204536
UB1000-18GM75-U-V15
Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Measuring window adjustable, Selectable sound lobe width, Series: -18GM, Housing: brass, nickel-plated, Connection type: Connector plug M12 x 1 , 5-pinfa
| Sensing range: | 70 ... 1000 mm |
| Adjustment range: | 90 ... 1000 mm |
| Dead band: | 0 ... 70 mm |
| Standard target plate: | 100 mm x 100 mm |
| Transducer frequency: | approx. 255 kHz |
| Response delay: | approx. 125 ms |
| LED yellow: | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
| LED red: | solid red: Error red, flashing: program function, object not detected |
| Operating voltage: | 15 ... 30 V DC , ripple 10 %SS |
| No-load supply current: | ≤ 50 mA |
| Synchronization: | 1 synchronous connection, bi-directional 0-level: -UB...+1 V 1-level: +4 V...+UB input impedance: > 12 kΩ synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
| Synchronization frequency: Common mode operation: | max. 40 Hz |
| Synchronization frequency: Multiplex operation: | ≤ 40 Hz / n, n = number of sensors, n ≤ 5 |
| Input type: | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
| Output type: | 1 analog output 0 ... 10 V |
| Resolution: | 0.35 mm |
| Deviation of the characteristic curve: | ± 1 % of full-scale value |
| Repeat accuracy: | ± 0.1 % of full-scale value |
| Load impedance: | > 1 kOhm |
| Temperature influence: | ± 1.5 % of full-scale value |
| Standard conformity: Standards: | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| UL approval: | cULus Listed, General Purpose |
| CSA approval: | cCSAus Listed, General Purpose |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Connection type: | Connector plug M12 x 1 , 5-pin |
| Degree of protection: | IP67 |
| Material: Housing: | brass, nickel-plated |
| Material: Transducer: | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Mass: | 60 g |
| Output: | evaluation limit A1: 90 mm evaluation limit A2: 1000 mm output function: rising ramp |
| Beam width: | wide |
| ECCN: | |
| Country of Origin: | SG |
| EAN: | |
| Weight: | 0.00 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |