235639
KE5D2-6H/2R-S
Safety Monitor
24 V AC/DC supply, (6) Monitored inputs, DIN rail mountable, Dual output relay contacts, Internal relay monitoringfa
| UL File Number: | E179102 |
| Rated voltage: | 24 V AC/V DC ( for AC, 45 ... 62 Hz ) |
| Rated current: | < 0 . 5 A |
| Power consumption: | < 12 W |
| LED green: | power |
| LED red: | sensor status (one per channel/two per input) |
| LED red/green: | relay : ( 2 ) red , ( 2 ) green |
| Switching state: | LED red flashing: fault signal |
| Input type: | (6) dedicated input devices for 50FY41-.. series |
| Input voltage: | 12 V DC , (2 channel, sink/source) |
| Current: | 5 mA to 5 A (NO contact) |
| Relay: Switching voltage: | 20 ... 230 V AC/DC |
| Relay: Switching current: | See Specifications in manual for details of currents and cycles |
| Relay: Mechanical life: | > 1,000,000 operations |
| Output I: | 2 relay outputs , NO Contact |
| Response time: | 20 ms (switch open to contact open) |
| Time delay before availability: | 3 s |
| Directive conformity: Machinery Directive 2006/42/EC: | EN/ISO 13849-1:2008 / AC : 2009 category 3 PL d |
| Directive conformity: Low Voltage Directive 2006/95/EC: | EN 60664-1:2007 |
| Directive conformity: EMC Directive 2004/108/EC: | EN 61326-1:2006 |
| Standard conformity: Electromagnetic compatibility: | EN 61326-1:2006 EN 61000-6-3:2007+A1:2011 or EN 61000-6-4:2007/A1:2011 |
| Standard conformity: Standards: | EN 61496-1:2008 IEC 61496-2:2006 EN 50178:1998 |
| UL approval: | UL 508 |
| Ambient temperature: | -20 ... 50 °C (-4 ... 122 °F) |
| Degree of protection: | IP20 |
| Connection: | screw connection, max. 2.5 mm2 |
| Mass: | approx. 545 g |
| Mounting: | DIN mounting rail |
| ECCN: | |
| Country of Origin: | SG |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |