215316
PMI360DV-F130-IU2E2-V15
Ind. angular measuring system
Analog output, load-dependent voltage or current, 2 configurable switching frames, Parameterisable measuring rangefa
| Measurement range: | max. 360° min. 45° |
| Adjustment range: | 2 switch frames programmable , min. 5°, max. 360° |
| Rotational speed: | max. 100 min-1 |
| Operating voltage: | 18 ... 30 V DC |
| Reverse polarity protection: | reverse polarity protected |
| Repeat accuracy: | ± 0.25 ° |
| Resolution: | 0.2 ° |
| Temperature drift: | 0.02 ° / °C (-25 °C ... 70 °C) |
| No-load supply current: | ≤ 45 mA |
| MTTFd: | 450 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| LED yellow 1: | switching state, Switching output 1 |
| LED yellow 2: | switching state, Switching output 2 |
| LED PWR/ERR: | Status display LED, green/red (Power on / missing actuator / keylock) |
| LED U/I: | Activator within measuring range |
| Output type: | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable |
| Operating current: | ≤ 100 mA |
| Switching hysteresis: | 1 ° |
| Voltage drop: | ≤ 3 V |
| Short-circuit protection: | pulsing |
| Output type: | current output or voltage output (load dependend) 4 ... 20 mA (RL < 400 Ω) 0 ... 10 V (RL > 3.3 kΩ) |
| Linearity error: | ± 0.6 ° , (with original actuator) |
| Standard conformity: Standards: | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| UL approval: | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Connection type: | 5-pin, M12 x 1 connector |
| Degree of protection: | IP67 |
| Material: Housing: | PBT |
| Material: Target: | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Mass: | 180 g |
| ECCN: | |
| Country of Origin: | SG |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |