214735
KC-LCD-48-1R-24VDC
Timer, Counter
Counter/Timer, Adding/subtracting via 2 separate inputs, Batch controller with 1 pre-selection, Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status, Display range and preselection range from -999999 up to 999999. Overflow will be evaluated correctly up to 1 decadefa
| Pre-selection: | single |
| Data storage: | > 10 years, EEPROM |
| Programming: | keypad-driven menu |
| Type: | 2-line, 2 x 6-digit LC display with leading sign |
| Display value: | digit height 9 mm |
| Pre-selection: | digit height 7 mm |
| Key interlock: | via "high" potential at "LOCK" input |
| Decimal point: | 0 to max 5 fractional digits |
| Scale factor: | 0.0001 ... 99.9999 |
| Reset: | manually or external |
| Fusing: | 11 … 30 V DC: T 0.2 A |
| Operating voltage: | 11 ... 30 V DC |
| Power consumption: | max. 4 W |
| Connection: | Counter inputs: A and B Control/reset inputs: LOCK, RESET |
| Signal voltage: High: | 3.5 ... 30 V DC |
| Signal voltage: Low: | 0 ... 2 V DC |
| Counting frequency: | 30 Hz / 5 kHz |
| Minimum pulse duration: | Control/reset inputs: static / 1 ms |
| Impedance: | 10 kOhm |
| Count modes: Pulse counter: | Counting with counting direction (cnt.dir), difference counting (up.dn), up/down counting (quad), |
| Count modes: Timer: | Time measurement via GATE input (FrErun), counter input A: Start, counter input B: Stop (InpA.InpB.), counter input B: Start/Stop (InpB.InpB.), |
| Relay: | changeover contact |
| Count modes: Switching voltage: | max. 250 V AC / 110 V DC |
| Count modes: Switching current: | max. 3 A AC/DC, min. 30 mA DC, |
| Count modes: Switching power: | max. 750 VA / 90 W |
| Count modes: Mechanical life: | 2 x 107 switching cycles |
| Count modes: Electrical life: | 5 x 104 cycles at 3 A |
| Count modes: Response time: | < 15 ms pulse counter < 10 ms time counter |
| Sensor supply: | connected power supply is looped through, max. 50 mA |
| Directive conformity: EMC Directive 2004/108/EC: | EN 61000-6-2:2005, EN 50295:1999 |
| Standard conformity: Emitted interference: | DIN EN 55011:2009, Class B |
| Standard conformity: Mech. capacity: | EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction |
| Standard conformity: Shock and impact resistance: | EN 60068-2-27:1995 100 G / 2 ms / XYZ 3 times in each direction |
| Ambient temperature: | -10 ... 50 °C (14 ... 122 °F) |
| Storage temperature: | -25 ... 75 °C (-13 ... 167 °F) |
| Relative humidity: | ≤ 93 % at 40 °C (noncondensing) |
| Altitude: | 0 ... 2000 m |
| Degree of protection: | IP65 (front) |
| Mass: | approx. 117 g |
| Dimensions: | 48 mm x 48 mm x 109.8 mm |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |