Article image 1123370000

Weidmueller 1123370000

TRZ 24VDC 1CO EMPTY

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: TRZ 24VDC 1CO EMPTY
Order No.: 1123370000
Version: TERMSERIES, Relay bases, Number of contacts: 1, CO contact, Rated control voltage: 24 V DC ±20 %, Continuous current: 10 A, Tension-clamp connection
GTIN (EAN): 4032248905324
Qty.: 10 pc(s).
Width: 6.4 mm
Width (inches): 0.252 inch
Height: 90.5 mm
Height (inches): 3.563 inch
Depth: 87.8 mm
Depth (inches): 3.457 inch
Net weight: 25.7 g
Operating temperature, max.: 60 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E223759
Ambient temperature (operational), max.: 60 °C
Connection cross-section AWG, min.: AWG 26
Connection cross-section AWG, max.: AWG 14
Type of conductor: rigid copper conductor, flexible copper conductor
Pollution severity level: 2
Altitude: ≤ 2000 m, above sea level
Rated control voltage: 24 V DC ±20 %
Status indicator: Green LED
Protective circuit: Free-wheeling diode, Reverse polarity protection
Coil voltage of the replacement relay deviating from the rated control voltage: No
Coil voltage of the replacement relay: 24 V DC
Rated switching voltage: 250 V AC
Continuous current: 10 A
Contact type: 1 CO contact
Rail: TS 35
Colour: black
UL 94 flammability rating: V-0
Rated voltage: 300 V
Pollution severity: 2
Surge voltage category: III
Impulse withstand voltage: 6 kV (1.2/50 µs)
Protection degree: IP20
Standards: DIN EN 50178
Certificate No. (cURus): E223759
Wire connection method: Tension-clamp connection
Stripping length, rated connection: 8 mm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.14 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.14 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.14 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire cross-section, finely stranded, min. (AWG): AWG 26
Wire cross-section, finely stranded, max. (AWG): AWG 14
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.14 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.14 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 1.5 mm²
Twin wire-end ferrules, min.: 0.5 mm²
Twin wire-end ferrules, max.: 1 mm²
Blade size: 0.6 x 3.5 mm
Gauge to IEC 60947-1: A1, B1
ETIM 6.0: EC001456
ETIM 7.0: EC001456
eClass 9.0: 27-37-16-03
eClass 9.1: 27-37-16-03
eClass 10.0: 27-37-16-03
ROHS: Conform
Type: TRZ 24VDC 1CO EMPTY
Order No.: 1123370000
Version: TERMSERIES, Relay bases, Number of contacts: 1, CO contact, Rated control voltage: 24 V DC ±20 %, Continuous current: 10 A, Tension-clamp connection
GTIN (EAN): 4032248905324
Qty.: 10 pc(s).
Width: 6.4 mm
Width (inches): 0.252 inch
Height: 90.5 mm
Height (inches): 3.563 inch
Depth: 87.8 mm
Depth (inches): 3.457 inch
Net weight: 25.7 g
Operating temperature, max.: 60 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 85 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...60 °C
Storage temperature: -40 °C...85 °C
REACH SVHC: Lead 7439-92-1
Certificate No. (cURus): E223759
Ambient temperature (operational), max.: 60 °C
Connection cross-section AWG, min.: AWG 26
Connection cross-section AWG, max.: AWG 14
Type of conductor: rigid copper conductor, flexible copper conductor
Pollution severity level: 2
Altitude: ≤ 2000 m, above sea level
Rated control voltage: 24 V DC ±20 %
Status indicator: Green LED
Protective circuit: Free-wheeling diode, Reverse polarity protection
Coil voltage of the replacement relay deviating from the rated control voltage: No
Coil voltage of the replacement relay: 24 V DC
Rated switching voltage: 250 V AC
Continuous current: 10 A
Contact type: 1 CO contact
Rail: TS 35
Colour: black
UL 94 flammability rating: V-0
Rated voltage: 300 V
Pollution severity: 2
Surge voltage category: III
Impulse withstand voltage: 6 kV (1.2/50 µs)
Protection degree: IP20
Standards: DIN EN 50178
Certificate No. (cURus): E223759
Wire connection method: Tension-clamp connection
Stripping length, rated connection: 8 mm
Clamping range, rated connection: 1.5 mm²
Clamping range, min.: 0.14 mm²
Clamping range, max.: 2.5 mm²
Wire connection cross section AWG, min.: AWG 26
Wire connection cross section AWG, max.: AWG 14
Wire cross-section, solid, min.: 0.14 mm²
Wire cross-section, solid, max.: 2.5 mm²
Wire connection cross-section, finely stranded, min.: 0.14 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Wire cross-section, finely stranded, min. (AWG): AWG 26
Wire cross-section, finely stranded, max. (AWG): AWG 14
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: 0.14 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.14 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 1.5 mm²
Twin wire-end ferrules, min.: 0.5 mm²
Twin wire-end ferrules, max.: 1 mm²
Blade size: 0.6 x 3.5 mm
Gauge to IEC 60947-1: A1, B1
ETIM 6.0: EC001456
ETIM 7.0: EC001456
eClass 9.0: 27-37-16-03
eClass 9.1: 27-37-16-03
eClass 10.0: 27-37-16-03
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.026 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m