Pepperl+Fuchs 214740

KC-LCDC-48-2R-230VAC

Timer, Counter, Tachometer

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 2 pre-selections, Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs, Multicolor displayfa

Technical parameters

Pre-selection: 2-fold
Data storage: > 10 years, EEPROM
Programming: keypad-driven menu
MTTFd: 410 a
Mission Time (TM): 10 a
Diagnostic Coverage (DC): 0 %
Type: 2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit
Display value: digit height 9 mm
Pre-selection: digit height 7 mm
Key interlock: via "high" potential at "LOCK" input
Decimal point: 0 to max 5 fractional digits
Scale factor: 0.0001 ... 99.9999
Reset: manually or external
Fusing: 90 … 260 V AC: T 0.1 A
Operating voltage: 90 ... 260 V AC
Power consumption: max. 8 VA
Connection: Counter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI
Signal voltage: High: 12 ... 30 V DC
Signal voltage: Low: 0 ... 4 V DC
Counting frequency: 30 Hz / 55 kHz
Minimum pulse duration: Control/reset inputs: 10 ms / 1 ms
Impedance: 5 kOhm
Count modes: Pulse counter: Counting with counting direction (cnt.dir), difference counting (up.dn), up/down counting (quad), Cumulative counting (up.up), up/down counting x 2 (quad 2), up/down counting x 4 (quad 4), additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%
Count modes: Frequency counter: functions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 %
Count modes: Timer: Time measurement via GATE input (FrErun), counter input A: Start, counter input B: Stop (InpA.InpB.), counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto)
Relay: changeover contact , Make contact
Count modes: Switching voltage: max. 250 V AC / 110 V DC
Count modes: Switching current: max. 3 A AC/DC, min. 30 mA DC,
Count modes: Switching power: max. 750 VA / 90 W
Sensor supply: 20.4 ... 27.6 V DC, max. 80 mA
Output I: Relay with make contact, NC or NO progr.
Count modes: Mechanical life: 2 x 107 switching cycles
Count modes: Electrical life: 1 x 105 switching cycles at 3 A
Output II: Relay with changeover contact
Count modes: Mechanical life: 2 x 107 switching cycles
Count modes: Electrical life: 5 x 104 cycles at 3 A
Response time: Relay: approx. 7 ms Frequency counter: 100/600 ms
Directive conformity: Low Voltage Directive 2006/95/EC: EN 61010-1:2001; protection class: 2
Directive conformity: EMC Directive 2004/108/EC: EN 61000-6-2:2005, EN 50295:1999
Standard conformity: Emitted interference: DIN EN 55011:2009, Class B
Standard conformity: Mech. capacity: EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction
Standard conformity: Shock and impact resistance: EN 60068-2-27:1995 100 G / 2 ms / XYZ 3 times in each direction
Ambient temperature: -20 ... 65 °C (-4 ... 149 °F)
Storage temperature: -25 ... 75 °C (-13 ... 167 °F)
Relative humidity: ≤ 93 % at 40 °C (noncondensing)
Altitude: 0 ... 2000 m
Pollution degree: 2
Degree of protection: IP65 (front)
Mass: approx. 142 g
Dimensions: 48 mm x 48 mm x 109.8 mm

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.00 kg
Length: 0.00 m
Width: 0.00 m