Type: VSSC4 GDT55VUC 20kA EX
Order No.: 1064040000
Version: Surge protection for instrumentation and control, 55 V, 80 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248829453
Qty.: 1 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 36.4 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 10
MTTF: 11,416 years
PFH in 1*10-9 per hour: 0
SFF: 100 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 0.75 W
Input voltage, max. Ui: 55 V
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +120 °C) li: 300 mA
Temperature class T5/100°C (-40 ° C ... +85 °C) li: 300 mA
Temperature class T6/85 °C (-40 °C ... +70 °C) li: 300 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 300 mA
Input voltage, max. Ui: 55 V
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 55 V
Rated voltage (DC): 80 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 55 V
Max. continuous voltage, Uc (DC): 38 V
Discharge current, max. (8/20 µs): 20 kA
Discharge current In (8/20µs) wire-PE: 5 kA
Discharge current Imax (8/20µs) wire-PE: 20 kA
Lightning test current Iimp (10/350 µs): 2.5 kA
Standards: IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): ≤ 1900 V
Capacitance: 4.65 pF
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 55 V
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 300 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: < 0.1 Ω
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Feed-through terminal, 12.4mm wide with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base.An intrinsically safe signal with max. 0.3A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. Suitable for ATEX applications. Tested to Ex area ignition protection types: Ex ia IIC / Ex iaD
Short specification: Feed-through terminal with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base. Version: 55V UC. Suitable for ATEX applications.
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform
Type: VSSC4 GDT55VUC 20kA EX
Order No.: 1064040000
Version: Surge protection for instrumentation and control, 55 V, 80 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248829453
Qty.: 1 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 36.4 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 10
MTTF: 11,416 years
PFH in 1*10-9 per hour: 0
SFF: 100 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 0.75 W
Input voltage, max. Ui: 55 V
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +120 °C) li: 300 mA
Temperature class T5/100°C (-40 ° C ... +85 °C) li: 300 mA
Temperature class T6/85 °C (-40 °C ... +70 °C) li: 300 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 300 mA
Input voltage, max. Ui: 55 V
Internal capacity, max. CI: 0 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 55 V
Rated voltage (DC): 80 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 55 V
Max. continuous voltage, Uc (DC): 38 V
Discharge current, max. (8/20 µs): 20 kA
Discharge current In (8/20µs) wire-PE: 5 kA
Discharge current Imax (8/20µs) wire-PE: 20 kA
Lightning test current Iimp (10/350 µs): 2.5 kA
Standards: IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): ≤ 1900 V
Capacitance: 4.65 pF
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 55 V
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 20 ms
Rated current IN: 300 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Surge current-carrying capacity C2: 5 kA 8/20 μs
Surge current-carrying capacity C3: 100 A 10/1000 μs
Surge current-carrying capacity D1: 2.5 kA 10/350 μs
Volume resistance: < 0.1 Ω
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Feed-through terminal, 12.4mm wide with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base.An intrinsically safe signal with max. 0.3A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. Suitable for ATEX applications. Tested to Ex area ignition protection types: Ex ia IIC / Ex iaD
Short specification: Feed-through terminal with gas-filled surge voltage arrester between the signal line connection and the mounting rail potential, TS 35 contact base. Version: 55V UC. Suitable for ATEX applications.
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-18-11
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.188 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m