Article image 1063930000

Weidmueller 1063930000

VSSC4 SL FG 24VAC/DC EX

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Type: VSSC4 SL FG 24VAC/DC Ex
Order No.: 1063930000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248829354
Qty.: 1 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 39.6 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 43
MTTF: 2,655 years
PFH in 1*10-9 per hour: 0.9
SFF: 97.91 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 0.75 W
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 1 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +120 °C) li: 300 mA
Temperature class T5/100°C (-40 ° C ... +85 °C) li: 300 mA
Temperature class T6/85 °C (-40 °C ... +70 °C) li: 300 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 300 mA
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 1 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Lightning test current Iimp (10/350 µs): 1 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Standards: IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): 150 V
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 42 V
Insertion loss: 5.24 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 35 ms
Rated current IN: 300 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 3.4 MHz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 10 A 10/1000 µs
Surge current-carrying capacity D1: 1 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 12.4 mm wide DIN rail module for two binary, potential-free signal circuits with 24 V UC. When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. ATEX version. Tested to Ex area ignition protection types: Ex ia IIC / Ex iaD
Short specification: Surge protection in a one piece, 12.4 mm wide DIN rail module for two binary, potential-free signal circuits. Version: 24 V DC ATEX version.
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform
Type: VSSC4 SL FG 24VAC/DC Ex
Order No.: 1063930000
Version: Surge protection for instrumentation and control, 24 V, 34 V, 300 mA, IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
GTIN (EAN): 4032248829354
Qty.: 1 pc(s).
Width: 12.4 mm
Width (inches): 0.488 inch
Height: 76 mm
Height (inches): 2.992 inch
Depth: 58.5 mm
Depth (inches): 2.303 inch
Net weight: 39.6 g
Humidity: 5...96 %
Operating temperature, max.: 70 °C
Operating temperature, min.: -40 °C
Storage temperature, max.: 80 °C
Storage temperature, min.: -40 °C
Operating temperature: -40 °C...70 °C
Storage temperature: -40 °C...80 °C
λges: 43
MTTF: 2,655 years
PFH in 1*10-9 per hour: 0.9
SFF: 97.91 %
SIL in compliance with IEC 61508: 3
REACH SVHC: Lead 7439-92-1
ATEX - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
IECEx - dust labelling: II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling: II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI: 0.75 W
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 1 nF
Internal inductance, max. LI: 0 µH
Temperature class T4/135°C (-40°C ... +120 °C) li: 300 mA
Temperature class T5/100°C (-40 ° C ... +85 °C) li: 300 mA
Temperature class T6/85 °C (-40 °C ... +70 °C) li: 300 mA
Gas group C: IIB
Gas group D: IIA
Gas groups A, B: IIC
Input current, max. II: 300 mA
Input voltage, max. Ui: 42 V
Internal capacity, max. CI: 1 nF
Internal inductance, max. LI: 0 µH
Colour: Light Blue
Design: Terminal
Isolating function: No
Optical function display: No
Protection degree: IP20
Rail: TS 35
Segment: Measurement - Monitoring - Setting
UL 94 flammability rating: V-0
Version: Surge protection for measurement and control
Pollution severity: 2
Surge voltage category: III
Rated voltage (AC): 24 V
Rated voltage (DC): 34 V
Voltage type: AC/DC
Max. continuous voltage, Uc (AC): 30 V
Max. continuous voltage, Uc (DC): 42 V
Discharge current, max. (8/20 µs): 10 kA
Discharge current In (8/20µs) GND-PE: 2.5 kA
Discharge current Imax (8/20µs) GND-PE: 10 kA
Discharge current In (8/20µs) wire-PE: 2.5 kA
Discharge current Imax (8/20µs) wire-PE: 10 kA
Lightning test current Iimp (10/350 µs): 1 kA
Lightning test current, Iimp (10/350 µs) Wire–PE: 0.5 kA
Standards: IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Protection level UP (typ.): 150 V
Dielectric strength at FG against PE: ≥ 500 V
Input voltage, max. Ui: 42 V
Insertion loss: 5.24 MHz
Number of poles: 1
Overload - failure mode: Modus 2
Pulse-reset capacity: ≤ 35 ms
Rated current IN: 300 mA
Requirements category acc. to IEC 61643-21: C2, C3, D1
Signal transmission properties (-3 dB): 3.4 MHz
Surge current-carrying capacity C2: 2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3: 10 A 10/1000 µs
Surge current-carrying capacity D1: 1 kA 10/350 μs
Volume resistance: 1.8 Ω 10 %
Type of connection: Screw connection
Tightening torque, min.: 0.5 Nm
Tightening torque, max.: 0.8 Nm
Clamping range, min.: 0.5 mm²
Clamping range, max.: 4 mm²
Wire cross-section, solid, min.: 0.5 mm²
Wire cross-section, solid, max.: 6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.: 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.: 4 mm²
Connection cross-section, stranded, min.: 0.5 mm²
Connection cross-section, stranded, max.: 4 mm²
Long specification: Surge protection in a one piece, 12.4 mm wide DIN rail module for two binary, potential-free signal circuits with 24 V UC. When the terminal is fitted, there is a simultaneous sparkover gap created to the high-impedance earth between the mounting rail (earth) and the reference potential (ground) of the protective switch. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. ATEX version. Tested to Ex area ignition protection types: Ex ia IIC / Ex iaD
Short specification: Surge protection in a one piece, 12.4 mm wide DIN rail module for two binary, potential-free signal circuits. Version: 24 V DC ATEX version.
ETIM 6.0: EC000943
ETIM 7.0: EC000943
eClass 9.0: 27-13-08-07
eClass 9.1: 27-13-08-07
eClass 10.0: 27-13-08-07
UNSPSC: 30-21-19-21
ROHS: Conform

Logistic parameters

ECCN:
Country of Origin:
EAN:
Weight: 0.058 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m