1064490000
VSSC6TRSLFGLD12VDC0.5A
| Type: | VSSC6TRSLFGLD12VDC0.5A |
| Order No.: | 1064490000 |
| Version: | Surge protection for instrumentation and control, 12 V, 500 mA, IEC 61643-21 |
| GTIN (EAN): | 4032248829828 |
| Qty.: | 10 pc(s). |
| Width: | 6.2 mm |
| Width (inches): | 0.244 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 44.4 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 54 |
| MTTF: | 2,114 years |
| PFH in 1*10-9 per hour: | 1.8 |
| SFF: | 96.67 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 500 mA |
| Input voltage, max. Ui: | 15 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | black |
| Design: | Terminal |
| Isolating function: | Yes |
| Optical function display: | Yes |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| Testing option: | Functional screw with test plug receptacle, connections 1, 2, 4, 5 |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 12 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 15 V |
| Discharge current, max. (8/20 µs): | 10 kA |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Lightning test current Iimp (10/350 µs): | 1 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 10 kA |
| Fuse: | 0.5 A |
| Standards: | IEC 61643-21 |
| Protection level UP (typ.): | ≤ 100 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 30 V |
| Protection level, UP GND - PE: | 1,400 V |
| Leakage current at Un: | 3.2 mA |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Insertion loss: | 776.85 kHz |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Pulse-reset capacity: | ≤ 20 ms |
| Rated current IN: | 500 mA |
| Requirements category acc. to IEC 61643-21: | C2, C3, D1 |
| Signal transmission properties (-3 dB): | 750 KHz |
| Surge current-carrying capacity C2: | 2.5 kA 8/20 µs 5 kV 1.2/50 µs |
| Surge current-carrying capacity C3: | 10 A 10/1000 µs |
| Surge current-carrying capacity D1: | 1 kA 10/350 μs |
| Volume resistance: | 1.8 Ω 10 % |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits with 12 V DC. Each signal path can be opened using an isolator. Signal indication via a green LED.When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits.Each signal path can be opened using an isolator. Signal indication via a green LED. Version: 12V DC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| Type: | VSSC6TRSLFGLD12VDC0.5A |
| Order No.: | 1064490000 |
| Version: | Surge protection for instrumentation and control, 12 V, 500 mA, IEC 61643-21 |
| GTIN (EAN): | 4032248829828 |
| Qty.: | 10 pc(s). |
| Width: | 6.2 mm |
| Width (inches): | 0.244 inch |
| Height: | 88.5 mm |
| Height (inches): | 3.484 inch |
| Depth: | 81 mm |
| Depth (inches): | 3.189 inch |
| Net weight: | 44.4 g |
| Humidity: | 5...96 % |
| Operating temperature, max.: | 70 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...70 °C |
| Storage temperature: | -40 °C...80 °C |
| λges: | 54 |
| MTTF: | 2,114 years |
| PFH in 1*10-9 per hour: | 1.8 |
| SFF: | 96.67 % |
| SIL in compliance with IEC 61508: | 3 |
| REACH SVHC: | Lead 7439-92-1 |
| Certificate No. (UL): | E311081 |
| Gas group C: | IIB |
| Gas group D: | IIA |
| Gas groups A, B: | IIC |
| Input current, max. II: | 500 mA |
| Input voltage, max. Ui: | 15 V |
| Internal capacity, max. CI: | 2 nF |
| Internal inductance, max. LI: | 0 µH |
| Colour: | black |
| Design: | Terminal |
| Isolating function: | Yes |
| Optical function display: | Yes |
| Protection degree: | IP20 |
| Rail: | TS 35 |
| Segment: | Measurement - Monitoring - Setting |
| Testing option: | Functional screw with test plug receptacle, connections 1, 2, 4, 5 |
| UL 94 flammability rating: | V-0 |
| Version: | Surge protection for measurement and control |
| Pollution severity: | 2 |
| Surge voltage category: | III |
| Rated voltage (DC): | 12 V |
| Voltage type: | DC |
| Max. continuous voltage, Uc (DC): | 15 V |
| Discharge current, max. (8/20 µs): | 10 kA |
| Discharge current In (8/20µs) GND-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) GND-PE: | 10 kA |
| Discharge current In (8/20µs) wire-PE: | 2.5 kA |
| Discharge current Imax (8/20µs) wire-PE: | 10 kA |
| Lightning test current Iimp (10/350 µs): | 1 kA |
| Lightning test current, Iimp (10/350 µs) Wire–PE: | 10 kA |
| Fuse: | 0.5 A |
| Standards: | IEC 61643-21 |
| Protection level UP (typ.): | ≤ 100 V |
| Protection level on output side Wire-wire 1 kV/µs, typically: | 30 V |
| Protection level, UP GND - PE: | 1,400 V |
| Leakage current at Un: | 3.2 mA |
| Dielectric strength at FG against PE: | ≥ 500 V |
| Insertion loss: | 776.85 kHz |
| Number of poles: | 1 |
| Overload - failure mode: | Modus 2 |
| Pulse-reset capacity: | ≤ 20 ms |
| Rated current IN: | 500 mA |
| Requirements category acc. to IEC 61643-21: | C2, C3, D1 |
| Signal transmission properties (-3 dB): | 750 KHz |
| Surge current-carrying capacity C2: | 2.5 kA 8/20 µs 5 kV 1.2/50 µs |
| Surge current-carrying capacity C3: | 10 A 10/1000 µs |
| Surge current-carrying capacity D1: | 1 kA 10/350 μs |
| Volume resistance: | 1.8 Ω 10 % |
| Type of connection: | Screw connection |
| Tightening torque, min.: | 0.5 Nm |
| Tightening torque, max.: | 0.8 Nm |
| Clamping range, min.: | 0.5 mm² |
| Clamping range, max.: | 4 mm² |
| Wire cross-section, solid, min.: | 0.5 mm² |
| Wire cross-section, solid, max.: | 6 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), min.: | 0.5 mm² |
| Conductor cross-section, flexible, AEH (DIN 46228-1), max.: | 4 mm² |
| Connection cross-section, stranded, min.: | 0.5 mm² |
| Connection cross-section, stranded, max.: | 4 mm² |
| Long specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits with 12 V DC. Each signal path can be opened using an isolator. Signal indication via a green LED.When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. |
| Short specification: | Surge protection in a one piece, 6.2 mm wide DIN rail module for two binary, potential-free signal circuits.Each signal path can be opened using an isolator. Signal indication via a green LED. Version: 12V DC |
| ETIM 6.0: | EC000943 |
| ETIM 7.0: | EC000943 |
| eClass 9.0: | 27-13-08-07 |
| eClass 9.1: | 27-13-08-07 |
| eClass 10.0: | 27-13-08-07 |
| UNSPSC: | 30-21-19-21 |
| ROHS: | Conform |
| ECCN: | |
| Country of Origin: | |
| EAN: | |
| Weight: | 0.048 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |