Pepperl+Fuchs 254741

LB5004A

RTD Converter

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

The RTD converter accepts 2-, 3-, 4-wire RTD signals (Pt100 .. Pt1000) and slide-wire sensors from the field. Ni100 through Ni1000 can also be connected. 4 channels, Converter for 2-, 3- and 4-wire RTDs (Pt100 .. Pt1000), slide wire sensors etc., Installation in Zone 2 or safe area, Simulation mode for service operations (forcing)pa. Open and short-circuit line faults are detected. The inputs are galvanically isolated from the bus and the power supply.

Technical parameters

Occupied slots: 2
Connection: backplane bus
Rated voltage: 12 V DC , only in connection with the power supplies LB9***
Power dissipation: 0.35 W
Power consumption: 0.35 W
Connection: backplane bus
Interface: manufacturer-specific bus to standard com unit
Number of channels: 4
Suitable field devices: Field device: resistance thermometer
Suitable field devices: Field device [3]: slide-wire sensors
Suitable field devices: Field device [5]: potentiometer
Field device interface: Connection: 2-wire sensor
Field device interface: Connection [2]: 3-wire sensor
Field device interface: Connection [3]: 4-wire sensor
Connection: channel I: resistance/potentiometer input 1 ... 4 channel II: resistance/potentiometer input 5 ... 8 channel III: resistance/potentiometer input 9 ... 12 channel IV: resistance/potentiometer input 13 ... 16
Measurement range: Pt100 (18-390 Ω) (500 Ω incl. line resistance) Pt200 (37-780 Ω) Pt500 (92-1952 Ω) Pt1000 (185-3905 Ω) Ni100 (69-270 Ω) Ni500 (345-1350 Ω) Ni1000 (690-2700 Ω)
Slide-wire sensor: 0 ... 10 kΩ
Measuring current: 200 µA
Smallest span: 50 Ω for 0.1 % accuracy
Linearity error: 0.1 %
Conversion time: max. 500 ms (4 channels) max. 1 s (for 4x 3-wire Pt100)
Busy after download: 5 ... 15 s
Lead resistance: max. 50 Ω per strand
Line fault detection: can be switched on/off for each channel via configuration tool
Field device interface: Short-circuit: < 10 Ω
Field device interface: Open-circuit: > 1 kΩ
Deviation: Influence of ambient temperature: max. 0,1 %/10 K
LED indication: Power LED (P) green: supply Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Coding: optional mechanical coding via front socket
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1
Electromagnetic compatibility: NE 21
Degree of protection: IEC 60529
Environmental test: EN 60068-2-14
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Damaging gas: EN 60068-2-42
Relative humidity: EN 60068-2-56
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Relative humidity: 95 % non-condensing
Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Degree of protection: IP20 when mounted on backplane
Connection: removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Mass: approx. 150 g
Dimensions: 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Certificate: PF 08 CERT 1234 X
Electromagnetic compatibility: Marking: II 3 G Ex nA [ic] IIC T4 Gc
Galvanic isolation: Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010
IECEx approval: BVS 09.0037X
Directive conformity: Approved for: Ex nA [ic] IIC T4 Gc
Marine approval: Lloyd Register: 15/20021
Marine approval: DNV GL Marine: TAA0000034
Marine approval: Bureau Veritas Marine: 22449/B0 BV
System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Logistic parameters

ECCN:
Country of Origin: Deutschland
EAN: 4050143064014
Weight: 0.13 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m