1064950000
VSSC6 TRLDTAZ 24VAC/DC
| Type: | VSSC6 TRLDTAZ 24VAC/DC |
| Order No.: | 1064950000 |
| Version: | Surge protection for instrumentation and control, 24 V, 34 V, 12 A, IEC 61643-21 |
| GTIN (EAN): | 4032248830190 |
| Qty.: | 10 pc(s). |
| Width: | 6.2 mm |
| Width (inches): | 0.244 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 46 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 43 |
| MTTF: | 2,655 years |
| PFH in 1*10-9 per hour: | 0.9 |
| SFF: | 97.91 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 500 mA |
| Input voltage, max. Ui: | 42 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | black |
| Design: | Terminal |
| Isolating function: | Yes |
| Optical function display: | Yes |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| Testing option: | Functional screw with test plug receptacle, connections 1, 2, 4, 5 |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 34 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 30 V |
| Max. continuous voltage, Uc (DC): | 42 V |
| Discharge current, max. (8/20 µs): | 0.4 kA |
| Discharge current In (8/20µs) wire-PE: | 0,1 kA |
| Discharge current Imax (8/20µs) wire-PE: | 0.2 kA |
| Standards: | IEC 61643-21 |
| Protection level UP (typ.): | ≤ 100 V |
| Capacitance: | 0.8 nF |
| Number of poles: | 1 |
| Overload - failure mode: | Mode 1 |
| Rated current IN: | 12 A |
| Requirements category acc. to IEC 61643-21: | C3 |
| Surge current-carrying capacity C3: | 15 A |
| Volume resistance: | < 0.1 Ω |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Feed-through terminal, 6.2 mm wide with suppressor diodes between the two signal lines and the mounting rail potential, TS 35 contact base. Each signal path can be opened using an isolator. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Feed-through terminal with suppressor diodes (TAZ) between two signal lines and mounting rail potential.Each signal path can be opened using an isolator. TS 35 contact base. Version: 24 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-18-11 |
| ROHS: | Conform |
| Type: | VSSC6 TRLDTAZ 24VAC/DC |
| Order No.: | 1064950000 |
| Version: | Surge protection for instrumentation and control, 24 V, 34 V, 12 A, IEC 61643-21 |
| GTIN (EAN): | 4032248830190 |
| Qty.: | 10 pc(s). |
| Width: | 6.2 mm |
| Width (inches): | 0.244 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 46 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 43 |
| MTTF: | 2,655 years |
| PFH in 1*10-9 per hour: | 0.9 |
| SFF: | 97.91 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 500 mA |
| Input voltage, max. Ui: | 42 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | black |
| Design: | Terminal |
| Isolating function: | Yes |
| Optical function display: | Yes |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| Testing option: | Functional screw with test plug receptacle, connections 1, 2, 4, 5 |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (AC): | 24 V |
| Rated voltage (DC): | 34 V |
| Voltage type: | AC/DC |
| Max. continuous voltage, Uc (AC): | 30 V |
| Max. continuous voltage, Uc (DC): | 42 V |
| Discharge current, max. (8/20 µs): | 0.4 kA |
| Discharge current In (8/20µs) wire-PE: | 0,1 kA |
| Discharge current Imax (8/20µs) wire-PE: | 0.2 kA |
| Standards: | IEC 61643-21 |
| Protection level UP (typ.): | ≤ 100 V |
| Capacitance: | 0.8 nF |
| Number of poles: | 1 |
| Overload - failure mode: | Mode 1 |
| Rated current IN: | 12 A |
| Requirements category acc. to IEC 61643-21: | C3 |
| Surge current-carrying capacity C3: | 15 A |
| Volume resistance: | < 0.1 Ω |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Feed-through terminal, 6.2 mm wide with suppressor diodes between the two signal lines and the mounting rail potential, TS 35 contact base. Each signal path can be opened using an isolator. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Feed-through terminal with suppressor diodes (TAZ) between two signal lines and mounting rail potential.Each signal path can be opened using an isolator. TS 35 contact base. Version: 24 V AC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-18-11 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.046 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |