Pepperl+Fuchs 217734

KFD2-ER-2.W.LB

Conductivity Switch Amplifier

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

This signal conditioner provides the AC measuring voltage for the level sensing electrodes. 2-channel signal conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ .. 150 kΩ, Relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)pa. Once the measured medium reaches the electrodes, the unit reacts by energizing a form C changeover relay contact. The module is voltage and temperature stabilized and guarantees a defined switching characteristic. It can be used for on/off control or minimum/maximum control. A signal delay feature is available and is adjustable between 0.5 s and 10 s. This module can also monitor the field circuit for lead breakage (LB). LB is indicated by a red LED. This function can be deactivated with DIP switches.

Technical parameters

Signal type: Digital Input
Connection: Power Rail or terminals 14+, 15-
Rated voltage: 20 ... 30 V DC
Rated current: 30 ... 40 mA
Connection side: field side
Connection: terminals 1, 4 (mass), 2, 5 (min), 3, 6 (max)
Control input: min./max. control system: terminals 1, 2, 3; 4, 5. 6 on/off control system: terminals 1, 3; 4, 6
Response sensitivity: 1 ... 150 kΩ , adjustable via potentiometer
Connection side: control side
Connection: terminals 7, 8, 9; 10, 11, 12
Switching power: max. 192 W , 2000 VA
Output: relay
Contact loading: 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Time constant for signal damping: 0.5 s, 2 s, 5 s, 10 s
Input/Output: basic insulation according to EN 50178, rated insulation voltage 253 Veff
Input/power supply: basic insulation according to EN 50178, rated insulation voltage 253 Veff
Output/power supply: basic insulation according to EN 50178, rated insulation voltage 253 Veff
Display elements: LEDs
Control elements: DIP-switch potentiometer
Configuration: via DIP switches via potentiometer
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2004/108/EC: EN 61326-1:2006
Low voltage: Directive 2006/95/EC: EN 50178:1997
Insulation coordination: EN 50178:1997
Galvanic isolation: EN 50178:1997
Electromagnetic compatibility: NE 21:2006
Degree of protection: IEC 60529:2001
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals , max. 2.5 mm2
Mass: approx. 150 g
Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Logistic parameters

ECCN:
Country of Origin: SG
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m