Article image 1070470000

Weidmueller 1070470000

VSPC BASE 1CL PW FG EX

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VSPC BASE 1CL PW FG EX
Order No.: 1070470000
Version: Surge protection, Flange-mounted housing, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248826384
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 75 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Certificate No. (ATEX): KEMA10ATEX0148X
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Internal inductance, max. LI: 0 µH
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 350 mA
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal, miscellaneous
Optical function display: No
Protection degree: IP20
Rail: TS 35, TS 35 x 7.5
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Flange-mounted housing
Pollution severity: 2
Surge voltage category: III
Voltage type: AC/DC
Standards: IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Leakage current at Un: 0 µA
Dielectric strength at FG against PE: ≥ 500 V
Signalling contact: No
Type of connection: Screw connection
Stripping length, rated connection: 7 mm
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 4 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 2.5 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 2.5 mm²
Blade size: 0.6 x 3.5 mm
Long specification: Base unit for floating-ground powered paired cables and 24 V power supplies. With the installation of the base element a contact is established between mounting rail and the integrated sparkover gap. Through this sparkover gap, a high impedance connection between the ground of the protective switch in the protective plug and the earth potential is made. Suitable for ATEX applications. Mechanical coding of the base element to the protected plug according to switching type and rated voltage. The base unit is coded itself by the first insertion of a protected plug. Optical identification of the protected plug based on the type of protected switching and the voltage level. Possible to mark all terminals
Short specification: Base element to receive a protected plug for an floating-ground powered paired cable and 24 V power supply with indirect earthing. Suitable for ATEX applications.
ETIM 6.0: EC000472
ETIM 7.0: EC000472
eClass 9.0: 27-13-08-03
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-03
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSPC BASE 1CL PW FG EX
Order No.: 1070470000
Version: Surge protection, Flange-mounted housing, IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248826384
Qty.: 1 pc(s).
Width: 17.8 mm
Width (inches): 0.701 inch
Height: 90 mm
Height (inches): 3.543 inch
Depth: 69 mm
Depth (inches): 2.717 inch
Net weight: 75 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Certificate No. (ATEX): KEMA10ATEX0148X
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Internal inductance, max. LI: 0 µH
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 350 mA
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal, miscellaneous
Optical function display: No
Protection degree: IP20
Rail: TS 35, TS 35 x 7.5
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Flange-mounted housing
Pollution severity: 2
Surge voltage category: III
Voltage type: AC/DC
Standards: IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Leakage current at Un: 0 µA
Dielectric strength at FG against PE: ≥ 500 V
Signalling contact: No
Type of connection: Screw connection
Stripping length, rated connection: 7 mm
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 4 mm²
Wire connection cross section, finely stranded, max.: 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 2.5 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 2.5 mm²
Blade size: 0.6 x 3.5 mm
Long specification: Base unit for floating-ground powered paired cables and 24 V power supplies. With the installation of the base element a contact is established between mounting rail and the integrated sparkover gap. Through this sparkover gap, a high impedance connection between the ground of the protective switch in the protective plug and the earth potential is made. Suitable for ATEX applications. Mechanical coding of the base element to the protected plug according to switching type and rated voltage. The base unit is coded itself by the first insertion of a protected plug. Optical identification of the protected plug based on the type of protected switching and the voltage level. Possible to mark all terminals
Short specification: Base element to receive a protected plug for an floating-ground powered paired cable and 24 V power supply with indirect earthing. Suitable for ATEX applications.
ETIM 6.0: EC000472
ETIM 7.0: EC000472
eClass 9.0: 27-13-08-03
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-03
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.078 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m