Analog output, load-dependent voltage or current, Parameterisable measuring rangefa

Technical parameters

Measurement range: max. 360° min. 45°
Adjustment range: 360°
Rotational speed: max. 100 min-1
Operating voltage: 18 ... 30 V DC
Reverse polarity protection: reverse polarity protected
Repeat accuracy: ± 0.25 °
Resolution: 0.2 °
Temperature drift: 0.02 ° / °C (-25 °C ... 70 °C)
No-load supply current: ≤ 45 mA
MTTFd: 450 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
LED PWR/ERR: LED green / red
LED U/I: Activator within measuring range
Output type: current output or voltage output (load dependend) 4 ... 20 mA (RL < 400 Ω) 0 ... 10 V (RL > 3.3 kΩ)
Linearity error: ± 0.6 ° , (with original actuator)
Standard conformity: Standards: EN 60947-5-2:2007 IEC 60947-5-2:2007
UL approval: cULus Listed, General Purpose, Class 2 Power Source
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: -25 ... 70 °C (-13 ... 158 °F)
Connection type: 5-pin, M12 x 1 connector
Degree of protection: IP67
Material: Housing: PBT
Material: Target: mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Mass: 180 g

Logistic parameters

ECCN:
Country of Origin: SG
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m