Phoenix Contact 1045931

PTFIX 2X1,5 YE

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Technical parameters

Number of levels: 1
Number of connections: 2
Potentials: 1
Nominal cross section: 1.5 mm²
Color: yellow
Insulating material: PA
Flammability rating according to UL 94: V0
Rated surge voltage: 6 kV
Degree of pollution: 3
Overvoltage category: III
Insulating material group: I
Maximum power dissipation for nominal condition: 0.56 W
Maximum load current: 21 A (with a 2.5 mm² conductor cross section)
Maximum total current: 21 A
Nominal current IN: 17.5 A
Nominal voltage UN: 450 V
Open side panel: No
Ambient temperature (operation): -60 °C ... 85 °C
Ambient temperature (storage/transport): -25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C)
Permissible humidity (storage/transport): 30 % ... 70 %
Ambient temperature (assembly): -5 °C ... 70 °C
Ambient temperature (actuation): -5 °C ... 70 °C
Shock protection test specification: DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection: guaranteed
Finger protection: guaranteed
Result of surge voltage test: Test passed
Result of power-frequency withstand voltage test: Test passed
Power frequency withstand voltage setpoint: 1.89 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection): Test passed
Result of bending test: Test passed
Bending test rotation speed: 10 rpm
Bending test turns: 135
Bending test conductor cross section/weight: 0.14 mm² / 0.2 kg
Tensile test result: Test passed
Result of tight fit on support: Test passed
Tight fit on carrier: NS 35/NS 15
Setpoint: 1 N
Result of voltage-drop test: Test passed
Result of temperature-rise test: Test passed
Requirement temperature-rise test: Increase in temperature ≤ 45 K
Short circuit stability result: Test passed
Conductor cross section short circuit testing: 1.5 mm²
Short-time current: 0.18 kA
Conductor cross section short circuit testing: 2.5 mm²
Short-time current: 0.3 kA
Result of thermal test: Test passed
Ageing test for screwless modular terminal block temperature cycles: 192
Proof of thermal characteristics (needle flame) effective duration: 30 s
Result of aging test: Test passed
Oscillation, broadband noise test result: Test passed
Test specification, oscillation, broadband noise: DIN EN 50155 (VDE 0115-200):2018-05
Test spectrum: Service life test category 2, bogie-mounted
Test frequency: f1 = 5 Hz to f2 = 250 Hz
ASD level: 6.12 (m/s2)2/Hz
Acceleration: 3.12 g
Test duration per axis: 5 h
Test directions: X-, Y- and Z-axis
Shock test result: Test passed
Test specification, shock test: DIN EN 50155 (VDE 0115-200):2018-05
Shock form: Half-sine
Acceleration: 30g
Shock duration: 18 ms
Number of shocks per direction: 3
Test directions: X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B): 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 125 °C
Static insulating material application in cold: -60 °C
Surface flammability NFPA 130 (ASTM E 162): passed
Specific optical density of smoke NFPA 130 (ASTM E 662): passed
Calorimetric heat release NFPA 130 (ASTM E 1354): 27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C): passed
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
Width: 4.2 mm
Length: 21.6 mm
Height: 17.7 mm
Connection method: Push-in connection
Stripping length: 8 mm ... 10 mm
Connection in acc. with standard: IEC 60998-2-2
Conductor cross section solid min.: 0.14 mm²
Conductor cross section solid max.: 2.5 mm²
Conductor cross section AWG min.: 26
Conductor cross section AWG max.: 14
Conductor cross section flexible min.: 0.14 mm²
Conductor cross section flexible max.: 1.5 mm²
Min. AWG conductor cross section, flexible: 26
Max. AWG conductor cross section, flexible: 14
Conductor cross section flexible, with ferrule without plastic sleeve min.: 0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.: 1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.: 0.14 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.: 1.5 mm²
Connection cross sections directly pluggable: 0.34 mm² 2.5 mm² 26 14
Conductor cross section solid min.: 0.34 mm²
Conductor cross section solid max.: 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min.: 0.34 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.: 1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.: 0.34 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.: 1.5 mm²
Internal cylindrical gage: A1 / B1
Connection in acc. with standard: IEC 60998-2-2
Flammability rating according to UL 94: V0
China RoHS: Environmentally friendly use period: unlimited = EFUP-e
eCl@ss 10.0.1: 27141120
eCl@ss 4.0: 27141120
eCl@ss 4.1: 27141120
eCl@ss 5.0: 27141120
eCl@ss 5.1: 27141120
eCl@ss 6.0: 27141100
eCl@ss 7.0: 27141120
eCl@ss 8.0: 27141120
eCl@ss 9.0: 27141120
ETIM 2.0: EC000897
ETIM 3.0: EC000897
ETIM 4.0: EC000897
ETIM 5.0: EC000897
ETIM 6.0: EC000897
ETIM 7.0: EC000897
UNSPSC 6.01: 30211811
UNSPSC 7.0901: 39121410
UNSPSC 11: 39121410
UNSPSC 12.01: 39121410
UNSPSC 13.2: 39121410
UNSPSC 18.0: 39121410
UNSPSC 19.0: 39121410
UNSPSC 20.0: 39121410
UNSPSC 21.0: 39121410

Logistic parameters

ECCN:
Country of Origin: PL
EAN:
Weight: 0.002 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m