, Uc (AC): | 28 V |
| Max. continuous voltage, Uc (DC): | 38 V |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Discharge current In (8/20µs) wire-wire: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-wire: | 10 kA |
| Lightning test current, Iimp (10/350 µs) GND-PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 2.5 kA |
| Lightning test current, Iimp (10/350 µs) wire-wire: | 2.5 kA |
| Standards: | IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006 |
| Protection level UP (typ.): | 250 V |
| Protection level on output side Wire-PE 1kV/µs, typically: | 60 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 110 V |
| Protection level on output side Wire-wire 8/20 µs, typically: | 80 V |
| Protection level, UP GND - PE: | 60 V |
| Protection level, UP wire - PE: | 60 V |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Input voltage, max. Ui: | 38 V |
| Number of poles: | 2 |
| Overload - failure mode: | Modus 2 |
| Protection level, UP wire - wire: | 80 V |
| Pulse-reset capacity: | ≤ 30 ms |
| Rated current IN: | 300 mA |
| Requirements category acc. to IEC 61643-21: | C1, C2, C3, D1 |
| Signal transmission properties (-3 dB): | 2.7 MHz |
| Signalling contact: | No |
| Surge current-carrying capacity C1: | < 1 kA 8/20 μs |
| Surge current-carrying capacity C2: | 5 kA 8/20 μs |
| Surge current-carrying capacity C3: | 100 A 10/1000 μs |
| Surge current-carrying capacity D1: | 2.5 kA 10/350 μs |
| Volume resistance: | 4.7 Ω |
| Type of connection: | Pluggable in VSPC BASE |
| Long specification: | Surge protection plug for use in connection with the base element VSPC BASE 4SL FG for four floating-ground driven, intrinsically safe signal cables EX ia. Two-stage protection consisting of coarse and fine protection between all signal cables as well as coarse common mode voltage protection to signal ground/earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug. |
| Short specification: | Surge protection plug for base element VSPC BASE 4SL FG, transverse voltage coarse and fine protection for four floating-ground powered, intrinsically safe signal cables EX ia, coarse common mode voltage protection to earth. Version: 24 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.053 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |