276399
S1SD-1AI-2C
Transmitter Power Supply/Signal Splitter
1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Dual output 0/4 mA ... 20 mA, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminalspa. This signal conditioner provides the galvanic isolation between field circuits and control circuits. The device supplies 2-wire transmitter. At the output the signal is available as two 0/4 mA ... 20 mA signals. The device can be powered via terminals or Power Bus.
| Signal type: | Analog input |
| Operation time: | MTBF: 313 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F) |
| Connection: | Power Bus or terminals 1-, 2+ |
| Rated voltage: | 16.8 ... 31.2 V DC |
| Power dissipation: | 0.8 W |
| Power consumption: | 1.4 W |
| Connection side: | field side |
| Connection: | terminals 5+, 6- |
| Input signal: | 0/4 ... 20 mA |
| Open circuit voltage/short-circuit current: | ≤ 22 V / 35 mA |
| Input resistance: | ≤ 25 Ω |
| Transmission range: | linearity range: -1 ... 110 % |
| Available voltage: | 16 V at 20 mA |
| Connection side: | control side |
| Ripple: | ≤ 10 mV eff |
| Output I: Connection: | terminals 3-, 4+ |
| Output I: Output signal: | 0/4 ... 20 mA, load ≤ 300 Ω |
| Output II: Connection: | terminals 7+, 8- |
| Output II: Output signal: | 0/4 ... 20 mA, load ≤ 300 Ω |
| Accuracy: | max. 0.1 % of full-scale value |
| Influence of ambient temperature: | < 100 ppm/K of full-scale value |
| Frequency range: | 0 ... 100 Hz |
| Rise time/fall time: | ≤ 3.5 ms |
| Output/power supply: | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Input/Other circuits: | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Output I/II: | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Labeling: | space for labeling at the front |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 (industrial locations) |
| Degree of protection: | IEC 60529:2001 |
| Protection against electrical shock: | EN 61010-1:2010 |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Damaging gas: | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection: | IP20 |
| Connection: | screw terminals |
| Core cross-section: | 0.5 ... 2.5 mm2 (20 ... 14 AWG) |
| Mass: | approx. 70 g |
| Dimensions: | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 |
| Mounting: | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Certificate: | DEMKO 16 ATEX 1750X |
| Electromagnetic compatibility: Marking: | II 3G Ex nA IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
| UL approval: | E106378 |
| IECEx approval: | IECEx UL 16.0116X |
| Directive conformity: Approved for: | Ex nA IIC T4 Gc |
| Supplementary information: | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |